Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe pre-eclampsia

被引:29
作者
Dyer, R. A. [1 ]
Piercy, J. L. [1 ,2 ]
Reed, A. R. [1 ]
Strathie, G. W. [2 ]
Lombard, C. J. [5 ]
Anthony, J. A. [3 ,4 ]
James, M. F. [1 ]
机构
[1] Univ Cape Town, Dept Anaesthesia D23, ZA-7925 Cape Town, South Africa
[2] Univ Cape Town, Dept Crit Care, ZA-7925 Cape Town, South Africa
[3] Univ Cape Town, Dept Obstet & Gynaecol, ZA-7925 Cape Town, South Africa
[4] Groote Schuur Hosp, ZA-7925 Cape Town, South Africa
[5] MRC, Biostat Unit, Cape Town, South Africa
关键词
cardiac output; monitoring; pre-eclampsia; INJECTION; AGREEMENT; PRECISION; PRESSURE;
D O I
10.1093/bja/aeq292
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. This study compared cardiac output (CO) measurements derived from pulse waveform analysis with values obtained by thermodilution (TD), in patients with postpartum complications of severe pre-eclampsia. Methods. Eighteen patients were recruited, 24-96 h post-delivery. After central venous calibration of the pulse waveform analysis monitor (LiDCOplus), CO readings were compared with those obtained by the TD method and repeated twice at 15 min intervals. The comparison was repeated after peripheral venous calibration. Further comparisons were made in eight patients at 120 and 240 min after peripheral venous calibration. Results. Data were pooled for measurements at 0, 15, and 30 min after calibration. For the comparison between TD and LiDCOplus using central venous calibration, TD exhibited a significant positive bias of 0.58 litre min(-1) [95% confidence interval (CI): 0.77 to 0.39]. After peripheral venous calibration, there was no significant bias [0.16 litre min(-1) (95% CI: -0.37 to 0.06)]. The estimated limits of agreement for central and peripheral venous calibrations were -2.12 to 0.96 and -1.50 to 1.20 litre min(-1), respectively. When comparing LiDCOplus and TD, there was no time-based effect at 120 or 240 min post-peripheral calibration. Conclusions. Central and peripheral venous calibrations of the LiDCOplus monitor were associated with clinically insignificant bias when compared with TD. Limits of agreement were within the recommendation of 30% for acceptance of a new CO technique when compared with current reference methods. This form of minimally invasive CO monitoring may have a valuable role in obstetric critical care.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 16 条
  • [1] *AM COLL OBST GYN, 1993, INT J GYNECOL OBSTET, V42, P199
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique
    Cecconi, M.
    Dawson, D.
    Grounds, R. M.
    Rhodes, A.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (03) : 498 - 504
  • [4] A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients
    Cecconi M.
    Fawcett J.
    Grounds R.M.
    Rhodes A.
    [J]. BMC Anesthesiology, 8 (1)
  • [5] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [6] Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery
    Dyer, Robert A.
    Reed, Anthony R.
    van Dyk, Dominique
    Arcache, Michelle J.
    Hodges, Owen
    Lombard, Carl J.
    Greenwood, Jaime
    James, Michael F.
    [J]. ANESTHESIOLOGY, 2009, 111 (04) : 753 - 765
  • [7] Lithium dilution cardiac output measurement: A clinical assessment of central venous and peripheral venous indicator injection
    Garcia-Rodriguez, C
    Pittman, J
    Cassell, CH
    Sum-Ping, J
    El-Moalem, H
    Young, C
    Mark, JB
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (10) : 2199 - 2204
  • [8] Hamilton TT, 2002, ANN THORAC SURG, V74, pS1408
  • [9] A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride
    Jonas, MM
    Kelly, FE
    Linton, RAF
    Band, DM
    O'Brien, TK
    Linton, NWF
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (7-8) : 525 - 528
  • [10] Small sample inference for fixed effects from restricted maximum likelihood
    Kenward, MG
    Roger, JH
    [J]. BIOMETRICS, 1997, 53 (03) : 983 - 997