INSULATION FAULT DIAGNOSIS IN HIGH VOLTAGE POWER TRANSFORMERS BY MEANS OF LEAKAGE FLUX ANALYSIS

被引:16
作者
Cabanas, M. F. [1 ]
Pedrayes, F. [1 ]
Melero, M. G. [1 ]
Rojas, C. H. [1 ]
Orcajo, G. A. [1 ]
Cano, J. M. [1 ]
Norniella, J. G. [1 ]
机构
[1] Univ Oviedo, Dept Elect Engn, Gijon 33204, Spain
关键词
FINITE-ELEMENT-ANALYSIS; CURRENT TESTING PROBE; MAGNETIC-FIELD; INDUCTION-MOTOR; NOISE; SRM;
D O I
10.2528/PIER11010302
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power transformers in service are subjected to a wide variety of electrical, mechanical and thermal stresses capable of producing insulation faults. This type of failure figures amongst the most costly faults in distribution networks since it produces both machine outage and electrical supply interruption. Major research effort has therefore focused on the early detection of faults in the insulating systems of large high voltage power transformers. Although several industrial methods exist for the on-line and off-line monitoring of power transformers, all of them are expensive and complex, and require the use of specific electronic instrumentation. For these reasons, this paper will present the On-Line analysis of transformer leakage flux as an efficient alternative for assessing machine integrity and detecting the presence of insulating failures during their earliest stages. An industrial 400 kVA-20 kV/400 V transformer will be used for the experimental study. Very cheap, simple sensors, based on air core coils, will be used to measure the leakage flux of the transformer, and non-destructive tests will also be applied to the machine in order to analyse pre- and post-failure voltages induced in the coils.
引用
收藏
页码:211 / 234
页数:24
相关论文
共 48 条
[11]  
DELEON F, 1992, T POWER DELIVERY, V7
[12]   Giant magnetoresistance-based eddy-current sensor [J].
Dogaru, T ;
Smith, ST .
IEEE TRANSACTIONS ON MAGNETICS, 2001, 37 (05) :3831-3838
[13]  
DORMONT MJ, CALCULO CONSTRUCCION
[14]   LEAKAGE FIELD CHANGES OF AN INDUCTION MOTOR AS INDICATION OF NONSYMMETRIC SUPPLY [J].
ERLICKI, MS ;
PORAT, Y ;
ALEXANDR.A .
IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1971, IGA7 (06) :713-&
[15]   REDUCTION OF LEAKAGE MAGNETIC FIELD IN ELECTROMAGNETIC SYSTEMS BASED ON ACTIVE SHIELDING CONCEPT VERIFIED BY EIGEN VALUE ANALYSIS [J].
Faghihi, F. ;
Heydari, H. .
PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2009, 96 :217-236
[16]   Time stepping finite element analysis of broken bars fault in a three-phase squirrel-cage induction motor [J].
Faiz, J. ;
Ebrahimi, B. M. ;
Sharifian, M. B. B. .
PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2007, 68 :53-70
[17]   Mixed fault diagnosis in three-phase squirrel-cage induction motor using analysis of air-gap magnetic field [J].
Faiz, J. ;
Ebrahimi, B. M. .
PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2006, 64 :239-255
[18]  
Fang C. H., 2008, Progress In Electromagnetics Research B, V2, P103
[19]  
GHANDEHARI MB, 2008, PROGR ELECTROMAGNETI, V1, P45
[20]  
IEC, 1978, IEC PUBL, V599