Extraction of cadmium and copper using hollow fiber supported liquid membranes

被引:80
|
作者
Breembroek, GRM [1 ]
van Straalen, A [1 ]
Witkamp, GJ [1 ]
van Rosmalen, GM [1 ]
机构
[1] Delft Univ Technol, Lab Proc Equipment, NL-2628 CA Delft, Netherlands
关键词
supported liquid membrane; extraction; hollow fiber; copper; cadmium;
D O I
10.1016/S0376-7388(98)00099-4
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Copper, cadmium and lead were extracted through a hollow fiber supported liquid membrane with Lix 84-i as copper extractant and Alamine 304-i as extractant for cadmium and lead. The mass transfer rate, expressed as permeability P, was limited by the diffusion through the aqueous stagnant films in the module for copper extraction. A characteristic permeability of 6.9x10(-6) ms(-1) was measured at a flow rate of 0.076 m s(-1) through the fibers. The measured permeabilities were compared to generally accepted mass transfer correlations. For a feed flowing on the tube side, these correlations predicted a three times higher permeability than was measured, while at the shell side, the permeabilities predicted from these accepted correlations were up to a factor of 8 lower than the measured ones. The extraction rate of cadmium from chloride solutions was limited by membrane diffusion. At 0.2 M Alamine 304-i, a permeability of 4.10(-6) m s(-1) was measured. Higher extraction rates were found when cadmium was extracted from chloride-containing mixtures of phosphoric and sulfuric acid. The extraction rate of lead was a factor of 20 lower than that of cadmium. This was due to the fact that the extractant had a lower affinity for lead. (C) 1998 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 50 条
  • [1] COPPER EXTRACTION FROM DILUTED SOLUTIONS USING HOLLOW FIBER SUPPORTED LIQUID MEMBRANES
    Caltaru, Mihaela
    Petrescu, Nicolae
    Vasiliu, Cristina
    JOURNAL OF MINING INSTITUTE, 2006, 167 (02): : 135 - 138
  • [2] Separation of actinides using hollow fiber supported liquid membranes
    Ansari, S. A.
    Bhattacharyya, A.
    Raut, D. R.
    Mohapatra, P. K.
    Manchanda, V. K.
    RADIOCHIMICA ACTA, 2009, 97 (03) : 149 - 153
  • [3] THEORETICAL-ANALYSIS OF COPPER-ION EXTRACTION THROUGH HOLLOW-FIBER SUPPORTED LIQUID MEMBRANES
    SHIAU, CY
    CHEN, PZ
    SEPARATION SCIENCE AND TECHNOLOGY, 1993, 28 (13-14) : 2149 - 2165
  • [4] Modeling and simulation of copper-ion extraction with hollow fiber supported liquid membrane
    Vittisupakorn, Paisan
    Weerachaipichaskul, Weerawun
    Thitiyasook, Piyanuch
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2007, 13 (06) : 903 - 910
  • [5] Simultaneous Extraction of Neodymium and Uranium using Hollow Fiber Supported Liquid Membrane
    Vernekar, Prasad V.
    Jagdale, Yogesh D.
    Sharma, Ajay D.
    Patwardhan, AshwinW.
    Patwardhan, Anand V.
    Ansari, Seraj A.
    Mohapatra, Prasanta K.
    SEPARATION SCIENCE AND TECHNOLOGY, 2014, 49 (10) : 1509 - 1520
  • [6] Failure Mechanisms of Hollow Fiber Supported Ionic Liquid Membranes
    Zeh, Matthew
    Wickramanayake, Shan
    Hopkinson, David
    MEMBRANES, 2016, 6 (02):
  • [8] HOLLOW-FIBER SUPPORTED LIQUID MEMBRANES FOR THE EXTRACTION OF PENICILLINS AND THE SYNTHESIS OF 6-AMINOPENICILLANIC ACID
    TSIKAS, D
    KALTSIDOUSCHOTTELIUS, E
    BRUNNER, G
    CHEMIE INGENIEUR TECHNIK, 1992, 64 (06) : 545 - 548
  • [9] The Transport of Copper(II) through Hollow Fiber Renewal Liquid Membrane and Hollow Fiber Supported Liquid Membrane
    Ren, Zhongqi
    Meng, Huilin
    Zhang, Weidong
    Liu, Junteng
    Cui, Chunhua
    SEPARATION SCIENCE AND TECHNOLOGY, 2009, 44 (05) : 1181 - 1197
  • [10] EXTRACTION WITH EMULSION LIQUID MEMBRANES IN A HOLLOW-FIBER CONTACTOR
    RAGHURAMAN, B
    WIENCEK, J
    AICHE JOURNAL, 1993, 39 (11) : 1885 - 1889