Diathermy versus scalpel for skin incision in patients undergoing open inguinal hernia repair: A systematic review and meta-analysis

被引:5
作者
Hajibandeh, Shahab [1 ]
Hajibandeh, Shahin [2 ]
Maw, Andrew [1 ]
机构
[1] Glan Clwyd Gen Hosp, Dept Colorectal & Gen Surg, Rhyl, Wales
[2] Sandwell & West Birmingham Hosp NHS Trust, Dept Gen Surg, Birmingham, W Midlands, England
关键词
Scalpel; Diathermy; Inguinal hernia; MIDLINE LAPAROTOMY; ELECTROCAUTERY; INFECTION;
D O I
10.1016/j.ijsu.2020.01.020
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To compare outcomes of diathermy and scalpel for skin incision in patients undergoing open inguinal hernia repair. Methods: We performed a systematic review in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement standards. We conducted a search of electronic information sources to identify all randomised controlled trials (RCTs) and observational studies comparing use of diathermy and scalpel for skin incision in patients undergoing inguinal hernia repair. Surgical site infection (SSI) was the primary outcome measure. Secondary outcome measures included haematoma, seroma, visual analogue scale (VAS) pain score at 6 h, 12 h, and 24 h, and incision time. We used Cochrane risk of bias tool and ROBINS-I tool to assess the risk of bias of randomised and non-randomised studies. Fixed-effect model was applied to calculate pooled outcome data. Results: We identified 9 studies, 4 randomised controlled trials and 5 prospective cohort studies, enrolling a total of 830 patients. Meta-analysis of RCTs showed no difference between the diathermy and scalpel groups in terms of surgical site infection (OR: 0.77, 95% CI 0.34, 1.75, P = 0.53), seroma (OR: 0.86, 95% CI 0.29, 2.55, P = 0.78), VAS pain score at 6 h (MD: -0.10, 95% CI -0.31, 0.11, P = 0.34), 12 h (MD: -0.10, 95% CI -0.13, 0.33, P = 0.40), and 24 h (MD: 0.03, 95% CI -0.16, 0.21, P = 0.79). Use of diathermy for skin incision was associated with shorter incision time (MD: -36.00, 95% CI -47.92, -24.08, P < 0.00001) and lower risk of haematoma (OR: 0.14, 95% CI 0.03, 0.65, P = 0.01). Meta-analysis of observational studies showed no difference between the diathermy and scalpel groups in terms of surgical site infection (OR: 0.87, 95% CI 0.54, 1.39, P = 0.55), haematoma (OR 0.14, 95% CI 0.02-1.23, P = 0.08), seroma (OR: 0.86, 95% CI 0.29, 2.55, P = 0.78), VAS pain score at 6 h (MD: -0.10, 95% CI -0.44, 0.24, P = 0.56), 12 h (MD: -0.10, 95% CI -0.26, 0.46, P = 0.58), and 24 h (MD: 0.10, 95% CI -0.27, 0.47, P = 0.59). Use of diathermy for skin incision was associated with shorter incision time (MD: -39.40, 95% CI -41.02, -37.78, P < 0.00001). The results remained consistent through sensitivity analyses. The between-study heterogeneity was low and the quality of the available evidence was moderate. Conclusions: There is no difference between use of diathermy and scalpel for skin incision in patients undergoing open inguinal hernia repair in terms of surgical site infection, seroma and postoperative pain. Use of diathermy for skin incision may be associated with shorter incision time and may reduce the risk of haematoma formation.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [31] Cutting electrocautery versus scalpel for surgical incisions: a systematic review and meta-analysis
    Ismail, Ammar
    Abushouk, Abdelrahman Ibrahim
    Elmaraezy, Ahmed
    Menshawy, Amr
    Menshawy, Esraa
    Ismail, Mahmoud
    Samir, Esraa
    Khaled, Anas
    Zakarya, Hagar
    El-Tonoby, Abdelrahman
    Ghanem, Esraa
    JOURNAL OF SURGICAL RESEARCH, 2017, 220 : 147 - 163
  • [32] Laparoscopic Versus Open Preperitoneal Mesh Repair of Inguinal Hernia: an Integrated Systematic Review and Meta-analysis of Published Randomized Controlled Trials
    Muhammad Shafique Sajid
    Jennifer Caswell
    Krishna K. Singh
    Indian Journal of Surgery, 2015, 77 : 1258 - 1269
  • [33] A systematic review and meta-analysis of caudal blockade versus alternative analgesic strategies for pediatric inguinal hernia repair
    Baird, Robert
    Guilbault, Marie-Pier
    Tessier, Rachel
    Ansermino, J. Mark
    JOURNAL OF PEDIATRIC SURGERY, 2013, 48 (05) : 1077 - 1085
  • [34] Oblique Incision Versus Transverse Incision in Open Inguinal Hernia Repair - A Comparative Study
    Gupta, Shalabh
    Shah, Deep
    Solanki, Naveen Kumar
    Kumar, Aparajeeta
    Agrawal, Gopal Prasad
    Kumar, Yogendra
    INDIAN JOURNAL OF SURGERY, 2025,
  • [35] Evaluating the safety profile of anti-platelet therapy in patients undergoing elective inguinal hernia repair: a systematic review and meta-analysis
    Davey, Matthew G.
    Joyce, William P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 (02) : 897 - 902
  • [36] Optimal timing for inguinal hernia repair in premature infants: a systematic review and meta-analysis
    Masoudian, Pourya
    Sullivan, Katrina J.
    Mohamed, Hisham
    Nasr, Ahmed
    JOURNAL OF PEDIATRIC SURGERY, 2019, 54 (08) : 1539 - 1545
  • [37] Robotic inguinal hernia repair: is technology taking over? Systematic review and meta-analysis
    A. Aiolfi
    M. Cavalli
    G. Micheletto
    P. G. Bruni
    F. Lombardo
    C. Perali
    G. Bonitta
    D. Bona
    Hernia, 2019, 23 : 509 - 519
  • [38] Open darn repair vs open mesh repair of inguinal hernia: a systematic review and meta-analysis of randomised and non-randomised studies
    Finch, D. A.
    Misra, V. A.
    Hajibandeh, S.
    HERNIA, 2019, 23 (03) : 523 - 539
  • [39] Open darn repair vs open mesh repair of inguinal hernia: a systematic review and meta-analysis of randomised and non-randomised studies
    D. A. Finch
    V. A. Misra
    S. Hajibandeh
    Hernia, 2019, 23 : 523 - 539
  • [40] Evaluating the safety profile of anti-platelet therapy in patients undergoing elective inguinal hernia repair: a systematic review and meta-analysis
    Matthew G. Davey
    William P. Joyce
    Irish Journal of Medical Science (1971 -), 2024, 193 : 897 - 902