Mechanical chest compressions with trapezoidal waveform improve haemodynamics during cardiac arrest

被引:15
作者
Kramer-Johansen, Jo [1 ,2 ,3 ]
Pytte, Morten [1 ,2 ,3 ]
Tomlinson, Ann-Elin [1 ]
Sunde, Kjetil [1 ,2 ,3 ]
Dorph, Elizabeth [1 ,2 ,3 ]
Svendsen, Jan Vegard H. [4 ]
Eriksen, Morten [1 ]
Stromme, Taevje A. [1 ]
Wik, Lars [1 ,5 ]
机构
[1] Oslo Univ Hosp, Expt Med Res Inst, N-0407 Oslo, Norway
[2] Oslo Univ Hosp, Dept Anaesthesiol, Oslo, Norway
[3] Oslo Univ Hosp, Div Prehosp Med, Oslo, Norway
[4] Laerdal Med, Stavanger, Norway
[5] Oslo Univ Hosp, Natl Competence Ctr Emergency Med, Oslo, Norway
关键词
Cardiopulmonary resuscitation; Mechanical chest compression; Swine; Haemodynamics; Cerebral blood flow; Coronary perfusion pressure; Compression waveform; CARBON-DIOXIDE CONCENTRATION; CORONARY BLOOD-FLOW; CARDIOPULMONARY-RESUSCITATION; ACTIVE DECOMPRESSION; ARTERIAL-PRESSURE; PORCINE MODEL; ACD-CPR; QUALITY; DEVICE; PIGS;
D O I
10.1016/j.resuscitation.2010.10.009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: During manual chest compressions for cardiac arrest the waveforms of chest compressions are generally sinusoidal, whereas mechanical chest compression devices can have different waveforms, including trapezoidal. We studied the haemodynamic differences of such waveforms in a porcine model of cardiac arrest. Methods: Eight domestic pigs (weight 31 3 kg) were anaesthetised and instrumented to continuously monitor aortic (AP) and right atrial pressure (RAP), carotid (CF) and cerebral cortical microcirculation blood flow (CCF). Coronary perfusion pressure (CPP) was calculated as the maximal difference between AP and RAP during diastole or decompression phase. After 4 min of electrically induced ventricular fibrillation, mechanical chest compressions were performed with four different waveforms in a factorial design, and in randomized sequence for 3 min each. Resulting differences are presented as mean with 95% confidence intervals. Results: Mean AP and RAP were higher with trapezoid than sinusoid chest compressions, difference 5.7 (0.7, 11) and 6.3 (2.1, 11) mmHg, respectively. Flow measured as CF and CCF was also improved with trapezoidal waveform, difference 14 (2.8, 26) ml/min and 11 (5.6, 17)% of baseline, respectively, with a parallel, non-significant (P=0.08) trend for CPP. Active vs. passive decompression to zero level improved CF, but without even a trend for CPP. Conclusion: Trapezoid chest compressions and active decompression to zero level improved blood flow to the brain. The compression waveform is an additional factor to consider when comparing mechanical and manual chest compressions and when comparing different compression devices. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 30 条
  • [1] Clinical consequences of the introduction of mechanical chest compression in the EMS system for treatment of out-of-hospital cardiac arrest -: A pilot study
    Axelsson, Christer
    Nestin, Johan
    Svensson, Leif
    Axelsson, Asa B.
    Herlitz, Johan
    [J]. RESUSCITATION, 2006, 71 (01) : 47 - 55
  • [2] Design of near-optimal waveforms for chest and abdominal compression and decompression in CPR using computer-simulated evolution
    Babbs, CF
    [J]. RESUSCITATION, 2006, 68 (02) : 277 - 293
  • [3] A randomized comparison of manual, mechanical and high-impulse chest compression in a porcine model of prolonged ventricular fibrillation
    Betz, AE
    Menegazzi, JJ
    Logue, ES
    Callaway, CW
    Wang, HE
    [J]. RESUSCITATION, 2006, 69 (03) : 495 - 501
  • [4] CARTER LP, 1991, CEREBROVAS BRAIN MET, V3, P246
  • [5] RELATIVE LACK OF CORONARY BLOOD-FLOW DURING CLOSED-CHEST RESUSCITATION IN DOGS
    DITCHEY, RV
    WINKLER, JV
    RHODES, CA
    [J]. CIRCULATION, 1982, 66 (02) : 297 - 302
  • [6] Active compression-decompression CPR necessitates follow-up post mortem
    Englund, E
    Kongstad, PC
    [J]. RESUSCITATION, 2006, 68 (01) : 161 - 162
  • [7] A COMPARISON OF MEASUREMENTS OF CEREBRAL BLOOD-FLOW IN THE RABBIT USING LASER DOPPLER SPECTROSCOPY AND RADIONUCLIDE LABELED MICROSPHERES
    EYRE, JA
    ESSEX, TJH
    FLECKNELL, PA
    BARTHOLOMEW, PH
    SINCLAIR, JI
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (01): : 65 - 74
  • [8] CARDIAC-OUTPUT DURING CARDIOPULMONARY RESUSCITATION AT VARIOUS COMPRESSION RATES AND DURATIONS
    FITZGERALD, KR
    BABBS, CF
    FRISSORA, HA
    DAVIS, RW
    SILVER, DI
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (03): : H442 - H448
  • [9] Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest - A randomized trial
    Hallstrom, Al
    Rea, Thomas D.
    Sayre, Michael R.
    Christenson, James
    Anton, Andy R.
    Mosesso, Vince N., Jr.
    Van Ottingham, Lois
    Olsufka, Michele
    Pennington, Sarah
    White, Lynn J.
    Yahn, Stephen
    Husar, James
    Morris, Mary F.
    Cobb, Leonard A.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (22): : 2620 - 2628
  • [10] Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest - Improved hemodynamics and mechanisms
    Halperin, HR
    Paradis, N
    Ornato, JP
    Zviman, M
    LaCorte, J
    Lardo, A
    Kern, KB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (11) : 2214 - 2220