A predictive model for early diagnosis of keratoconus

被引:21
作者
Castro-Luna, Gracia [1 ]
Perez-Rueda, Antonio [2 ]
机构
[1] Univ Almeria, Dept Nursing Physiotherapy & Med, Almeria, Spain
[2] Torrecardenas Univ Hosp, UGC Ophthalmol, Almeria, Spain
关键词
Keratoconus; Corneal topography; High order aberrations; Coma; SCHEIMPFLUG IMAGING PARAMETERS; ANTERIOR CORNEAL ABERRATIONS; HIGHER-ORDER ABERRATIONS; SUBCLINICAL KERATOCONUS; FELLOW EYES; POSTERIOR; TOMOGRAPHY; THICKNESS; INDEXES; SURFACE;
D O I
10.1186/s12886-020-01531-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundThe diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore, to avoid possible refractive surgery that could produce ectasias. This study aims to describe the topographic, pachymetric and aberrometry characteristics in patients with keratoconus, subclinical keratoconus and normal corneas. Additionally to propose a diagnostic model of subclinical keratoconus based in binary logistic regression models.MethodsThe design was a cross-sectional study. It included 205 eyes from 205 patients distributed in 82 normal corneas, 40 early-stage keratoconus and 83 established keratoconus. The rotary Scheimpflug camera (Pentacam (R) type) analyzed the topographic, pachymetric and aberrometry variables. It performed a descriptive and bivariate analysis of the recorded data. A diagnostic and predictive model of early-stage keratoconus was calculated with the statistically significant variables.ResultsStatistically significant differences were observed when comparing normal corneas with early-stage keratoconus/ in variables of the vertical asymmetry to 90 degrees and the central corneal thickness. The binary logistic regression model included the minimal corneal thickness, the anterior coma to 90 degrees and posterior coma to 90 degrees. The model properly diagnosed 92% of cases with a sensitivity of 97.59%, specificity 98.78%, accuracy 98.18% and precision 98.78%.ConclusionsThe differential diagnosis between normal cases and subclinical keratoconus depends on the minimum corneal thickness, the anterior coma to 90 degrees and the posterior coma to 90 degrees.
引用
收藏
页数:9
相关论文
共 45 条
[41]   Keratoconus Screening Indices and Their Diagnostic Ability to Distinguish Normal From Ectatic Corneas [J].
Shetty, Rohit ;
Rao, Harsha ;
Khamar, Pooja ;
Sainani, Kanchan ;
Vunnava, Krishnapoojita ;
Jayadev, Chaitra ;
Kaweri, Luci .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 181 :140-148
[42]   Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes [J].
Steinberg, Johannes ;
Aubke-Schultz, Silke ;
Frings, Andreas ;
Huelle, Jan ;
Druchkiv, Vasyl ;
Richard, Gisbert ;
Katz, Toam ;
Linke, Stephan J. .
ACTA OPHTHALMOLOGICA, 2015, 93 (03) :e199-e207
[43]   A review of keratoconus: Diagnosis, pathophysiology, and genetics [J].
Tur, Veronica Mas ;
MacGregor, Cheryl ;
Jayaswal, Rakesh ;
O'Brart, David ;
Maycock, Nicholas .
SURVEY OF OPHTHALMOLOGY, 2017, 62 (06) :770-783
[44]   Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes [J].
Ucakhan, Omur O. ;
Cetinkor, Volkan ;
Ozkan, Muhip ;
Kanpolat, Ayfer .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) :1116-1124
[45]   Climate variability and trends at a national scale [J].
Xu, Zhenci ;
Tang, Ying ;
Connor, Thomas ;
Li, Dapeng ;
Li, Yunkai ;
Liu, Jianguo .
SCIENTIFIC REPORTS, 2017, 7