The Effect of Phenylephrine on the Ciliary Muscle and Accommodation

被引:31
作者
Richdale, Kathryn [1 ]
Bailey, Melissa D. [2 ]
Sinnott, Loraine T. [2 ]
Kao, Chiu-Yen [3 ,4 ]
Zadnik, Karla [2 ]
Bullimore, Mark A. [5 ]
机构
[1] SUNY Coll Optometry, New York, NY 10036 USA
[2] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Math, Columbus, OH 43210 USA
[4] Claremont Mckenna Coll, Dept Math & Comp Sci, Claremont, CA 91711 USA
[5] Univ Houston, Coll Optometry, Houston, TX USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
optical coherence tomography; anterior segment imaging; ciliary muscle; accommodation; phenylephrine; presbyopia; HUMAN CRYSTALLINE LENS; HUMAN-EYE; REPEATABILITY; THICKNESS;
D O I
10.1097/OPX.0b013e318269c8d0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To objectively measure changes in the human ciliary muscle dimensions in vivo after instillation of topical phenylephrine, a mydriatic and vasodilating agent. Methods. A cross-sectional study of 25 healthy young adults was conducted. Measurements of pupil size, accommodation, and ciliary muscle thickness were made both before and 30 min after instillation of 1% proparacaine and 2.5% phenylephrine. Accommodation was measured in three ways: subjectively using a push-up technique and Royal Air Force (RAF) rule, and objectively using both the Grand Seiko autorefractor and PowerRefractor. Images of the temporal ciliary muscle were acquired using the Visante Anterior Segment Optical Coherence Tomographer (OCT). Ciliary muscle images were objectively analyzed using a computer-based segmentation technique. Results. Amplitude of accommodation using the push-up test was reduced by about 1 D with phenylephrine (p < 0.001). Phenylephrine did not change the accommodative response to a 4 D Badal target as measured by either autorefraction or photorefraction (p > 0.30). There was statistically significant thickening of the anterior region and thinning of the posterior region of the ciliary muscle with accommodation (p < 0.001, all locations). Phenylephrine did not affect either baseline ciliary muscle thickness or the accommodative contraction of the muscle (p > 0.09). Conclusions. Low-dose phenylephrine does not affect ciliary muscle dimensions, ciliary muscle contractility, or accommodative response to a 4 D near target. (Optom Vis Sci 2012; 89:1507-1511)
引用
收藏
页码:1507 / 1511
页数:5
相关论文
共 31 条
  • [1] Repeatability and validity of the PowerRefractor and the Nidek AR600-A in an adult population with healthy eyes
    Allen, PM
    Radhakrishnan, H
    O'Leary, DJ
    [J]. OPTOMETRY AND VISION SCIENCE, 2003, 80 (03) : 245 - 251
  • [2] Subjective depth-of-focus of the eye
    Atchison, DA
    Charman, WN
    Woods, RL
    [J]. OPTOMETRY AND VISION SCIENCE, 1997, 74 (07) : 511 - 520
  • [3] Comparative higher-order aberration measurement of the LADARWave and Visx WaveScan aberrometers at varying pupil sizes and after pharmacologic dilation and cycloplegia
    Awwad, ST
    El-Kateb, M
    McCulley, JP
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02) : 203 - 214
  • [4] How Should We Measure the Ciliary Muscle?
    Bailey, Melissa D.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1817 - 1818
  • [5] Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor)
    Choi, M
    Weiss, S
    Schaeffel, F
    Seidemann, A
    Howland, HC
    Wilhelm, B
    Wilhelm, H
    [J]. OPTOMETRY AND VISION SCIENCE, 2000, 77 (10) : 537 - 548
  • [6] Culhane HM, 1999, INVEST OPHTH VIS SCI, V40, P1137
  • [7] Biometric investigation of changes in the anterior eye segment during accommodation
    Drexler, W
    Baumgartner, A
    Findl, O
    Hitzenberger, CK
    Fercher, AF
    [J]. VISION RESEARCH, 1997, 37 (19) : 2789 - 2800
  • [8] The thickness of the aging human lens obtained from corrected scheimpflug images
    Dubbelman, M
    Van der Heijde, GL
    Weeber, HA
    [J]. OPTOMETRY AND VISION SCIENCE, 2001, 78 (06) : 411 - 416
  • [9] Change in shape of the aging human crystalline lens with accommodation
    Dubbelman, M
    Van der Heijde, GL
    Weeber, HA
    [J]. VISION RESEARCH, 2005, 45 (01) : 117 - 132
  • [10] Changes in the internal structure of the human crystalline lens with age and accommodation
    Dubbleman, M
    Van der Heijde, GL
    Weeber, HA
    Vrensen, GFJM
    [J]. VISION RESEARCH, 2003, 43 (22) : 2363 - 2375