Postoperative Changes in In Vivo Measured Friction in Total Hip Joint Prosthesis during Walking

被引:24
作者
Damm, Philipp [1 ]
Bender, Alwina [1 ]
Bergmann, Georg [1 ]
机构
[1] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
TELEMETRY SYSTEM; CONTACT FORCES; PART; LUBRICATION; WEAR; ARTHROPLASTY; REPLACEMENTS; IMPLANTS; TRIBOLOGY; SIMULATOR;
D O I
10.1371/journal.pone.0120438
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Loosening of the artificial cup and inlay is the most common reasons for total hip replacement failures. Polyethylene wear and aseptic loosening are frequent reasons. Furthermore, over the past few decades, the population of patients receiving total hip replacements has become younger and more active. Hence, a higher level of activity may include an increased risk of implant loosening as a result of friction-induced wear. In this study, an instrumented hip implant was used to measure the contact forces and friction moments in vivo during walking. Subsequently, the three-dimensional coefficient of friction in vivo was calculated over the whole gait cycle. Measurements were collected from ten subjects at several time points between three and twelve months postoperative. No significant change in the average resultant contact force was observed between three and twelve months postoperative. In contrast, a significant decrease of up to 47% was observed in the friction moment. The coefficient of friction also decreased over postoperative time on average. These changes may be caused by 'running-in' effects of the gliding components or by the improved lubricating properties of the synovia. Because the walking velocity and contact forces were found to be nearly constant during the observed period, the decrease in friction moment suggests an increase in fluid viscosity. The peak values of the contact force individually varied by 32%-44%. The friction moment individually differed much more, by 110%129% at three and up to 451% at twelve months postoperative. The maximum coefficient of friction showed the highest individual variability, about 100% at three and up to 914% at twelve months after surgery. These individual variations in the friction parameters were most likely due to different 'running-in' effects that were influenced by the individual activity levels and synovia properties.
引用
收藏
页数:15
相关论文
共 46 条
  • [1] Tribology and total hip joint replacement: Current concepts in mechanical simulation
    Affatato, S.
    Spinelli, A.
    Zavalloni, M.
    Mazzega-Fabbro, C.
    Viceconti, A.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2008, 30 (10) : 1305 - 1317
  • [2] [Anonymous], 2012, COMPUT METHOD BIOMEC, DOI DOI 10.1080/10255842.2011.560841
  • [3] Balazs E.A., 1974, Disorders of the Knee, P63
  • [4] Bergen H., 2010, ANN REPORT 2010 NORW
  • [5] INVIVO MEASUREMENT OF HIP-JOINT LOADING .1. PHYSIOTHERAPY
    BERGMANN, G
    ROHLMANN, A
    GRAICHEN, F
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1989, 127 (06): : 672 - 679
  • [6] Frictional heating of total hip implants. Part 1. measurements in patients
    Bergmann, G
    Graichen, F
    Rohlmann, A
    Verdonschot, N
    van Lenthe, GH
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (04) : 421 - 428
  • [7] Hip joint contact forces during stumbling
    Bergmann, G
    Graichen, F
    Rohlmann, A
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2004, 389 (01) : 53 - 59
  • [8] Brand R.A., 1982, The Iowa Orthopaedic Journal, V2, P43
  • [9] Brockett C., 2006, J BIOMEDICAL MAT R B, V81B, P508, DOI DOI 10.1002/JBMB
  • [10] Effect of total hip arthroplasty on recreational and sporting activity
    Chatterji, U
    Ashworth, MJ
    Lewis, PL
    Dobson, PJ
    [J]. ANZ JOURNAL OF SURGERY, 2004, 74 (06) : 446 - 449