Near-IR absorption of water vapor: Pressure dependence of line strengths and an upper limit for continuum absorption

被引:11
|
作者
Aldener, M
Brown, SS
Stark, H
Daniel, JS
Ravishankara, AR
机构
[1] NOAA, Aeron Lab, Boulder, CO 80305 USA
[2] Univ Colorado, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[3] Univ Colorado, Dept Chem & Biochem, Boulder, CO 80309 USA
关键词
water vapor; linestrength; continuum; near-IR; cavity ringdown;
D O I
10.1016/j.jms.2005.04.011
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Water vapor absorption cross-sections in the near-infrared region (10500-10800 cm(-1)) were measured using cavity ringdown spectroscopy. Linestrengths were measured for several absorption lines around 10604 cm(-1) (943 nm) between 500 and 850 Torr of N-2 and found to be independent of pressure. Our measured linestrengths of these individual lines agree well with values from databases such as HITRAN and the ESA-WVR, which are currently used for atmospheric calculations, but the integrated strength over the entire measured spectral region is slightly larger than that contained in these databases. Water vapor pressure-broadening coefficients due to nitrogen were also estimated from these measurements. The absorption due to water vapor continuum was determined to be less than (9.2 +/- 0.2) x 10(-27) cm(2) molecule(-1) at 11500 cm(-1). This measured upper limit, though larger than the estimated values from continuum models, would not contribute significantly to the calculated radiation absorption in this wavelength region. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [1] Evaluation of suitable spectral intervals for near-IR laboratory detection of water vapour continuum absorption
    Ptashnik, Igor V.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2007, 108 (01): : 146 - 160
  • [2] Upper limits for absorption by water vapor in the near-UV
    Wilson, Eoin M.
    Wenger, John C.
    Venables, Dean S.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2016, 170 : 194 - 199
  • [3] Atmospheric absorption of terahertz radiation and water vapor continuum effects
    Slocum, David M.
    Slingerland, Elizabeth J.
    Giles, Robert H.
    Goyette, Thomas M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 127 : 49 - 63
  • [4] Water vapor continuum:: absorption measurements at 350 GHz and model calculations
    Kuhn, T
    Bauer, A
    Godon, M
    Buehler, SA
    Künzi, K
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2002, 74 (05): : 545 - 562
  • [5] Measurement of water vapor line strengths in the 1.4-2.7 μm range by tunable diode laser absorption spectroscopy
    Pogany, Andrea
    Klein, Alexander
    Ebert, Volker
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 165 : 108 - 122
  • [6] Inexpensive near-IR sun photometer for measuring total column water vapor
    Brooks, David R.
    Mims, Forrest M., III
    Roettger, Richard
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2007, 24 (07) : 1268 - 1276
  • [7] POTASSIUM VAPOR NEAR-IR LASER LINE REJECTION FILTER FOR RAMAN-SPECTROSCOPY
    PELLETIER, MJ
    APPLIED SPECTROSCOPY, 1993, 47 (01) : 69 - 74
  • [8] Dimer Absorption within Water Vapor Bands in the IR Region
    Yu. V. Bogdanova
    T. E. Klimeshina
    O. B. Rodimova
    Atmospheric and Oceanic Optics, 2020, 33 : 134 - 140
  • [9] Dimer Absorption within Water Vapor Bands in the IR Region
    Bogdanova, Yu. V.
    Klimeshina, T. E.
    Rodimova, O. B.
    ATMOSPHERIC AND OCEANIC OPTICS, 2020, 33 (02) : 134 - 140
  • [10] The continuum of water vapor mixed with methane: Absolute absorption at 239 GHz and linewidth calculations
    Godon, M
    Bauer, A
    Gamache, RR
    JOURNAL OF MOLECULAR SPECTROSCOPY, 2000, 202 (02) : 293 - 302