MR-based semi-automated quantification of renal functional parameters with a two-compartment model - An interobserver analysis

被引:21
|
作者
Attenberger, U. I. [1 ]
Sourbrona, S. P. [1 ]
Notohamiprodjo, M. [1 ]
Lodemann, K. P. [3 ]
Glaser, C. G. [1 ]
Reiser, M. F. [1 ]
Schoenberg, S. O. [1 ,2 ]
Michaely, H. J. [1 ,2 ]
机构
[1] Univ Munich, Univ Hosp Grosshadern, Inst Clin Radiol, D-81377 Munich, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Inst Clin Radiol, D-68167 Mannheim, Germany
[3] Bracco Altana Pharma, D-78647 Constance, Germany
关键词
functional renal imaging; magnetic resonance; renal perfusion; interobserver agreement; 3; T;
D O I
10.1016/j.ejrad.2007.10.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the interobserver agreement in a semi-automated quantification approach of MR-renal perfusion and filtration parameters with a two-compartment model analysis. Materials and methods: Twelve consecutive patients underwent renal perfusion measurements after intravenous injection of 7 ml Gd-BOPTA at 4 ml/s at 3.0 T. Two independent observers placed two regions of interest (ROI) manually on the axial slice, one in the abdominal aorta to determine the arterial input function (AIF), and one at the tissue-air interface for retrospective triggering. The data were fitted on a pixel-by-pixel basis to the two-compartment model, producing maps of the per-fusion parameters F-p (plasma flow), T-p (plasma mean transit time) and of the tubular filtration parameters F-T (tubular flow) and T-T (tubular mean transit time). A cortical ROI was segmented by selecting those pixels with plasma volume V-p > 10 ml/100 ml, and the model fit was repeated on a ROI basis to produce the cortical averages. Results: The average values (observer 1/observer 2) were F-p (226.2/187.3 ml/100 ml/min), T-p (9.0/9.1 s), F-T (23.5/20.8 ml/100 mi/min), T-T (142.1/140.0 s). The correlation coefficients between both observers were 0.90 (Fp), 0.80 (T-p), 0.80 (F-T), 0.78 (T-T). Correlations of all values were significant (p < 0.05). A paired t-test yielded significant differences for Fp (P = 0.004). Discussion/conclusion: The data demonstrate a significant systematic difference for the parameter F-p, while T-p seems to be most stable. Further decrease of the residual variability of all parameters seems desirable to improve the robustness of the method for clinical routine. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 23 条
  • [1] Sensitivity Analysis of Two-Compartment Model Parameters for Extracorporeal Liver Therapy Purposes
    Jung, Aleksandra
    RECENT DEVELOPMENTS AND ACHIEVEMENTS IN BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2018, 647 : 257 - 263
  • [2] A methodology study for sodium quantification in bone and soft tissue based on in vivo neutron activation analysis using a two-compartment model
    Yue, Song
    Coyne, Mychaela
    Weaver, Connie M.
    Anderson, Cheryl A. M.
    Nie, Linda H.
    APPLIED RADIATION AND ISOTOPES, 2025, 218
  • [3] A Semi-Automated Knime-Based Workflow for High Throughput Quantification and Analysis of Centrosome Aberrations
    Dittrich, Tobias
    Bausch, Elena
    Bausch, Johannes
    Goldschmidt, Hartmut
    Hegenbart, Ute
    Schonland, Stefan O.
    Raab, Marc S.
    Kramer, Alwin
    BLOOD, 2019, 134
  • [4] Analysis of Parameters' Effects in Semi-Automated Knee Cartilage Segmentation Model: Data from the Osteoarthritis Initiative
    Gan, Hong-Seng
    Karim, Ahmad Helmy Abdul
    Sayuti, Khairil Amir
    Tan, Tian-Swee
    Kadir, Mohammed Rafiq Abdul
    INTERNATIONAL CONFERENCE ON MATHEMATICS, ENGINEERING AND INDUSTRIAL APPLICATIONS 2016 (ICOMEIA2016), 2016, 1775
  • [5] Renal perfusion in acute kidney injury with DCE-MRI: Deconvolution analysis versus two-compartment filtration model
    Zoellner, Frank G.
    Zimmer, Fabian
    Klotz, Sarah
    Hoeger, Simone
    Schad, Lothar R.
    MAGNETIC RESONANCE IMAGING, 2014, 32 (06) : 781 - 785
  • [6] A theoretical study of the robustness of the isovolume calibration method for a two-compartment model of breathing, based on an analysis of the connected cylinders model
    Augousti, AT
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 283 - 291
  • [7] Color-Based Segmentation vs. Stereology: A Simple Comparison Between Two Semi-Automated Methods of Image Analysis for the Quantification of Collagen
    Salinas, Paulo
    Sanhueza, Jorge
    Sandoval, Carlos
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2018, 36 (03): : 1118 - 1123
  • [8] Semi-automated relative quantification of cell culture contamination with mycoplasma by Photoshop-based image analysis on immunofluorescence preparations
    Kumar, Ashok
    Yerneni, Lakshmana K.
    BIOLOGICALS, 2009, 37 (01) : 55 - 60
  • [9] Functional imaging of acute kidney injury at 3 Tesla: Investigating multiple parameters using DCE-MRI and a two-compartment filtration model
    Zoellner, Frank G.
    Zimmer, Fabian
    Klotz, Sarah
    Hoeger, Simone
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (01): : 58 - 65
  • [10] Semi-automated impact device based on human behaviour recognition model for in-service modal analysis
    Zahid, Fahad Bin
    Ong, Zhi Chao
    Khoo, Shin Yee
    Mohd Salleh, Mohd Fairuz
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (02)