Long-term results of transscleral cyclophotocoagulation in refractory pediatric glaucoma patients

被引:51
作者
Autrata, R [1 ]
Rehurek, J [1 ]
机构
[1] Masaryk Univ, Fac Med, Dept Pediat Ophthalmol, CZ-61300 Brno, Czech Republic
关键词
diode laser; cyclodestructive procedures; refractory pediatric glaucoma; children; refractory glaucoma;
D O I
10.1159/000073068
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We evaluated efficacy and complications of diode laser cyclophotocoagulation in pediatric patients with refractory glaucomas. The retrospective study comprised 69 eyes of 53 pediatric patients with uncontrolled refractory glaucoma treated by transscleral diode laser cyclophotocoagulation. The mean age was 6.1 +/- 4.29 (range 0.9-15) years. The main parameters evaluated were: intraocular pressure (IOP), visual acuity, and complications. The mean follow-up period was 5.6 +/- 2.8 (range 2.2-9.5) years. Treatment success was defined as a postoperative IOP of less than or equal to21 mm Hg, with or without adjunctive glaucoma medications. The baseline mean pretreatment IOP was 34.08 +/- 7.13 (range 24-47) mm Hg. The final mean postoperative IOP was 20.81 +/- 6.38 (range 12-33) mm Hg after a mean of 2.13 +/- 1.47 (range 1-6) laser procedures. After one treatment session, 66% of the eyes had a successful reduction in IOP (less than or equal to21 mm Hg), but this had fallen to 41% by 1 year. With repeat cyclophotocoagulation, 79% of the eyes had a clinically effective reduction in IOP(less than or equal to21 mm Hg) for 1 year (mean 7.1-month interval between treatments). Postoperative complications included choroidal detachment in 4 eyes and retinal detachment in 2 eyes with progression of vision loss. All these complications occurred in aphakic patients. Cyclophotocoagulation by diode laser is a useful therapy for the treatment of refractory pediatric glaucomas with uncontrolled IOP. Cyclodiode repeated treatment can provide effective control of IOP with a low risk of severe complications. Aphakic patients may have an increased risk of postoperative complications. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 30 条
[1]   Filtration procedures supplemented with mitomycin C in the management of childhood glaucoma [J].
Azuara-Blanco, A ;
Wilson, RP ;
Spaeth, GL ;
Schmidt, CM ;
Augsburger, JJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (02) :151-156
[2]   Trabeculectomy with adjunctive mitomycin C in pediatric glaucoma [J].
Beck, AD ;
Wilson, WR ;
Lynch, MG ;
Lynn, MJ ;
Noe, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (05) :648-657
[3]   TRANSSCLERAL RUBY-LASER CYCLOCOAGULATION [J].
BECKMAN, H ;
WAELTERMANN, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 98 (06) :788-795
[4]   ''Cyclodiode'' - Trans-scleral diode laser cyclophotocoagulation in the treatment of advanced refractory glaucoma [J].
Bloom, PA ;
Tsai, JC ;
Sharma, K ;
Miller, MH ;
Rice, NSC ;
Hitchings, RA ;
Khaw, PT .
OPHTHALMOLOGY, 1997, 104 (09) :1508-1519
[5]  
Bock CJ, 1997, J PEDIAT OPHTH STRAB, V34, P235
[6]   Endoscopic photocoagulation of the ciliary body for treatment of refractory glaucomas [J].
Chen, J ;
Cohn, RA ;
Lin, SC ;
Cortes, AE ;
Alvarado, JA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (06) :787-796
[7]   INITIAL CLINICAL-EXPERIENCE WITH THE AHMED GLAUCOMA VALVE IMPLANT [J].
COLEMAN, AL ;
HILL, R ;
WILSON, MR ;
CHOPLIN, N ;
KOTASNEUMANN, R ;
TAM, M ;
BACHARACH, J ;
PANEK, WC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (01) :23-31
[8]   Long-term follow-up of Molteno drains used in the treatment of glaucoma presenting in childhood [J].
Cunliffe, IA ;
Molteno, ACB .
EYE, 1998, 12 (3) :379-385
[9]  
EDWARD DP, 1989, OPHTHALMIC SURG LAS, V20, P544
[10]   Long-term effects of tube-shunt procedures on management of refractory childhood glaucoma [J].
Eid, TE ;
Katz, LJ ;
Spaeth, GL ;
Augsburger, JJ .
OPHTHALMOLOGY, 1997, 104 (06) :1011-1016