Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis

被引:50
作者
Hamon, Michele [1 ]
Champ-Rigot, Laure [3 ]
Morello, Remy [2 ]
Riddell, John W. [3 ]
Hamon, Martial
机构
[1] Ctr Hosp Univ Caen, Serv Maladies Coeur Vaisseaux, Ave Cote Nacre, F-14033 Caen, Normandy, France
[2] Univ Hosp, Dept Stat, F-14033 Caen, Normandy, France
[3] Univ Hosp, Dept Cardiol, F-14033 Caen, Normandy, France
关键词
MSCT; computed tomography; restenosis; stent; invasive angiography; coronary angiography; meta-analysis;
D O I
10.1007/s00330-007-0743-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was designed to define the current role of multislice spiral computed tomography (MSCT) for the diagnosis of coronary in-stent restenosis using a meta-analytic process. Restenosis remains a limitation after coronary stent implantation and contributes to a substantial number of coronary re-assessments by conventional invasive coronary angiography (CA). We identified 15 studies (807 patients) evaluating in-stent restenosis by means of both MSCT (>= 16 slices) and conventional CA until February 2007. After data extraction the analysis was performed according to a random-effects model. The analysis pooled the results from 15 studies with a total of 1,175 stents. A substantial number of unassessable stents (13%) were excluded from the analysis underscoring the shortcomings of MSCT. With this major limitation the diagnostic performance of MSCT for in-stent restenosis detection can be summarized as follows: the sensitivity and specificity were 84% [95% confidence interval (CI) 77-89%] and 91% (95% CI 89-93%), respectively, with positive and negative likelihood ratios of 12.2 (95% CI 6.6-22.6) and 0.23 (95% CI 0.17-0.31), respectively, and with a diagnostic odds ratio of 67.9 (95% CI 34.4-134.1). MSCT has shortcomings difficult to overcome in daily practice for in-stent restenosis detection and continues to have moderately high sensitivity and specificity. The diagnostic role of this emerging technology as an alternative to CA for in-stent restenosis detection remains limited.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 34 条
[1]   Computed tomography coronary angiography [J].
Achenbach, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :1919-1928
[2]   Clinical effectiveness of bare-metal stenting compared with balloon angioplasty in total coronary occlusions: Insights from a systematic overview of randomized trials in light of the drug-eluting stent era [J].
Agostoni, P ;
Valgimigli, M ;
Biondi-Zoccai, GGL ;
Abbate, A ;
Garcia, HMG ;
Anselmi, M ;
Turri, M ;
McFadden, EP ;
Vassanelli, C ;
Serruys, PW ;
Colombo, A .
AMERICAN HEART JOURNAL, 2006, 151 (03) :682-689
[3]  
BUDOFF MJ, 2006, J AM COLL CARDIOL, V114, P1761
[4]  
Cademartiri F, 2005, RADIOL MED, V109, P500
[5]   Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT) [J].
Chabbert, V. ;
Carrie, D. ;
Bennaceur, M. ;
Maupas, E. ;
Lauwers, V. ;
Mhem, M. ;
Lhermusier, T. ;
Elbaz, M. ;
Joffre, F. ;
Rousseau, H. ;
Puel, J. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1452-1463
[6]   Conducting systematic reviews of diagnostic studies: Didactic guidelines [J].
Devillé W.L. ;
Buntinx F. ;
Bouter L.M. ;
Montori V.M. ;
De Vet H.C.W. ;
Van Der Windt D.A.W.M. ;
Bezemer P.D. .
BMC Medical Research Methodology, 2 (1) :1-13
[7]   Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography - Comparison with invasive coronary angiography [J].
Ehara, Mariko ;
Kawai, Masato ;
Surmely, Jean-Francois ;
Matsubara, Tetsuo ;
Terashima, Mitsuyasu ;
Tsuchikane, Etsuo ;
Kinoshita, Yoshihisa ;
Ito, Tatsuya ;
Takeda, Yoshihiro ;
Nasu, Kenya ;
Tanaka, Nobuyoshi ;
Murata, Akira ;
Fujita, Hiroshi ;
Sato, Koyo ;
Kodama, Atsuko ;
Katoh, Osamu ;
Suzuki, Takahiko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) :951-959
[8]   Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography [J].
Gaspar, T ;
Halon, DA ;
Lewis, BS ;
Adawi, S ;
Schliamser, JE ;
Rubinshtein, R ;
Flugelman, MY ;
Peled, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) :1573-1579
[9]   Assessment of coronary artery stents by 16 slice computed tomography [J].
Gilard, M ;
Cornily, JC ;
Pennec, PY ;
Le Gal, G ;
Nonent, M ;
Mansourati, J ;
Blanc, JJ ;
Boschat, J .
HEART, 2006, 92 (01) :58-61
[10]   Noninvasive assessment of left main coronary stent patency with 16-slice computed tomography [J].
Gilard, M ;
Cornily, JC ;
Rioufol, G ;
Finet, G ;
Pennec, PY ;
Mansourati, J ;
Blanc, JJ ;
Boschat, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (01) :110-112