Photoplethysmography sampling frequency: pilot assessment of how low can we go to analyze pulse rate variability with reliability?

被引:89
作者
Choi, A. [1 ]
Shin, H. [2 ]
机构
[1] Gachon Univ, Dept Software, Seongnam, South Korea
[2] Chonnam Natl Univ, Dept Biomed Engn, Yeosu, South Korea
基金
新加坡国家研究基金会;
关键词
heart rate variability; photoplethysmography; pulse rate variability; sampling frequency; HEART-RATE-VARIABILITY; SMARTPHONE;
D O I
10.1088/1361-6579/aa5efa
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pulse rate variability (PRV) analysis appears as the first alternative to heart rate variability analysis for wearable devices; however, there is a constraint on computational load and energy consumption for the limited system resources available to the devices. Considering that adjustment of the sampling frequency is one of the strategies for reducing computational load and power consumption, this study aimed to investigate the influence of sampling frequency (f(s)) on PRV analysis and to find the minimum sampling frequency while maintaining reliability. We generated 5000, 2500, 1000, 500, 250, 100, 50, 25, 20, 15, 10, 5 Hz down-sampled photoplethysmograms from 10 kHz-sampled PPGs and derived time-and frequency-domain variables of the PRV. These included AVNN, SDNN, SDSD, RMSSD, NN50, pNN50, total power, VLF, LF, HF, LF/HF, nLF and nHF for each down-sampled signal. Derived variables were compared with heart rate variability of the 10 kHz-sampled electrocardiograms, and then statistically investigated using one-way ANOVA test and Bland-Altman analysis. As a result, significant differences (P < 0.05) were found for SDNN, SDSD, RMSSD, NN50, pNN50, TP, HF, LF/HF, nLF and nHF, but not for AVNN, VLF and LF. Based on the post hoc tests, it was found that the NN50 and pNN50, SDSD and RMSSD, LF/HF and nHF, SDNN, TP and nLF analysis had significant differences at f(s) <= 20 Hz, f(s) <= 15 Hz, f(s) <= 10 Hz; f(s) = 5 Hz, respectively. In other words, a significant difference was not seen for any variable if the f(s) was greater than 25 Hz. Consequently, our pilot study suggests that analysis of variability in the time and frequency domain from pulse rate obtained through PPG may be potentially as reliable as that derived from the analysis of the electrocardiogram, provided that f(s) >= 25 Hz sampling frequency is used.
引用
收藏
页码:586 / 600
页数:15
相关论文
共 24 条
  • [1] [Anonymous], 2010, DISCRETE TIME SIGNAL
  • [2] Brown M.B., 1974, Journal of the American Statistical Association, V69, P364
  • [3] Camm AJ, 1996, CIRCULATION, V93, P1043
  • [4] Camm AJ, 1996, EUR HEART J, V17, P354
  • [5] Comparison of the heart rate variability parameters obtained from the electrocardiogram and the blood pressure wave
    Carrasco, S
    Gonzalez, R
    Jimenez, J
    Roman, R
    Medina, V
    Azpiroz, J
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1998, 22 (05) : 195 - 205
  • [6] Interchangeability between heart rate and photoplethysmography variabilities during sympathetic stimulations
    Charlot, K.
    Cornolo, J.
    Brugniaux, J. V.
    Richalet, J. P.
    Pichon, A.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (12) : 1357 - 1369
  • [7] Smartphone-Derived Heart-Rate Variability and Training Load in a Women's Soccer Team
    Flatt, Andrew A.
    Esco, Michael R.
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2015, 10 (08) : 994 - 1000
  • [8] Estimating Respiratory and Heart Rates from the Correntropy Spectral Density of the Photoplethysmogram
    Garde, Ainara
    Karlen, Walter
    Ansermino, J. Mark
    Dumont, Guy A.
    [J]. PLOS ONE, 2014, 9 (01):
  • [9] Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
    Gil, E.
    Orini, M.
    Bailon, R.
    Vergara, J. M.
    Mainardi, L.
    Laguna, P.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) : 1271 - 1290
  • [10] Development and Validation of a Smartphone Heart Rate Acquisition Application for Health Promotion and Wellness Telehealth Applications
    Gregoski, Mathew J.
    Mueller, Martina
    Vertegel, Alexey
    Shaporev, Aleksey
    Jackson, Brenda B.
    Frenzel, Ronja M.
    Sprehn, Sara M.
    Treiber, Frank A.
    [J]. INTERNATIONAL JOURNAL OF TELEMEDICINE AND APPLICATIONS, 2012, 2012