Continuous simultaneous detection in mass Spectrometry

被引:51
作者
Schilling, Gregory D.
Andrade, Francisco J.
Barnes, James H.
Sperline, Roger P.
Denton, M. Bonner
Barinaga, Charles J.
Koppenaal, David W.
Hieftje, Gary M. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[3] Univ Arizona, Dept Chem, Tucson, AZ 85721 USA
[4] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac070785s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously and continuously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.
引用
收藏
页码:7662 / 7668
页数:7
相关论文
共 36 条
[1]   Simultaneous multichannel mass-specific detection for high-performance liquid chromatography using an array detector sector-field mass spectrometer [J].
Barnes, JH ;
Schilling, GD ;
Stone, SF ;
Sperline, RP ;
Denton, MB ;
Young, ET ;
Barinaga, CJ ;
Koppenaal, DW ;
Hieftje, GM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (02) :227-234
[2]   Recent advances in detector-array technology for mass spectrometry [J].
Barnes, JH ;
Hieftje, GM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 238 (01) :33-46
[3]   Coupling of a gas chromatograph to a simultaneous-detection inductively coupled plasma mass spectrograph for speciation of organohalide and organometallic compounds [J].
Barnes, JH ;
Schilling, GD ;
Sperline, RP ;
Denton, MB ;
Young, ET ;
Barinaga, CJ ;
Koppenaal, DW ;
Hieftje, GM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (06) :751-756
[4]   Use of a novel array detector for the direct analysis of solid samples by laser ablation inductively coupled plasma sector-field mass spectrometry [J].
Barnes, JH ;
Schilling, GD ;
Hieftje, GM ;
Sperline, RP ;
Denton, MB ;
Barinaga, CJ ;
Koppenaal, DW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (06) :769-776
[5]   Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 2. Use with an inductively coupled plasma [J].
Barnes, JH ;
Schilling, GD ;
Sperline, R ;
Denton, MB ;
Young, ET ;
Barinaga, CJ ;
Koppenaal, DW ;
Hieftje, GM .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2531-2536
[6]   Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source [J].
Barnes, JH ;
Sperline, R ;
Denton, MB ;
Barinaga, CJ ;
Koppenaal, D ;
Young, ET ;
Hieftje, GM .
ANALYTICAL CHEMISTRY, 2002, 74 (20) :5327-5332
[7]  
Barshick C., 2000, Inorganic Mass Spectrometry: Fundamentals and Applications
[8]   Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Udseth, HR ;
Conrads, TP ;
Veenstra, TD ;
Masselon, CD ;
Gorshkov, MV ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :253-261
[9]   Forensic applications of isotope ratio mass spectrometry - A review [J].
Benson, S ;
Lennard, C ;
Maynard, P ;
Roux, C .
FORENSIC SCIENCE INTERNATIONAL, 2006, 157 (01) :1-22
[10]   Effects of crater development on fractionation and signal intensity during laser ablation inductively coupled plasma mass spectrometry [J].
Borisov, OV ;
Mao, XL ;
Russo, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (11) :1693-1704