Technology preview:: X-ray fused with magnetic resonance during invasive cardiovascular procedures

被引:38
作者
Gutierrez, Luis F.
de Silva, Ranil
Ozturk, Cengizhan
Sonmez, Merdim
Stine, Annette M.
Raval, Amish N.
Raman, Venkatesh K.
Sachdev, Vandana
Aviles, Ronnier J.
Waclawiw, Myron A.
McVeigh, Elliot R.
Lederman, Robert J.
机构
[1] NHLBI, Cardiovasc Branch, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[3] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
[4] Bogazici Univ, Inst Biomed Engn, Istanbul, Turkey
[5] NHLBI, Div Intramural Res, NIH, Bethesda, MD 20892 USA
[6] NHLBI, Off Biostat Res, NIH, Bethesda, MD 20892 USA
关键词
catheterization; magnetic resonance imaging; stereotactic surgery; image guided intervention; myocardial biopsy; chronic total occlusion; COMPUTED TOMOGRAPHIC-IMAGES; REAL-TIME; CATHETER ABLATION; SWINE MODEL; LEFT ATRIAL; REGISTRATION; MR; INTERVENTION; MOTION; DEFORMATION;
D O I
10.1002/ccd.21352
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We have developed and validated a system for real-time X-ray fused with magnetic resonance imaging, MRI (XFM), to guide catheter procedures with high spatial precision. Our implementation overlays roadmaps-MRI-derived soft-tissue features of interest-onto conventional X-ray fluoroscopy. We report our initial clinical experience applying XFM, using external fiducial markers, electrocardiogram (ECG)-gating, and automated real-time correction for gantry and table movement. Methods: This prospective case series for technical development was approved by the NHLBI Institutional Review Board and included 19 subjects. Multimodality external fiducial markers were affixed to patients' skin before MRI, which included contrast-enhanced, 3D T1-weighted, or breath-held and ECG-gated 2D steady state free precession imaging at 1.5T. MRI-derived roadmaps were manually segmented while patients were transferred to a calibrated X-ray fluoroscopy system. Image spaces were registered using the fiducial markers and thereafter permitted unrestricted gantry rotation, table panning, and magnification changes. Static and ECG-gated MRI data were transformed from 3D to 2D to correspond with gantry and table position and combined with live X-ray images. Results: Clinical procedures included graft coronary arteriography, right ventricular free-wail biopsy, and iliac and femoral artery recanalization and stenting. MRI roadmaps improved operator confidence, and in the biopsy cases, outperformed the best available alternative imaging modality. Registration errors were increased when external fiducial markers were affixed to more mobile skin positions, such as over the abdomen. Conclusion: XFM using external fiducial markers is feasible during X-ray guided catheter treatments. Multimodality image fusion may prove a useful adjunct to invasive cardiovascular procedures. (c) 2007 Wiley-Liss, Inc.
引用
收藏
页码:773 / 782
页数:10
相关论文
共 22 条
  • [1] X-ray fused with magnetic resonance imaging (XFM) to target endomyocardial injections - Validation in a swine model of myocardial infarction
    de Silva, Ranil
    Gutierrez, Luis F.
    Raval, Amish N.
    McVeigh, Elliot R.
    Ozturk, Cengizhan
    Lederman, Robert J.
    [J]. CIRCULATION, 2006, 114 (22) : 2342 - 2350
  • [2] Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time
    Dickfeld, T
    Calkins, H
    Zviman, M
    Kato, R
    Meininger, G
    Lickfett, L
    Berger, R
    Halperin, H
    Solomon, SB
    [J]. CIRCULATION, 2003, 108 (19) : 2407 - 2413
  • [3] Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
    Dong, J
    Calkins, H
    Solomon, SB
    Lai, SH
    Dalal, D
    Lardo, A
    Brem, E
    Preiss, A
    Berger, RD
    Halperin, H
    Dickfeld, T
    [J]. CIRCULATION, 2006, 113 (02) : 186 - 194
  • [4] Cardiac three-dimensional magnetic resonance imaging and fluoroscopy merging -: A new approach for electroanatomic mapping to assist catheter ablation
    Ector, J
    De Buck, S
    Adams, J
    Dymarkowski, S
    Bogaert, J
    Maes, F
    Heidbüchel, H
    [J]. CIRCULATION, 2005, 112 (24) : 3769 - 3776
  • [5] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [6] Rotational angiography (RA) and three-dimensional imaging (3-DRA): an available clinical tool
    Garcia, Joel A.
    Chen, James
    Hansgen, Adam
    Wink, Onno
    Movassaghi, Babak
    Messenger, John C.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (01) : 9 - 13
  • [7] Distortion correction, calibration, and registration:: Towards an integrated MR and X-ray interventional suite
    Gutiérrez, LF
    Shechter, G
    Lederman, RJ
    McVeigh, ER
    Ozturk, C
    [J]. MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 146 - 156
  • [8] Tissue deformation and shape models in image-guided interventions: a discussion paper
    Hawkes, DJ
    Barratt, D
    Blackall, JM
    Chan, C
    Edwards, PJ
    Rhode, K
    Penney, GP
    McClelland, J
    Hill, DLG
    [J]. MEDICAL IMAGE ANALYSIS, 2005, 9 (02) : 163 - 175
  • [9] Reliability in multi-site structural MRI studies: Effects of gradient non-linearity correction on phantom and human data
    Jovicich, J
    Czanner, S
    Greve, D
    Haley, E
    van der Kouwe, A
    Gollub, R
    Kennedy, D
    Schmitt, F
    Brown, G
    MacFall, J
    Fischl, B
    Dale, A
    [J]. NEUROIMAGE, 2006, 30 (02) : 436 - 443
  • [10] A study of the motion and deformation of the heart due to respiration
    McLeish, K
    Hill, DLG
    Atkinson, D
    Blackall, JM
    Razavi, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1142 - 1150