Seismic Performance of Story-Added Type Buildings Remodeled with Story Seismic Isolation Systems

被引:7
作者
Hur, Moo-Won [1 ]
Park, Tae-Won [1 ]
机构
[1] Dankook Univ, Dept Architectural Engn, Yongin 16890, South Korea
关键词
remodeling; vertically story-added; isolation system; isolation period; maximum response acceleration; maximum response displacement;
D O I
10.3390/buildings12030270
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Story-added type apartments have recently been introduced as an option to resolve the housing supply shortage in areas that are undergoing rapid industrialization and urbanization. However, the infrastructure of old apartment buildings (>20 years old) makes it difficult to introduce convenient facilities and recent technologies such as those involving the Internet of Things and augmented realities. Applying housing technologies to existing older apartments can increase housing supply and potentially address the aforementioned issues. However, story-added building remodeling increases the weight of existing buildings, necessitating seismic reinforcement, which is the major obstacle when performing vertical building extensions. This study presents methods for lowering seismic loads associated with vertical augmentation of buildings while improving the seismic performance. A model of a vertically extended building with three additional stories constructed on top of an existing 15-story apartment building was used. The applied seismic isolation system decreased the maximum response acceleration on top of the remodeled building by approximately 70% and 65% in the X-direction and Y-direction, respectively, while decreasing the base shear plane by approximately 30% in both the X- and Y-directions in comparison with forces on a non-seismically isolated building. These results demonstrate that the use of a seismic isolation system can significantly reduce seismic loads.
引用
收藏
页数:19
相关论文
共 19 条
  • [1] ACI 318, 2019, 318R19 ACI
  • [2] [Anonymous], 2016, ASCE 7-16
  • [3] Antonello D.L., 2020, SOIL DYN EARTHQ ENG, V130, P1
  • [4] Choi Jaepil, 2018, [Journal of the Architectural Institute of Korea Planning & Design, 대한건축학회논문집 계획계], V34, P3
  • [5] Effects of Isolation Period Difference and Beam-Column Stiffness Ratio on the Dynamic Response of Reinforced Concrete Buildings
    Chun, Young-Soo
    Hur, Moo-Won
    [J]. INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2015, 9 (04) : 439 - 451
  • [6] Experimental realisation of the real-time controlled smart magnetorheological elastomer seismic isolation system with shake table
    Gu, Xiaoyu
    Li, Jianchun
    Li, Yancheng
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (01)
  • [7] Hur M.W., 2017, J KOREA CONCR I, V29, P323
  • [8] Hur M.W., 2017, J KOREA CONCR I, V29, P705
  • [9] 천영수, 2010, [Journal of The Korea Institute for Structural Maintenance and Inspection, 한국구조물진단유지관리공학회 논문집], V14, P93
  • [10] Hwang K.T, 2018, MAG KOREA CONCR I, V30, P44