Towards disposable sensors for drug quality control: Dextromethorphan screen-printed electrodes

被引:25
作者
Khaled, Elmorsy [1 ]
Hassan, H. N. A. [1 ]
Mohamed, Gehad G. [2 ]
Seleim, Aly Eldin A. [3 ]
机构
[1] Natl Res Ctr, Microanal Lab, Giza 14211, Egypt
[2] Cairo Univ, Fac Sci, Dept Chem, Giza 12613, Egypt
[3] Cairo Univ, Fac Med, Crit Care Dept, Giza 12613, Egypt
关键词
disposable screen-printed carbon electrode; potentiometry; dextromethorphan; flow injection analysis (FIA); pharmaceutical preparations; ION-SELECTIVE ELECTRODES; INJECTION POTENTIOMETRIC DETERMINATION; CARBON-PASTE ELECTRODES; PVC ELECTRODES; MEMBRANE; URINE;
D O I
10.1002/dta.159
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, reliable, and reproducible method for mass production of disposable sensors using screen-printing technology is described. Homemade printing has been characterized and optimized on the basis of effects of the modifier and plasticizers. The fabricated bi-electrode potentiometric strip containing both working and reference electrode was used as dextromethorphan (DXM) sensor. The proposed sensors worked satisfactorily in the concentration range from 10(-5) to 10(-2) mol L-1 with detection limit reaching 6 x 10(-6) mol L-1 and adequate shelf life of 8 months. DXM was determined in pharmaceutical formulations under batch and flow injection analysis (FIA) conditions with sampling output 120 h(-1). Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:424 / 429
页数:6
相关论文
共 32 条
[1]   Novel lipoate-selective membrane sensor for the flow injection determination of α-lipoic acid in pharmaceutical preparations and urine [J].
Abbas, M. N. ;
Radwan, A. A. .
TALANTA, 2008, 74 (05) :1113-1121
[2]   A novel solid-contact sensor for flow injection determination of verapamil in pharmaceutical formulations and urine [J].
Abbas, Mohammad N. ;
Amer, Hend S. .
CURRENT PHARMACEUTICAL ANALYSIS, 2008, 4 (02) :90-100
[3]   Flow injection potentiometric determination of amantadine HCl [J].
Abdel-Ghani, NT ;
Shoukry, AF ;
Hussein, SH .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :601-611
[4]   Direct determination of triamterene by potentiometry using a coated wire selective electrode [J].
Arvand, M ;
Mousavi, MF ;
Zanjanchi, MA ;
Shamsipur, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) :975-982
[5]   SINGLE PIECE ALL-SOLID-STATE ION-SELECTIVE ELECTRODE [J].
BOBACKA, J ;
LINDFORS, T ;
MCCARRICK, M ;
IVASKA, A ;
LEWENSTAM, A .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3819-3823
[6]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[7]  
Cosofret V.V., 1992, PHARM APPL MEMBRANE
[8]  
Danet A., 1998, J. Flow Injection Anal, V15, P168
[9]   Recent developments in the field of screen-printed electrodes and their related applications [J].
Dominguez Renedo, O. ;
Alonso-Lomillo, M. A. ;
Arcos Martinez, M. J. .
TALANTA, 2007, 73 (02) :202-219
[10]   Some recent designs and developments of screen-printed carbon electrochemical sensors/biosensors for biomedical, environmental, and industrial analyses [J].
Hart, JP ;
Crew, A ;
Crouch, E ;
Honeychurch, KC ;
Pemberton, RM .
ANALYTICAL LETTERS, 2004, 37 (05) :789-830