Avidin-biotin ELISA for measurement of prothrombin in human plasma

被引:10
|
作者
Koldas, M
Uras, F
机构
[1] Marmara Univ, Fac Pharm, Dept Biochem, TR-80010 Istanbul, Turkey
[2] Haseki Hosp, Biochem Lab, Istanbul, Turkey
关键词
ELISA; avidin-biotin; nephelometry; prothrombin; antibody preparation; IgG purification; liver disease;
D O I
10.1016/S0049-3848(01)00257-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study, IgG was partially purified from rabbit antisera against human normal prothrombin. The presence of antibodies against prothrombin was shown by Ouchterlony's double immunodiffusion method. This IgC was adsorbed to microwells and an enzyme-linked immunosorbent assay (ELISA) method was developed by using biotinylated prothrombin. We used alkaline phosphatase as the labeling enzyme. Plasma prothrombin concentrations in 30 healthy individuals and 15 patients with liver cirrhosis were measured using this ELISA method. Prothrombin levels of the cirrhotic patients (61 +/- 36 mug/ml) were significantly lower than those of the control values (117 +/- 43 mug/ml) (P < .001). In addition to the ELISA method in the same samples, we assayed prothrombin levels by nephelometry and prothrombin activities using staphylocoagulase and chromogenic substrate. With nephelometry, in healthy individuals, a mean value of 104 +/- 17 mug/ml and, in cirrhotic patients, a mean value of 51 +/- 26 mug/ml of prothrombin levels were detected. The prothrombin activities were 10532 +/- 2429 and 2433 +/- 330 U/l, respectively. In both methods, the prothrombin values of cirrhotic patients were also significantly lower than those of the healthy individuals (P<.001). The correlation coefficient between ELISA and nephelometry was r = .90, P <less than> .01, and between ELISA and the amidolytic assay was v = .69, P < .01. Prothrombin times (PT) of cirrhotic patients (18.5 +/- 2.3 s) were significantly longer and albumin (2.3 +/- 0.5 g/dl) levels were significantly lower than those of normal values (P<.001). PT were negatively correlated with prothrombin levels assayed by ELISA (r = -.59, P <less than> .01). This enzyme immunoassay technique can be used to measure prothrombin levels in plasma. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [21] Use of ELISA, IFA, and avidin-biotin staining for the diagnosis of bovine genital campylobacteriosis
    Ak, S
    Turan, N
    Ak, K
    Ileri, IK
    Ilgaz, A
    TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, 2000, 24 (02): : 113 - 121
  • [22] HEAT STABILITY OF AVIDIN + AVIDIN-BIOTIN COMPLEX + INFLUENCE OF IONIC STRENGTH ON AFFINITY OF AVIDIN FOR BIOTIN
    WEI, RD
    WRIGHT, LD
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1964, 117 (02): : 341 - &
  • [23] THE FLEXIBILITY OF THE AVIDIN-BIOTIN TECHNIQUE IN IMMUNOASSAYS
    VILJA, P
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1162 - 1163
  • [24] AVIDIN-BIOTIN SYSTEM IN ENZYME IMMUNOASSAYS
    TERNYNCK, T
    AVRAMEAS, S
    METHODS IN ENZYMOLOGY, 1990, 184 : 469 - 481
  • [25] EFFECTS OF DETERGENTS ON AVIDIN-BIOTIN INTERACTION
    ROSS, SE
    CARSON, SD
    FINK, LM
    BIOTECHNIQUES, 1986, 4 (04) : 350 - 354
  • [26] The liberation of biotin from the avidin-biotin complex (AB)
    Gyorgy, P
    Rose, CS
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1943, 53 (01): : 55 - 57
  • [27] Avidin-biotin technology in targeted therapy
    Lesch, Hanna P.
    Kaikkonen, Minna U.
    Pikkarainen, Jere T.
    Yla-Herttuala, Seppo
    EXPERT OPINION ON DRUG DELIVERY, 2010, 7 (05) : 551 - 564
  • [28] FLUOROMETRIC ASSAY FOR AVIDIN-BIOTIN INTERACTION
    MOCK, DM
    HOROWITZ, P
    METHODS IN ENZYMOLOGY, 1990, 184 : 234 - 240
  • [29] INVESTIGATIONS OF AVIDIN-BIOTIN IN RADIOPHARMACEUTICAL DESIGN
    HNATOWICH, DJ
    RUSCKOWSKI, M
    VIRZI, F
    DOHERTY, PW
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1986, 23 (10-12): : 1293 - 1293
  • [30] AVIDIN-BIOTIN MEDIATED IMMUNOASSAYS - OVERVIEW
    WILCHEK, M
    BAYER, EA
    METHODS IN ENZYMOLOGY, 1990, 184 : 467 - 469