Synthetic Time of Flight Magnetic Resonance Angiography Generation Model Based on Cycle-Consistent Generative Adversarial Network Using PETRA-MRA in the Patients With Treated Intracranial Aneurysm

被引:6
作者
You, Sung-Hye [1 ]
Cho, Yongwon [2 ]
Kim, Byungjun [1 ]
Yang, Kyung-Sook [3 ]
Kim, Bo Kyu [1 ]
Park, Sang Eun [1 ]
机构
[1] Korea Univ, Dept Radiol, Anam Hosp, Coll Med, Seoul, South Korea
[2] Korea Univ, Coll Med, Biomed Res Ctr, Seoul, South Korea
[3] Korea Univ, Dept Biostat, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
deep learning; magnetic resonance angiography; ultra-short echo time; intracranial aneurysm; artifact; ASSISTED COIL EMBOLIZATION; RADIAL ACQUISITION; SILENT SCAN; FOLLOW-UP; REDUCTION; IMAGES; STENT; FLOW;
D O I
10.1002/jmri.28114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pointwise encoding time reduction with radial acquisition (PETRA) magnetic resonance angiography (MRA) is useful for evaluating intracranial aneurysm recurrence, but the problem of severe background noise and low peripheral signal-to-noise ratio (SNR) remain. Deep learning could reduce noise using high- and low-quality images. Purpose To develop a cycle-consistent generative adversarial network (cycleGAN)-based deep learning model to generate synthetic TOF (synTOF) using PETRA. Study type Retrospective. Population A total of 377 patients (mean age: 60 +/- 11; 293 females) with treated intracranial aneurysms who underwent both PETRA and TOF from October 2017 to January 2021. Data were randomly divided into training (49.9%, 188/377) and validation (50.1%, 189/377) groups. Field Strength/Sequence Ultra-short echo time and TOF-MRA on a 3-T MR system. Assessment For the cycleGAN model, the peak SNR (PSNR) and structural similarity (SSIM) were evaluated. Image quality was compared qualitatively (5-point Likert scale) and quantitatively (SNR). A multireader diagnostic optimality evaluation was performed with 17 radiologists (experience of 1-18 years). Statistical Tests Generalized estimating equation analysis, Friedman's test, McNemar test, and Spearman's rank correlation. P < 0.05 indicated statistical significance. Results The PSNR and SSIM between synTOF and TOF were 17.51 [16.76; 18.31] dB and 0.71 +/- 0.02. The median values of overall image quality, noise, sharpness, and vascular conspicuity were significantly higher for synTOF than for PETRA (4.00 [4.00; 5.00] vs. 4.00 [3.00; 4.00]; 5.00 [4.00; 5.00] vs. 3.00 [2.00; 4.00]; 4.00 [4.00; 4.00] vs. 4.00 [3.00; 4.00]; 3.00 [3.00; 4.00] vs. 3.00 [2.00; 3.00]). The SNRs of the middle cerebral arteries were the highest for synTOF (synTOF vs. TOF vs. PETRA; 63.67 [43.25; 105.00] vs. 52.42 [32.88; 74.67] vs. 21.05 [12.34; 37.88]). In the multireader evaluation, there was no significant difference in diagnostic optimality or preference between synTOF and TOF (19.00 [18.00; 19.00] vs. 20.00 [18.00; 20.00], P = 0.510; 8.00 [6.00; 11.00] vs. 11.00 [9.00, 14.00], P = 1.000). Data Conclusion The cycleGAN-based deep learning model provided synTOF free from background artifact. The synTOF could be a versatile alternative to TOF in patients who have undergone PETRA for evaluating treated aneurysms. Evidence Level 4 Technical Efficacy Stage 1
引用
收藏
页码:1513 / 1528
页数:16
相关论文
共 34 条
  • [1] Quiet T1-Weighted Pointwise Encoding Time Reduction with Radial Acquisition for Assessing Myelination in the Pediatric Brain
    Aida, N.
    Niwa, T.
    Fujii, Y.
    Nozawa, K.
    Enokizono, M.
    Murata, K.
    Obata, T.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (08) : 1528 - 1534
  • [2] Generation of Structural MR Images from Amyloid PET: Application to MR-Less Quantification
    Choi, Hongyoon
    Lee, Dong Soo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (07) : 1111 - 1117
  • [3] Image Synthesis in Multi-Contrast MRI With Conditional Generative Adversarial Networks
    Dar, Salman U. H.
    Yurt, Mahmut
    Karacan, Levent
    Erdem, Aykut
    Erdem, Erkut
    Cukur, Tolga
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (10) : 2375 - 2388
  • [4] Quiet Submillimeter MR Imaging of the Lung Is Feasible with a PETRA Sequence at 1.5 T
    Dournes, Gael
    Grodzki, David
    Macey, Julie
    Girodet, Pierre-Olivier
    Fayon, Michael
    Chateil, Jean-Francois
    Montaudon, Michel
    Berger, Patrick
    Laurent, Francois
    [J]. RADIOLOGY, 2015, 276 (01) : 258 - 265
  • [5] Deep-learning-based image quality enhancement of compressed sensing magnetic resonance imaging of vessel wall: comparison of self-supervised and unsupervised approaches
    Eun, Da-In
    Jang, Ryoungwoo
    Ha, Woo Seok
    Lee, Hyunna
    Jung, Seung Chai
    Kim, Namkug
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] Deep-Learning Generated Synthetic Double Inversion Recovery Images Improve Multiple Sclerosis Lesion Detection
    Finck, Tom
    Li, Hongwei
    Grundl, Lioba
    Eichinger, Paul
    Bussas, Matthias
    Muehlau, Mark
    Menze, Bjoern
    Wiestler, Benedikt
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (05) : 318 - 323
  • [7] Filling the dead-time gap in zero echo time MRI: Principles compared
    Froidevaux, Romain
    Weiger, Markus
    Brunner, David O.
    Dietrich, Benjamin E.
    Wilm, Bertram J.
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2036 - 2045
  • [8] Clinical evaluation of subtracted pointwise encoding time reduction with radial acquisition-based magnetic resonance angiography compared to 3D time-of-flight magnetic resonance angiography for improved flow dephasing at 3 Tesla
    Fu, Qing
    Zhang, Xiao-yong
    Deng, Xian-bo
    Liu, Ding-xi
    [J]. MAGNETIC RESONANCE IMAGING, 2020, 73 : 104 - 110
  • [9] Goodfellow IJ, 2014, ADV NEUR IN, V27, P2672
  • [10] Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)
    Grodzki, David M.
    Jakob, Peter M.
    Heismann, Bjoern
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 510 - 518