Wide-band characterization of current probes

被引:36
作者
Cerri, G [1 ]
De Leo, R [1 ]
Primiani, VM [1 ]
Pennesi, S [1 ]
Russo, P [1 ]
机构
[1] Univ Ancona, Dipartimento Elettron & Automat, I-60131 Ancona, Italy
关键词
bulk current injection (BCI); current probe; time domain (TD);
D O I
10.1109/TEMC.2003.819061
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of current probes for the injection of wide-band disturbance in electromagnetic compatibility applications requires their accurate characterization up to few gigahertz. While the representation of the current probe with a simple transformer is acceptable at low frequencies, the spectral content of fast signals requires models which are accurate even at gigahertz frequencies. This can be accomplished directly by measurements in the frequency domain (FD), making use of a S-matrix representation of the probe, or in the time domain (TD), recovering the transfer functions from the impulse responses measurement. Both techniques suffer limitations due to numerical and experimental problems; in particular, the FD approach leads to the solution of an inverse problem, with numerical instabilities in the high-frequency range, whereas the TD approach is not so accurate in the low-frequency range of the sought transfer function. The paper combines the two techniques to overcome these difficulties and achieve a better accuracy across the overall bandwidth. The characterization of a commercially available current probe allows comparison of numerical results with experimental measurements.
引用
收藏
页码:616 / 625
页数:10
相关论文
共 8 条
[1]   The dimers stay intact: a quantitative photoelectron study of the adsorption system Si{100}(2x1)-C2H4 [J].
Baumgaertel, P. ;
Lindsay, R. ;
Schaff, O. ;
Giessel, T. ;
Terborg, R. ;
Hoeft, J. T. ;
Polcik, M. ;
Bradshaw, A. M. ;
Carbone, M. ;
Piancastelli, M. N. ;
Zanoni, R. ;
Toomes, R. L. ;
Woodruff, D. P. .
NEW JOURNAL OF PHYSICS, 1999, 1 :20.1-20.15
[2]  
*IEC, 2003, 6100046 IEC
[3]  
*IEC, 1995, 100044 IEC
[4]  
*ISO, 1995, 114514 ISO
[5]  
*RTCA, 1993, RTCADO160C
[6]   Calibration of current transducers at high frequencies [J].
Ruddle, AR ;
Pomeroy, SC ;
Ward, DD .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2001, 43 (01) :100-104
[7]  
SOMLO PI, 1985, MICROWAVCE IMPEDANCE
[8]   A RIGOROUS TECHNIQUE FOR MEASURING THE SCATTERING MATRIX OF A MULTIPORT DEVICE WITH A 2-PORT NETWORK ANALYZER [J].
TIPPET, JC ;
SPECIALE, RA .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1982, 30 (05) :661-666