Investigation of endogenous soybean food allergens by using a 2-dimensional gel electrophoresis approach

被引:27
|
作者
Rouquie, David [1 ]
Capt, Annabelle [1 ]
Eby, William H.
Sekar, Vaithilingam [2 ]
Herouet-Guicheney, Corinne [1 ]
机构
[1] Bayer SAS, Sophia Antipolis, France
[2] MS Technol Ames, Ames, IA USA
关键词
Genetically modified crop; Risk assessment; Allergenicity; Soybean allergen; 2-Dimensional gel electrophoresis; MODIFIED CROPS; SOY ALLERGY; PROTEIN; IDENTIFICATION; GLYCININ;
D O I
10.1016/j.yrtph.2010.09.013
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
As part of the safety assessment of genetically modified (GM) soybean, 2-dimensional gel electrophoresis analyses were performed with the isoxaflutole and glyphosate tolerant soybean FG72, its non-GM near-isogenic counterpart (Jack) and three commercial non-GM soybean lines. The objective was to compare the known endogenous human food allergens in seeds in the five different soybean lines in order to evaluate any potential unintended effect(s) of the genetic modification. In total, 37 protein spots representing five well known soybean food allergen groups were quantified in each genotype. Qualitatively, all the allergenic proteins were detected in the different genetic backgrounds. Quantitatively, among 37 protein spots, the levels of accumulation of three allergens were slightly lower in the GM soybean than in the non-GM counterparts. Specifically, while the levels of two of these three allergens fell within the normal range of variation observed in the four non-GM varieties, the level of the third allergen was slightly below the normal range. Overall, there was no significant increase in the level of allergens in FG72 soybean seeds. Therefore, the FG72 soybean can be considered as safe as its non-GM counterpart with regards to endogenous allergenicity. Additional research is needed to evaluate the biological variability in the levels of endogenous soybean allergens and the correlation between level of allergens and allergenic potential in order to improve the interpretation of these data in the safety assessment of GM soybean context. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:S47 / S53
页数:7
相关论文
共 50 条
  • [12] 2-DIMENSIONAL AGAROSE-GEL ELECTROPHORESIS WITHOUT GEL MANIPULATION
    SERWER, P
    ANALYTICAL BIOCHEMISTRY, 1985, 144 (01) : 172 - 178
  • [13] Analysis of pressure response of human cells using 2-dimensional gel electrophoresis
    Takano, KJ
    Takano, T
    Yamanouchi, Y
    Katoh, Y
    HIGH PRESSURE RESEARCH, 2002, 22 (3-4) : 743 - 746
  • [14] Investigation of Human Testis Protein Heterogeneity Using 2-Dimensional Electrophoresis
    Guo, Xuejiang
    Zhao, Chun
    Wang, Fuqiang
    Zhu, Yefei
    Cui, Yugui
    Zhou, Zuomin
    Huo, Ran
    Sha, Jiahao
    JOURNAL OF ANDROLOGY, 2010, 31 (04): : 419 - 429
  • [15] HETEROGENEITY OF NUCLEOLAR PROTEINS ON 2-DIMENSIONAL GEL-ELECTROPHORESIS
    ORRICK, L
    KLOMP, R
    OLSON, M
    BUSCH, H
    STARBUCK, W
    PROCEEDINGS OF THE AMERICAN ASSOCIATION FOR CANCER RESEARCH, 1973, 14 (MAR): : 18 - &
  • [16] 2-DIMENSIONAL GEL-ELECTROPHORESIS OF WHEAT GLIADIN PROTEINS
    MECHAM, DK
    KASARDA, DD
    CEREAL FOODS WORLD, 1976, 21 (08) : 430 - 430
  • [17] HIGHLY EFFICIENT APPARATUS FOR 2-DIMENSIONAL GEL-ELECTROPHORESIS
    SHISHKIN, SS
    VOLODINA, TV
    PONTRYAGINA, NY
    DEBOV, SS
    VOPROSY MEDITSINSKOI KHIMII, 1984, 30 (06): : 126 - 131
  • [18] IMAGE-PROCESSING OF 2-DIMENSIONAL GEL-ELECTROPHORESIS
    PLEISSNER, KP
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, 1989, : 229 - 236
  • [19] 2-DIMENSIONAL GEL-ELECTROPHORESIS OF CIRCULAR DNA TOPOISOMERS
    BOWATER, R
    ABOULELA, F
    LILLEY, DMJ
    METHODS IN ENZYMOLOGY, 1992, 212 : 105 - 120
  • [20] IDENTIFICATION OF PERILYMPH PROTEINS BY 2-DIMENSIONAL GEL-ELECTROPHORESIS
    PAUGH, DR
    TELIAN, SA
    DISHER, MJ
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1991, 104 (04) : 517 - 525