Amplitude Integrated Electroencephalogram as a Prognostic Tool in Neonates with Hypoxic-Ischemic Encephalopathy: A Systematic Review

被引:78
作者
del Rio, Ruth [1 ]
Ochoa, Carlos [2 ]
Alarcon, Ana [1 ,3 ]
Arnaez, Juan [4 ]
Blanco, Dorotea [5 ]
Garcia-Alix, Alfredo [1 ]
机构
[1] Hosp St Joan de Deu, Inst Recerca Pediat, Dept Neonatol, Barcelona, Spain
[2] Hosp Virgen de la Concha, Res Unit, Zamora, Spain
[3] Oxford Univ Hosp NHS Fdn Trust, Dept Neonatol, Oxford, England
[4] Hosp Univ Burgos, Dept Neonatol, Burgos, Spain
[5] Hosp Univ Gregorio Maranon, Dept Neonatol, Madrid, Spain
关键词
FULL-TERM INFANTS; NEAR-INFRARED SPECTROSCOPY; PREDICTIVE-VALUE; NEUROLOGIC EXAMINATION; HYPOTHERMIA TREATMENT; ASPHYXIATED INFANTS; PERINATAL ASPHYXIA; EEG; ACCURACY; BIRTH;
D O I
10.1371/journal.pone.0165744
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction Perinatal management and prognostic value of clinical evaluation and diagnostic tools have changed with the generalization of therapeutic hypothermia (TH) in infants with hypoxic- ischemic encephalopathy (HIE) Aim to ascertain the prognostic value of amplitude integrated electroencephalogram (aEEG) in neonates with HIE considering hours of life and treatment with TH. Methods A systematic review was performed. Inclusion criteria were studies including data of neonates with HIE, treated or not with TH, monitored with aEEG and with neurodevelopmental follow-up of at least 12 months. The period of bibliographic search was until February 2016. No language restrictions were initially applied. Consulted databases were MEDLINE, Scopus, CINHAL and the Spanish language databases GuiaSalud and Bravo. Article selection was performed by two independent reviewers. Quality for each individual paper selected was evaluated using QUADAS-2. Review Manager (RevMan) version 5.3 software was used. Forest plots were constructed to graphically show sensitivity and specificity for all included studies, separating patients treated or not with hypothermia. Summary statistics were estimated using bivariate models and random effects approaches with the R package MADA from summary ROC curves. Meta-regression was used to estimate heterogeneity and trends. Results from the 403 articles initially identified, 17 were finally included and critically reviewed. In infants not treated with hypothermia the maximum reliability of an abnormal aEEG background to predict death or moderate/severe disability was at 36 hours of life, when a positive post-test probability of 97.90% was achieved (95% CI 88.40 to 99.40%). Positive likelihood ratio (+LR) at these hours of life was 26.60 (95% CI 4.40 to 94.90) and negative likelihood ratio (-LR) was 0.23 (95% CI 0.10 to 0.44). A high predictive value was already present at 6 hours of life in this group of patients, with a positive post-test probability of 88.20% (95% CI 79.80 to 93%) and a +LR of 4.34 (95% CI 2.31 to 7.73). In patients treated with TH the maximum predictive reliability was achieved at 72 hours of life (post-test probability of 95.70%, 95% CI 84.40 to 98.50%). +LR at this age was 24.30 (95% CI 5.89 to 71.30) and -LR was 0.40 (95% CI 0.25 to 0.57). Predictive value of aEEG at 6 hours of life was low in these patients (59.10%, 95% CI 55.70 to 63%). Conclusion This study confirms that aEEG's background activity, as recorded during the first 72 hours after birth, has a strong predictive value in infants with HIE treated or not with TH. Predictive values of traces throughout the following 72 hours are a helpful guide when considering and counselling parents about the foreseeable long-term neurological outcome
引用
收藏
页数:17
相关论文
共 42 条
[1]   Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography [J].
al Naqeeb, N ;
Edwards, AD ;
Cowan, FM ;
Azzopardi, D .
PEDIATRICS, 1999, 103 (06) :1263-1271
[2]   Early predictors of short term neurodevelopmental outcome in asphyxiated cooled infants. A combined brain amplitude integrated electroencephalography and near infrared spectroscopy study [J].
Ancora, Gina ;
Maranella, Eugenia ;
Grandi, Sara ;
Sbravati, Francesca ;
Coccolini, Elena ;
Savini, Silvia ;
Faldella, Giacomo .
BRAIN & DEVELOPMENT, 2013, 35 (01) :26-31
[3]   A combined a-EEG and MR spectroscopy study in term newborns with hypoxic-ischemic encephalopathy [J].
Ancora, Gina ;
Soffritti, Silvia ;
Lodi, Raffaele ;
Tonon, Caterina ;
Grandi, Sara ;
Locatelli, Chiara ;
Nardi, Laura ;
Bisacchi, Nicoletta ;
Testa, Claudia ;
Tani, Giovanni ;
Ambrosetto, Paolo ;
Faldella, Giacomo .
BRAIN & DEVELOPMENT, 2010, 32 (10) :835-842
[4]  
[Anonymous], 2015, GRUP TRAB GUIA PRACT
[5]  
[Anonymous], 2012, PAEDIAT CHILD HLTH, V17, P41
[6]   Predictive value of the amplitude integrated EEG in infants with hypoxic ischaemic encephalopathy: data from a randomised trial of therapeutic hypothermia [J].
Azzopardi, Denis .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2014, 99 (01) :F80-F82
[7]  
Blanco D, 2011, AN PEDIAT BARC, V75, P341, DOI DOI 10.1016/J.ANPEDI.2011.07.012
[8]  
Chalak L, NEONATAL GUIDELINE H
[9]   Accuracy of amplitude-integrated electroencephalography in the prediction of neurodevelopmental outcome in asphyxiated infants receiving hypothermia treatment [J].
Cseko, A. J. ;
Bango, M. ;
Lakatos, P. ;
Kardasi, J. ;
Pusztai, L. ;
Szabo, M. .
ACTA PAEDIATRICA, 2013, 102 (07) :707-711
[10]   PREDICTIVE VALUE OF EARLY NEUROIMAGING, PULSED DOPPLER AND NEUROPHYSIOLOGY IN FULL-TERM INFANTS WITH HYPOXIC-ISCHEMIC ENCEPHALOPATHY [J].
EKEN, P ;
TOET, MC ;
GROENENDAAL, F ;
DEVRIES, LS .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1995, 73 (02) :F75-F80