Step-by-Step Aortic Valve Replacement With a New Rapid Deployment Valve

被引:13
作者
Accola, Kevin D. [1 ]
Chitwood, W. Randolph, Jr.
Mumtaz, Mubashir A.
Barnhart, Glenn R.
机构
[1] Florida Hosp, Valve Ctr Excellence, Cardiovasc Inst, 217 Hillcrest St, Orlando, FL 32801 USA
关键词
EXPERIENCE; OUTCOMES; INTUITY;
D O I
10.1016/j.athoracsur.2017.08.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. Rapid deployment/sutureless aortic valve replacement is aimed at minimizing the invasiveness of surgical aortic valve replacement. We describe the implantation techniques of a new rapid deployment aortic valve, focusing on its unique and challenging features. Description. The EDWARDS INTUITY Elite aortic valve (Edwards Lifesciences, Irvine, CA) represents a hybrid between the surgical PERIMOUNT Magna Ease (Edwards Lifesciences) pericardial valve, but with advanced features of the percutaneous SAPIEN valve system (Edwards Lifesciences). A flexible delivery system, with a balloon-expandable subannular frame, facilitates insertion. Important implantation steps include an extended oblique "hockey-stick" aortotomy, symmetrical annular debridement, intra-annular and supra-annular sizing, guiding suture placement, and balloon expansion of the subannular valve frame. Evaluation. Although this valve provides advantages over conventional aortic valves, its implantation is unique, and special operative considerations must be heeded for optimal outcomes. Implantation requires minimal suturing, enabling smaller incisions. Also, the intra-annular inflow frame may promote improved hemodynamics. Conclusions. The INTUITY Elite system represents a significant innovation in bio-prosthesis technology. It has been shown to be safe and effective, but its implantation requires detailed attention to several unique operative steps. (C) 2018 by The Society of Thoracic Surgeons
引用
收藏
页码:966 / 971
页数:6
相关论文
共 10 条
[1]   Conventional versus rapid-deployment aortic valve replacement: a single-centre comparison between the Edwards Magna valve and its rapid-deployment successor [J].
Andreas, Martin ;
Wallner, Stephanie ;
Habertheuer, Andreas ;
Rath, Claus ;
Schauperl, Martin ;
Binder, Thomas ;
Beitzke, Dietrich ;
Rosenhek, Raphael ;
Loewe, Christian ;
Wiedemann, Dominik ;
Kocher, Alfred ;
Laufer, Guenther .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (06) :799-805
[2]   TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve [J].
Barnhart, Glenn R. ;
Accola, Kevin D. ;
Grossi, Eugene A. ;
Woo, Y. Joseph ;
Mumtaz, Mubashir A. ;
Sabik, Joseph F. ;
Slachman, Frank N. ;
Patel, Himanshu J. ;
Borger, Michael A. ;
Garrett, H. Edward, Jr. ;
Rodriguez, Evelio ;
McCarthy, Patrick M. ;
Ryan, William H. ;
Duhay, Francis G. ;
Mack, Michael J. ;
Chitwood, W. Randolph, Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (02) :241-+
[3]   Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trialaEuro [J].
Borger, Michael A. ;
Dohmen, Pascal M. ;
Knosalla, Christoph ;
Hammerschmidt, Robert ;
Merk, Denis R. ;
Richter, Markus ;
Doenst, Torsten ;
Conradi, Lenard ;
Treede, Hendrik ;
Moustafine, Vadim ;
Holzhey, David M. ;
Duhay, Francis ;
Strauch, Justus .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (04) :713-720
[4]   Conduction Disorders After Sutureless Aortic Valve Replacement [J].
Bouhout, Ismail ;
Mazine, Amine ;
Rivard, Lena ;
Ghoneim, Aly ;
El-Hamamsy, Ismail ;
Lamarche, Yoan ;
Carrier, Michel ;
Demers, Philippe ;
Bouchard, Denis .
ANNALS OF THORACIC SURGERY, 2017, 103 (04) :1254-1261
[5]   Very Long-Term Outcomes of the Carpentier-Edwards Perimount Valve in Aortic Position [J].
Bourguignon, Thierry ;
Bouquiaux-Stablo, Anne-Lorraine ;
Candolfi, Pascal ;
Mirza, Alain ;
Loardi, Claudia ;
May, Marc-Antoine ;
El-Khoury, Rym ;
Marchand, Michel ;
Aupart, Michel .
ANNALS OF THORACIC SURGERY, 2015, 99 (03) :831-837
[6]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA) [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Lluis ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Luis Zamorano, Jose ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hector ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Luis Tamargo, Juan ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Baensch, Dietmar ;
Baumgartner, Helmut .
EUROPEAN HEART JOURNAL, 2013, 34 (29) :2281-2329
[7]   The sutureless aortic valve at 1 year: A large multicenter cohort study [J].
Fischlein, Theodor ;
Meuris, Bart ;
Hakim-Meibodi, Kavous ;
Misfeld, Martin ;
Carrel, Thierry ;
Zembala, Marian ;
Gaggianesi, Sara ;
Madonna, Francesco ;
Laborde, Francois ;
Asch, Federico ;
Haverich, Axel .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (06) :1617-+
[8]   Long-term outcomes of a rapid deployment aortic valve: data up to 5 years [J].
Laufer, Guenther ;
Haverich, Axel ;
Andreas, Martin ;
Mohr, Friedrich W. ;
Walther, Thomas ;
Shrestha, Malakh ;
Rahmanian, Parwis ;
Holzhey, David ;
Roth, Matthias ;
Schmitz, Christoph ;
Schramm, Rene ;
Giot, Christophe ;
Wahlers, Thorsten C. W. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (02) :281-287
[9]   The economic value of INTUITY in aortic valve replacement [J].
Moore, Matthew ;
Barnhart, Glenn R. ;
Chitwood, Walter Randolph, Jr. ;
Rizzo, John A. ;
Gunnarsson, Candace ;
Palli, Swetha R. ;
Grossi, Eugene A. .
JOURNAL OF MEDICAL ECONOMICS, 2016, 19 (10) :1011-1017
[10]   Minimal access rapid deployment aortic valve replacement: Initial single-center experience and 12-month outcomes [J].
Schloemicher, Markus ;
Haldenwang, Peter Lukas ;
Moustafine, Vadim ;
Bechtel, Matthias ;
Strauch, Justus Thomas .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (02) :434-440