Optimization of image quality and patient dose in radiographs of paediatric extremities using direct digital radiography

被引:15
|
作者
Jones, A. [1 ,2 ]
Ansell, C. [3 ]
Jerrom, C. [1 ]
Honey, I. D. [1 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Dept Med Phys, London, England
[2] Western Sydney Local Hlth Dist, Dept Med Phys, Sydney, NSW, Australia
[3] Evelina London Childrens Hosp, Guys & St Thomas NHS Fdn Trust, Dept Radiol, London, England
关键词
COMPUTED RADIOGRAPHY; SCREEN-FILM; FLAT-PANEL; REDUCTION; FILTRATION; FRACTURES; DETECTOR; NOISE; CHEST;
D O I
10.1259/bjr.20140660
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to evaluate the effect of beamquality on the image quality (IQ) of ankle radiographs of paediatric patients in the age range of 0-1 year whilst maintaining constant effective dose (ED). Methods: Lateral ankle radiographs of an infant foot phantom were taken at a range of tube potentials (40.0-64.5 kV(p)) with and without 0.1-mm copper (Cu) filtration using a Trixell Pixium 4600 detector (Trixell, Morains, France). ED to the patient was computed for the default exposure parameters using PCXMC v. 2.0 and was fixed for other beam qualities by modulating the tube current-time product. The contrast-to-noise ratio (CNR) was measured between the tibia and adjacent soft tissue. The IQ of the phantom images was assessed by three radiologists and a reporting radiographer. Four IQ criteria were defined each with a scale of 1-3, giving a maximum score of 12. Finally, a service audit of clinical images at the default and optimum beam qualities was undertaken. Results: The measured CNR for the 40kVp/no Cu image was 12.0 compared with 7.6 for the default mode (55 0.1mm Cu). An improvement in the clinical IQ scores was also apparent at this lower beam quality. Conclusion: Lowering tube potential and removing filtration improved the clinical IQ of paediatric ankle radiographs in this age range. Advances in knowledge: There are currently no UK guidelines on exposure protocols for paediatric imaging using direct digital radiography. A lower beam quality will produce better IQ with no additional dose penalty for infant extremity imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] PATIENT DOSE IN DIGITAL RADIOGRAPHY UTILISING BMI CLASSIFICATION
    Metaxas, Vasileios I.
    Messaris, Gerasimos A.
    Lekatou, Aristea N.
    Petsas, Theodore G.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 155 - 167
  • [22] Dose optimisation in paediatric radiography - Using regression models to investigate the relative impact of acquisition factors on image quality and radiation dose
    Ali, Ali Mohammed
    Hogg, Peter
    England, Andrew
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 61 - 68
  • [23] Effect of Aluminium Filtration on Dose and Image Quality in Paediatric Slot-scanning Radiography
    Perks, T. D.
    Trauernicht, C.
    Hartley, T.
    Hobson, C.
    Lawson, A.
    Scholtz, P.
    Dendere, R.
    Steiner, S.
    Douglas, T. S.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2332 - 2335
  • [24] The effect of added filtration on radiation dose and image quality in digital radiography of newborns
    Papadakis, Antonios E.
    Giannakaki, Vasiliki
    Hatzidaki, Eleftheria
    Damilakis, John
    PEDIATRIC RADIOLOGY, 2023, 53 (10) : 2060 - 2068
  • [25] Effects of Projections on Radiation Dose for and Image Quality of Chest Digital Radiography for Children
    Xu, Hongrong
    Liu, Bo
    Cai, Jinhua
    Zheng, Huan
    Zheng, Helin
    Yang, Qiurui
    Yao, Changhong
    CURRENT MEDICAL IMAGING, 2021, 17 (12) : 1496 - 1502
  • [26] A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography
    Wouter J.H. Veldkamp
    Lucia J.M. Kroft
    Jan Pieter A. van Delft
    Jacob Geleijns
    Journal of Digital Imaging, 2009, 22 : 114 - 125
  • [27] Image Quality in Digital Industrial Radiography
    Ewert, Uwe
    Zscherpel, Uwe
    Heyne, Klara
    Jechow, Mirko
    Bavendiek, Klaus
    MATERIALS EVALUATION, 2012, 70 (08) : 955 - 964
  • [28] A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography
    Veldkamp, Wouter J. H.
    Kroft, Lucia J. M.
    van Delft, Jan Pieter A.
    Geleijns, Jacob
    JOURNAL OF DIGITAL IMAGING, 2009, 22 (02) : 114 - 125
  • [29] Radiation Dose Reduction in Digital Radiography Using Wavelet-Based Image Processing Methods
    Watanabe, Haruyuki
    Tsai, Du-Yih
    Lee, Yongbum
    Matsuyama, Eri
    Kojima, Katsuyuki
    MEDICAL IMAGING 2011: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2011, 7966
  • [30] EFFECTS OF RADIATION DOSE REDUCTION IN DIGITAL RADIOGRAPHY USING WAVELET-BASED IMAGE PROCESSING
    Watanabe, Haruyuki
    Tsai, Du-Yih
    Lee, Yongbum
    Matsuyama, Eri
    Kojima, Katsuyuki
    13TH IMEKO TC1-TC7 JOINT SYMPOSIUM - WITHOUT MEASUREMENT NO SCIENCE, WITHOUT SCIENCE NO MEASUREMENT, 2010, 238