Avidin-biotin ELISA for measurement of prothrombin in human plasma

被引:10
|
作者
Koldas, M
Uras, F
机构
[1] Marmara Univ, Fac Pharm, Dept Biochem, TR-80010 Istanbul, Turkey
[2] Haseki Hosp, Biochem Lab, Istanbul, Turkey
关键词
ELISA; avidin-biotin; nephelometry; prothrombin; antibody preparation; IgG purification; liver disease;
D O I
10.1016/S0049-3848(01)00257-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study, IgG was partially purified from rabbit antisera against human normal prothrombin. The presence of antibodies against prothrombin was shown by Ouchterlony's double immunodiffusion method. This IgC was adsorbed to microwells and an enzyme-linked immunosorbent assay (ELISA) method was developed by using biotinylated prothrombin. We used alkaline phosphatase as the labeling enzyme. Plasma prothrombin concentrations in 30 healthy individuals and 15 patients with liver cirrhosis were measured using this ELISA method. Prothrombin levels of the cirrhotic patients (61 +/- 36 mug/ml) were significantly lower than those of the control values (117 +/- 43 mug/ml) (P < .001). In addition to the ELISA method in the same samples, we assayed prothrombin levels by nephelometry and prothrombin activities using staphylocoagulase and chromogenic substrate. With nephelometry, in healthy individuals, a mean value of 104 +/- 17 mug/ml and, in cirrhotic patients, a mean value of 51 +/- 26 mug/ml of prothrombin levels were detected. The prothrombin activities were 10532 +/- 2429 and 2433 +/- 330 U/l, respectively. In both methods, the prothrombin values of cirrhotic patients were also significantly lower than those of the healthy individuals (P<.001). The correlation coefficient between ELISA and nephelometry was r = .90, P <less than> .01, and between ELISA and the amidolytic assay was v = .69, P < .01. Prothrombin times (PT) of cirrhotic patients (18.5 +/- 2.3 s) were significantly longer and albumin (2.3 +/- 0.5 g/dl) levels were significantly lower than those of normal values (P<.001). PT were negatively correlated with prothrombin levels assayed by ELISA (r = -.59, P <less than> .01). This enzyme immunoassay technique can be used to measure prothrombin levels in plasma. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [1] AN AVIDIN-BIOTIN ELISA FOR THE MEASUREMENT OF SERUM AND SECRETORY IGD
    PLEBANI, A
    AVANZINI, MA
    MASSA, M
    UGAZIO, AG
    JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 71 (02) : 133 - 140
  • [2] AN AVIDIN-BIOTIN ELISA FOR THE MEASUREMENT OF MITOCHONDRIAL ASPARTATE-AMINOTRANSFERASE IN HUMAN SERUM
    VARASTEH, A
    WELLMAN, M
    ARTUR, Y
    SCHIELE, F
    SIEST, G
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 128 (02) : 203 - 209
  • [3] AN AVIDIN-BIOTIN ELISA ASSAY FOR THE MEASUREMENT OF DENOVO HUMAN IGE SYNTHESIS IN CULTURE SUPERNATANTS
    ALEVY, YG
    BLYNN, CM
    JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 87 (02) : 273 - 281
  • [4] BIOTIN AND THE AVIDIN-BIOTIN COMPLEX
    HERTZ, R
    PHYSIOLOGICAL REVIEWS, 1946, 26 (04) : 479 - 494
  • [5] AVIDIN-BIOTIN RADIOIMMUNOASSAY FOR HUMAN ROTAVIRUS
    YOLKEN, RH
    JOURNAL OF INFECTIOUS DISEASES, 1983, 148 (05): : 942 - 942
  • [6] ESTIMATION OF FERRITIN BY CONVENTIONAL ELISA AND ITS AVIDIN-BIOTIN MODIFICATION
    BHARGAVA, M
    KUMAR, R
    INDIAN JOURNAL OF MEDICAL RESEARCH, 1986, 84 : 445 - 447
  • [7] AN AVIDIN-BIOTIN BASED ELISA FOR QUANTITATION OF ANTIBODY TO BACTERIAL POLYSACCHARIDES
    SUTTON, A
    VANN, WF
    KARPAS, AB
    STEIN, KE
    SCHNEERSON, R
    JOURNAL OF IMMUNOLOGICAL METHODS, 1985, 82 (02) : 215 - 224
  • [8] THE AVIDIN-BIOTIN EQUILIBRIUM
    LAUNER, HF
    FRAENKELCONRAT, H
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1951, 193 (01) : 125 - 132
  • [9] THE AVIDIN-BIOTIN SYSTEM
    MORRIS, RE
    SAELINGER, CB
    IMMUNOLOGY TODAY, 1984, 5 (05): : 127 - 127
  • [10] AN AVIDIN-BIOTIN IMMUNOASSAY FOR THE MEASUREMENT OF FACTOR-VIII
    ROCK, GA
    GANZ, PR
    PANG, AS
    TACKABERRY, ES
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1985, 8 (03): : A125 - A125