MR-based semi-automated quantification of renal functional parameters with a two-compartment model - An interobserver analysis

被引:21
|
作者
Attenberger, U. I. [1 ]
Sourbrona, S. P. [1 ]
Notohamiprodjo, M. [1 ]
Lodemann, K. P. [3 ]
Glaser, C. G. [1 ]
Reiser, M. F. [1 ]
Schoenberg, S. O. [1 ,2 ]
Michaely, H. J. [1 ,2 ]
机构
[1] Univ Munich, Univ Hosp Grosshadern, Inst Clin Radiol, D-81377 Munich, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Inst Clin Radiol, D-68167 Mannheim, Germany
[3] Bracco Altana Pharma, D-78647 Constance, Germany
关键词
functional renal imaging; magnetic resonance; renal perfusion; interobserver agreement; 3; T;
D O I
10.1016/j.ejrad.2007.10.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the interobserver agreement in a semi-automated quantification approach of MR-renal perfusion and filtration parameters with a two-compartment model analysis. Materials and methods: Twelve consecutive patients underwent renal perfusion measurements after intravenous injection of 7 ml Gd-BOPTA at 4 ml/s at 3.0 T. Two independent observers placed two regions of interest (ROI) manually on the axial slice, one in the abdominal aorta to determine the arterial input function (AIF), and one at the tissue-air interface for retrospective triggering. The data were fitted on a pixel-by-pixel basis to the two-compartment model, producing maps of the per-fusion parameters F-p (plasma flow), T-p (plasma mean transit time) and of the tubular filtration parameters F-T (tubular flow) and T-T (tubular mean transit time). A cortical ROI was segmented by selecting those pixels with plasma volume V-p > 10 ml/100 ml, and the model fit was repeated on a ROI basis to produce the cortical averages. Results: The average values (observer 1/observer 2) were F-p (226.2/187.3 ml/100 ml/min), T-p (9.0/9.1 s), F-T (23.5/20.8 ml/100 mi/min), T-T (142.1/140.0 s). The correlation coefficients between both observers were 0.90 (Fp), 0.80 (T-p), 0.80 (F-T), 0.78 (T-T). Correlations of all values were significant (p < 0.05). A paired t-test yielded significant differences for Fp (P = 0.004). Discussion/conclusion: The data demonstrate a significant systematic difference for the parameter F-p, while T-p seems to be most stable. Further decrease of the residual variability of all parameters seems desirable to improve the robustness of the method for clinical routine. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 23 条
  • [21] Non-invasive quantification of hepatic blood flow by two-compartment model analysis with three components on Tc-99m-DTPA-galactosyl-HSA scintigraphy in children.
    Katch, C
    Tsukamoto, E
    Nakada, K
    Kanegae, K
    Shiga, T
    Mochizuki, T
    Itoh, K
    Tamaki, N
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1081 - 1081
  • [22] Validation of an active shape model-based semi-automated segmentation algorithm for the analysis of thigh muscle and adipose tissue cross-sectional areas
    Jana Kemnitz
    Felix Eckstein
    Adam G. Culvenor
    Anja Ruhdorfer
    Torben Dannhauer
    Susanne Ring-Dimitriou
    Alexandra M. Sänger
    Wolfgang Wirth
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 489 - 503
  • [23] Validation of an active shape model-based semi-automated segmentation algorithm for the analysis of thigh muscle and adipose tissue cross-sectional areas
    Kemnitz, Jana
    Eckstein, Felix
    Culvenor, Adam G.
    Ruhdorfer, Anja
    Dannhauer, Torben
    Ring-Dimitriou, Susanne
    Saenger, Alexandra M.
    Wirth, Wolfgang
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (05) : 489 - 503