Inter-turn faults detection in Induction Motor drives using zero-sequence signal injection

被引:0
|
作者
Otero, M. [1 ]
Bossio, G. R. [1 ]
de la Barrera, P. M. [1 ]
Tyshakin, O. [2 ]
Leidhold, R. [2 ]
机构
[1] Natl Univ Rio Cuarto, Appl Elect Grp, Cordoba, Argentina
[2] Otto von Guericke Univ, Inst Elect Power Syst, Magdeburg, Germany
来源
2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM) | 2018年
关键词
Fault diagnosis; signal injection; stator windings fault detection; induction motor; DIAGNOSIS; STRATEGY;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a strategy for detecting stator inter-turn faults in induction motors (IM), by using a zero sequence high-frequency signal injection. The derivatives of the motor currents are analyzed. The subsequent signal processing allows us to study how these signals change its value as a consequence of stator inter-turn faults. A feature of the strategy is that the zero sequence high-frequency signal is generated by a standard space vector modulation of the IM drive. Experimental results are presented, validating the fault detection strategy.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 50 条
  • [1] Stator inter-turn faults diagnosis in induction motors using zero-sequence signal injectionInspec keywordsOther keywords
    Otero, Marcial
    de la Barrera, Pablo M.
    Bossio, Guillermo R.
    Leidhold, Roberto
    IET ELECTRIC POWER APPLICATIONS, 2020, 14 (14) : 2731 - 2738
  • [2] Broken Rotor Bars Detection in Induction Motor by Using Zero-Sequence Signal Injection
    Bossio, G. R.
    de la Barrera, P. M.
    Otero, M.
    Schallschmidt, T.
    Leidhold, R.
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 1482 - 1487
  • [3] Induction Motor Saliencies Analysis Using Zero-Sequence Signal Injection
    de la Barrera, P. M.
    Bossio, G. R.
    Leidhold, R.
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 518 - 523
  • [4] Application of the zero-sequence voltage component to detect stator winding inter-turn faults in PMSMs
    Urresty, Julio-Cesar
    Riba, Jordi-Roger
    Romeral, Luis
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 89 : 38 - 44
  • [5] Identification of inter-turn insulation faults in induction motor
    Venugopal, Gopu
    Gopalakrishnan, V
    Rajkumar, S. P.
    ENGINEERING COMPUTATIONS, 2020, 37 (02) : 546 - 565
  • [6] Modelling of induction motor inter-turn faults for diagnostics studies
    Raul Cadavid, Diego
    Villada, Fernando
    Velilla, Esteban
    REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2010, (51): : 7 - 15
  • [7] Investigation on Zero-Sequence Signal Injection for Improved Harmonic Performance in Split-Phase Induction Motor Drives
    Rakesh, P. R.
    Narayanan, G.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (04) : 2732 - 2741
  • [8] Anfis approach for the detection of inter-Turn insulation and bearing wear faults in induction motor
    Bailai, M.S.
    Khan, Z.J.
    Suryawanshi, H.M.
    Sonolikar, R.L.
    Journal of the Institution of Engineers (India): Electrical Engineering Division, 2010, 90 (MAR): : 23 - 29
  • [9] The Application of Wavelets for the Detection of Inter-Turn Faults in Induction Machines
    Barendse, P. S.
    Herndler, B.
    Khan, M. A.
    Pillay, P.
    2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, : 1395 - 1401
  • [10] Detection and Discrimination of Simultaneous Stator Inter-Turn and Broken Rotor Bar Faults in Induction Motor
    Sonje, Deepak M.
    Kundu, P.
    Chowdhury, A.