Retrospective study of post-operative infections in implantable cardiac devices in a cardiac tertiary care center

被引:2
作者
Atig, Alamer Modi [1 ]
Alhamad, Yara Ibrahim [1 ]
Alanizi, Foz Salem [2 ]
Ardah, Husam Ismail [3 ]
Alanazi, Haitham [2 ]
机构
[1] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Med, Riyadh 11426, Saudi Arabia
[2] King Abdul Aziz Med City, Cardiac Cath Lab, Riyadh, Saudi Arabia
[3] King Saud Bin Abdulaziz Univ Hlth Sci, Dept Biostat & Bioinformat, Riyadh, Saudi Arabia
关键词
CARDIOVERTER-DEFIBRILLATORS; RISK-FACTORS; PACEMAKER; MANAGEMENT; SOCIETY; TRENDS;
D O I
10.5144/0256-4947.2022.58
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The rise in the incidence of implantation is one of the main causes behind the increased rate of CIED infection, which is considered as a serious life-threatening complication.The need of risk factor assessment has become a necessity to prevent further complica-tions and provide prompt management OBJECTIVES: Identify the risk factors of infection postoperatively among patients who have implantable cardiac devices. DESIGN: A retrospective case-control study. SETTINGS: Cardiac center for adults PATIENTS AND METHODS: The study included all adult patients ( >= 14 years of age ) of all nationalities who underwent cardiac electronic device implantation that was managed in the cardiac center between January 2012 to December 2018. MAIN OUTCOME MEASURES: Cardiac device infection and associ-ated risk factors. SAMPLE SIZE: 213, including 23 (10.8%) infected case patients and 190 (89.2%) non-infected controls. RESULTS: The mean (SD) age of non-infected patients was 45.0 (12.7) years compared with 61.7 (13.7) for infected patients (P<.0001). Anticoagulant use, hypertension, dysplipdemia and age were the most common patient-related risk factors associated with infection. For pro-cedural and post-procedural risk factors, the risk of infection increased as the number of leads and length of procedure increased. The device most often related to infection was the pacemaker. In the multivariate analysis, longer procedure, greater number of leads, older age, anti-coagulant use, and implanted pacemaker device were independently associated with infection. CONCLUSION: We advise the prompt use of strict preoperative an-tiseptic prophylaxis measures and follow-up for post-implant patients along with patient education for early signs of infections, which will lead to improvement of both diagnosis and treatment quality for our patients in addition to reducing the economic impact on the health care system by minimizing infectious complications.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 50 条
[21]   Cardiac implantable electronic device surgery with interruption of warfarin forgoing post-operative bridging therapy in patients with moderate or high thromboembolic risks [J].
Ng, Andrew Kei-Yan ;
Ng, Pauline Yeung ;
Tam, Eva Wai-Ying ;
Siu, Chung-Wah ;
Fan, Katherine .
THROMBOSIS JOURNAL, 2021, 19 (01)
[22]   Biomarkers in infections related to cardiac implantable electronic devices [J].
Lennerz, Carsten ;
O'Connor, Matthew .
KARDIOLOGIA POLSKA, 2019, 77 (10) :897-898
[23]   Therapy and outcomes of cardiac implantable electronic devices infections [J].
Perrin, Tilman ;
Deharo, Jean-Claude .
EUROPACE, 2021, 23 :20-27
[24]   Infections Associated with Cardiac Implantable Electronic Devices Are Misunderstood [J].
Wilkoff, Bruce L. .
TEXAS HEART INSTITUTE JOURNAL, 2011, 38 (04) :353-354
[25]   Pocket infections of cardiac implantable electronic devices treated by negative pressure wound therapy [J].
McGarry, Thomas J. ;
Joshi, Rajeev ;
Kawata, Hiro ;
Patel, Jigar ;
Feld, Gregory ;
Birgersdotter-Green, Ulrika M. ;
Pretorius, Victor .
EUROPACE, 2014, 16 (03) :372-377
[26]   Infections of cardiac implantable electronic devices: Epidemiology, mechanisms, and preventive measures [J].
Traykov, Vassil ;
Dzhinsov, Krasimir ;
Matusik, Pawel .
KARDIOLOGIA POLSKA, 2023, 81 (09) :859-869
[27]   Burden of disease and costs of infections associated with cardiac implantable electronic devices [J].
Sgreccia, Daria ;
Vitolo, Marco ;
Valenti, Anna Chiara ;
Manicardi, Marcella ;
Boriani, Giuseppe .
EXPERT REVIEW OF PHARMACOECONOMICS & OUTCOMES RESEARCH, 2022, 22 (01) :7-16
[28]   Cardiac Implantable Electronic Devices and End-of-Life Care: An Australian Perspective [J].
Alhammad, Nasser J. ;
O'Donnell, Mark ;
O'Donnell, David ;
Mariani, Justin A. ;
Gould, Paul A. ;
McGavigan, Andrew D. .
HEART LUNG AND CIRCULATION, 2016, 25 (08) :814-819
[29]   Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study [J].
Ahmed, Fozia Zahir ;
Fullwood, Catherine ;
Zaman, Mahvash ;
Qamruddin, Ahmed ;
Cunnington, Colin ;
Mamas, A. Mamas ;
Sandoe, Jonathan ;
Motwani, Manish ;
Zaidi, Amir .
PLOS ONE, 2019, 14 (01)
[30]   Neurosurgical Post-Operative Wound Infections: A retrospective study on surgical site infections for quality improvement [J].
Fiani, Brian ;
Cathel, Alessandra ;
Sarhadi, Kasra J. ;
Cohen, Jordan ;
Siddiqi, Javed .
INTERNATIONAL WOUND JOURNAL, 2020, 17 (04) :1039-1046