The sloshing effects on distribution characteristics of gas-liquid mixture in spiral-wound heat exchanger

被引:3
作者
Zheng, Wenke [1 ,2 ]
Jiang, Yiqiang [1 ,2 ]
Wang, Yue [3 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Harbin 150090, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement E, Harbin 150001, Peoples R China
[3] Northeast Elect Power Univ, Sch Energy & Power Engn, Jilin 132012, Jilin, Peoples R China
关键词
FPSO; SWHE; Sloshing conditions; Distribution characteristics; Two-phase flow; 2-PHASE FLOW DISTRIBUTION; DISTRIBUTION PERFORMANCE; SHELL-SIDE; HYDROCARBON MIXTURES; PRESSURE-DROP; COMPACT; CONDENSATION; HEADER; NANOFLUIDS; ENTRANCE;
D O I
10.1007/s10973-020-09423-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Spiral-wound heat exchanger (SWHE) is important equipment for industry, and it is suitable for floating production storage off-loading (FPSO). However, two-phase mixture maldistribution always restricts the heat transfer capacity of SWHE in FPSO. Few studies have focused on the maldistribution of SWHE. According to this, an experimental device was fabricated to evaluate the maldistribution of a novel distributor on the sloshing platform. The effects of vapor qualities and mass flow rates were analyzed at the range of 0.106-0.702 and 608.5-1491.6 kg h(-1), respectively. The following conclusions are drawn: With the augmentation of vapor quality, the gas-liquid uniformity deteriorates after optimizing under steady and sloshing conditions. Heave condition improves gas and liquid flow uniformity by 2.9-11.0% and 1.7-3.7% separately, and pitch condition improves the gas flow uniformity by 0.5-3.7%, and roll condition lowers the liquid flow uniformity by 2.0-7.2% in the variation of vapor quality. It is also proved that the flow uniformity achieves better performance with the increasing mass flow rate under steady, heave and pitch conditions. Heave condition improves the distribution characteristic by 4.4-8.7% for the gas phase and 2.0-9.5% for the liquid phase, and pitch condition elevates the gas flow uniformity by 3.1-7.7%. Under the roll condition, the distribution performance of the experimental model changes worse after better and obtains the best performance at the mass flow rate of 1183.8 kg/h. At large mass flow rates, gas entering into liquid space under roll condition can bring the structural problem. Increasing the tube diameter and making the upper baffle tilt from shell to center barrel are beneficial to keep the distributor structure safe.
引用
收藏
页码:599 / 612
页数:14
相关论文
共 32 条
  • [1] CFD and experimental investigation of the gas-liquid flow in the distributor of a compact heat exchanger
    Ben Saad, Selma
    Gentric, Caroline
    Fourmigue, Jean-Francois
    Clement, Patrice
    Leclerc, Jean-Pierre
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2014, 92 (11) : 2361 - 2370
  • [2] Single phase pressure drop and two-phase distribution in an offset strip fin compact heat exchanger
    Ben Saad, Selma
    Clement, Patrice
    Fourmigue, Jean-Francois
    Gentric, Caroline
    Leclerc, Jean-Pierre
    [J]. APPLIED THERMAL ENGINEERING, 2012, 49 : 99 - 105
  • [3] Experimental distribution of phases and pressure drop in a two-phase offset strip fin type compact heat exchanger
    Ben Saad, Selma
    Clement, Patrice
    Gentric, Caroline
    Fourmigue, Jean-Francois
    Leclerc, Jean-Pierre
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2011, 37 (06) : 576 - 584
  • [4] PERFORMANCE OF A COMPACT, SPIRAL COIL HEAT-EXCHANGER
    HO, JC
    WIJEYSUNDERA, NE
    RAJASEKAR, S
    CHANDRATILLEKE, TT
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (05): : 457 - 468
  • [5] Study of a compact spiral-coil cooling and dehumidifying heat exchanger
    Ho, JC
    Wijeysundera, NE
    [J]. APPLIED THERMAL ENGINEERING, 1996, 16 (10) : 777 - 790
  • [6] Heat transfer characteristics of two-phase mixed hydrocarbon refrigerants flow boiling in shell side of LNG spiral wound heat exchanger
    Hu, Haitao
    Ding, Chao
    Ding, Guoliang
    Chen, Jie
    Mi, Xiaoguang
    Yu, Sicong
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 131 : 611 - 622
  • [7] Numerical study on condensation heat transfer and pressure drop characteristics of ethane/propane mixture upward flow in a spiral pipe
    Li, Shulei
    Cai, Weihua
    Chen, Jie
    Zhang, Haochun
    Jiang, Yiqiang
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 121 : 170 - 186
  • [8] Numerical study on the flow and heat transfer characteristics of forced convective condensation with propane in a spiral pipe
    Li, Shulei
    Cai, Weihua
    Chen, Jie
    Zhang, Haochun
    Jiang, Yiqiang
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 1169 - 1187
  • [9] Sloshing resistance and gas-liquid distribution performance in the entrance of LNG plate-fin heat exchangers
    Li, Yan
    Li, Yuxing
    Hu, Qihui
    Wang, Wuchang
    Xie, Bin
    Yu, Xichong
    [J]. APPLIED THERMAL ENGINEERING, 2015, 82 : 182 - 193
  • [10] Experiments on two-phase flow distribution inside parallel channels of compact heat exchangers
    Marchitto, A.
    Devia, F.
    Fossa, M.
    Guglielmini, G.
    Schenone, C.
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2008, 34 (02) : 128 - 144