Uncertainty Evaluation of an In-Flight Absolute Radiometric Calibration Using a Statistical Monte Carlo Method

被引:14
作者
Chen, Wei [1 ]
Zhao, Haimeng [2 ]
Li, Zhanqing [3 ]
Jing, Xin [2 ]
Yan, Lei [2 ]
机构
[1] China Univ Min & Technol, Coll Geosci & Surveying Engn, Beijing 100083, Peoples R China
[2] Peking Univ, Inst Remote Sensing & Geog Informat Syst, Beijing 100871, Peoples R China
[3] Univ Maryland, Earth Syst Sci Interdisciplinary Ctr, College Pk, MD 20742 USA
来源
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING | 2015年 / 53卷 / 05期
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
Radiometric calibration; radiometric targets; reflectance-based method; uncertainty; VICARIOUS CALIBRATION; REFLECTANCE; ASTER; MISR;
D O I
10.1109/TGRS.2014.2366779
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The absolute radiometric calibration of remote sensing sensors is crucial to the accurate retrieval of biogeophysical parameters through remote sensing. The radiometric calibration uncertainty is the index that describes the reliability of a calibration result and is usually empirically determined by assuming that all of the factors involved are independent of each other. Through a field campaign carried out in Inner Mongolia, China, which aimed to accurately calibrate remote sensing sensors, we developed a Monte Carlo method that statistically evaluates the radiometric calibration uncertainty. From Monte Carlo simulations, it was revealed that the overall uncertainty is much smaller than the root sum of squares of each factor, suggesting that there is some negative correlation among some of the factors. For a surface with a low reflectance (similar to 5%), the radiometric calibration uncertainty was similar to 7.0%, whereas for a surface with a reflectance larger than 20%, the uncertainty was stable at similar to 3.0%. This result suggests that the quality of remote sensing data should be carefully examined for surfaces with a low reflectance.
引用
收藏
页码:2925 / 2934
页数:10
相关论文
共 50 条
  • [1] In-Flight Absolute Radiometric Calibration of UAV Multispectral Sensor
    Chen Wei
    Yan Lei
    Gou Zhi-yang
    Zhao Hong-ying
    Liu Da-ping
    Duan Yi-ni
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (12) : 3169 - 3174
  • [2] In-flight absolute radiometric calibration of MODIS using the irradiance-based method
    Wei, Wei
    Li, Xin
    Zhao, Chun-yan
    Qiu, Gang-gang
    Zheng, Xiao-bing
    HYPERSPECTRAL REMOTE SENSING APPLICATIONS AND ENVIRONMENTAL MONITORING AND SAFETY TESTING TECHNOLOGY, 2016, 10156
  • [3] In-Flight Absolute Radiometric Calibration of UAV Hyperspectral Camera and Its Validation Analysis
    Gou Zhi-yang
    Yan Lei
    Chen Wei
    Jing Xin
    Yin Zhong-yi
    Duan Yi-ni
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (02) : 430 - 434
  • [4] Evaluation of Humidity Sensor Calibration Uncertainty by Monte Carlo Method
    Wei, M.
    Wen, C.
    Li, C.
    Miao, J.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2024, 39 (03): : 625 - 635
  • [5] Absolute Radiometric Calibration of Landsat Using a Pseudo Invariant Calibration Site
    Helder, Dennis
    Thome, Kurtis J.
    Mishra, Nischal
    Chander, Gyanesh
    Xiong, Xiaoxiong
    Angal, Amit
    Choi, Taeyoung
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03): : 1360 - 1369
  • [6] A first in-flight absolute calibration of the Chilean Earth Observation Satellite
    Mattar, C.
    Hernandez, J.
    Santamaria-Artigas, A.
    Duran-Alarcon, C.
    Olivera-Guerra, L.
    Inzunza, M.
    Tapia, D.
    Escobar-lavin, E.
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2014, 92 : 16 - 25
  • [7] Designing an in-flight airborne calibration site using experience from vicarious radiometric satellite calibration
    Livens, Stefan
    Debruyn, Walter
    Sterckx, Sindy
    Reusen, Ils
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XV, 2011, 8176
  • [8] A new methodology for in-flight radiometric calibration of the MIVIS imaging sensor
    Gianinetto, Marco
    Lechi, Giovanmaria
    ANNALS OF GEOPHYSICS, 2006, 49 (01) : 65 - 70
  • [9] New method of in-flight absolute calibration for thermal infrared channals of satellite sensors
    Tong, JJ
    Qiu, KM
    Li, XW
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2005, 24 (04) : 277 - 280
  • [10] Uncertainty Evaluation using the Monte-Carlo Method for the Calibration of Four Terminal Pair Air Capacitance Standards
    Lee, Hyung-Kew
    Kim, Dan Bee
    Kim, Wan-Seop
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,