Bone-like polyethelyne burr-hole cover

被引:13
作者
Dujovny, M
Aviles, A
Cuevas, P
机构
[1] Rush Univ, Med Ctr, Dept Surg, Chicago, IL USA
[2] Wayne State Univ, Dept Neurol Surg, Detroit, MI USA
[3] Hosp Univ Ramon & Cajal, Dept Pathol, Madrid, Spain
关键词
high-density polyethylene; craniectomy; craniostomy; cranioplasty; burr hole;
D O I
10.1179/016164105X22138
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Several materials are available for covering burr holes but none of them are ideal with respect to biocompatibility, strength and morbidity. With these properties in mind, our objective was to design a porous polyethylene device, which looked like bone and provides protection and cosmesis while being quick and easy to apply. Methods and Materials/Results: A burr-hole cover was created to cover small cranial defects and craniostomies. Using high-density polyethylene, this cover was designed to resemble the bony structure of the skull. Its porous architecture allows for tissue ingrowth and bony integration. It consists of a cylinder which fits into the burr hole and a cap which can be sutured or anchored with titanium screws. Conclusions: The 'bone-like' burr-hole cover provides adequate protection, biocompatibility and cosmesis and is simple to use. Alternative implants can be toxic to surrounding tissues, costly and time consuming to apply. This high-density polyethylene cover is compatible with surrounding tissue as well as being of a porous nature and the material it is made from offers high tensile strength for adequate protection.
引用
收藏
页码:333 / 334
页数:2
相关论文
共 9 条
[1]   Hormone-like effects of fibroblast growth factors (FGFs) in the nervous system [J].
Cuevas, P .
SURGICAL NEUROLOGY, 1998, 50 (06) :571-573
[2]   Cranioplasty: Cosmetic or therapeutic? [J].
Dujovny, M ;
Aviles, A ;
Agner, C ;
Fernandez, P ;
Charbel, FT .
SURGICAL NEUROLOGY, 1997, 47 (03) :238-241
[3]   Syndrome of the trephined: theory and facts [J].
Dujovny, M ;
Agner, C ;
Aviles, A .
CRITICAL REVIEWS IN NEUROSURGERY, 1999, 9 (05) :271-278
[4]   Burr hole cover for ventriculoperitoneal shunts and ventriculostomy:: Technical note [J].
Dujovny, M ;
Dujovny, N ;
Viñas, F ;
Park, HK ;
Lopez, F .
NEUROLOGICAL RESEARCH, 2002, 24 (05) :483-484
[5]   Post-cranioplasty cerebrospinal fluid hydrodynamic changes: Magnetic resonance imaging quantitative analysis [J].
Dujovny, M ;
Fernandez, P ;
Alperin, N ;
Betz, W ;
Misra, M ;
Mafee, M .
NEUROLOGICAL RESEARCH, 1997, 19 (03) :311-316
[6]   Biomechanical properties of high-density polyethylene for pterional prosthesis [J].
Park, HK ;
Dujovny, M ;
Diaz, FG ;
Guthikonda, M .
NEUROLOGICAL RESEARCH, 2002, 24 (07) :671-676
[7]   Biomechanical properties of calvarium prosthesis [J].
Park, HK ;
Dujovny, M ;
Agner, C ;
Diaz, FG .
NEUROLOGICAL RESEARCH, 2001, 23 (2-3) :267-276
[8]  
Rutkow IM, 1997, ARCH SURG-CHICAGO, V132, P983
[9]   Autogenic bone plug to seal burr holes: technical note. [J].
Vialogo, JGG .
ARQUIVOS DE NEURO-PSIQUIATRIA, 1999, 57 (04) :1041-1045