Patient-prosthesis mismatch in patients treated with transcatheter aortic valve implantation - predictors, incidence and impact on clinical efficacy. A preliminary study

被引:4
|
作者
Zbronski, Karol [1 ,2 ]
Rymuza, Bartosz [1 ,2 ]
Scislo, Piotr [1 ,2 ]
Grodecki, Kajetan [1 ,2 ]
Dobkowska, Paulina [1 ,2 ]
Wawrzacz, Marek [1 ,2 ]
Wilimski, Radoslaw [3 ]
Slowikowska, Anna [3 ]
Kochman, Janusz [1 ,2 ]
Filipiak, Krzysztof J. [1 ,2 ]
Opolski, Grzegorz [1 ,2 ]
Huczek, Zenon [1 ,2 ]
机构
[1] Med Univ Warsaw, Chair 1, Warsaw, Poland
[2] Med Univ Warsaw, Dept Cardiol, Warsaw, Poland
[3] Med Univ Warsaw, Dept Cardiac Surg, Warsaw, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2017年 / 13卷 / 04期
关键词
transcatheter aortic valve implantation; patient-prosthesis mismatch; effective orifice area; HEMODYNAMIC PERFORMANCE; STENOSIS; REPLACEMENT; SURVIVAL; OUTCOMES;
D O I
10.5114/aic.2017.71608
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Patient-prosthesis mismatch (PPM) is relatively frequent after surgical aortic valve replacement (SAVR) and negatively impacts prognosis. Aim: We sought to determine the frequency and clinical effects of PPM after transcatheter aortic valve implantation (TAVI). Material and methods: Overall, 238 patients who underwent TAVI were screened. Moderate PPM was defined as indexed effective orifice area (EOAi) between 0.65 and 0.85 cm(2)/m(2), and severe PPM as < 0.65 cm(2)/m(2). All-cause mortality and the Valve Academic Research Consortium 2 (VARC-2) defined composite of clinical efficacy at 1 year were the primary endpoints. Results: Finally, 201 patients were included (mean age: 79.6 +/- 7.4 years, 52% females). The femoral artery served as the delivery route in 79% and most of the prostheses were self-expanding (68%). Any PPM was present in 48 (24%) subjects, and only 7 (3.5%) had severe PPM. Body surface area (BSA) independently predicted any PPM (OR = 16.9, p < 0.001) whereas post-dilation tended to protect against PPM (OR = 0.46, p = 0.09). All-cause mortality was similar in patients with moderate or severe PPM as compared to those with no PPM (14.6% vs. 14.3% vs. 13.1%, respectively, log-rank p = 0.98). Neither moderate (OR = 1.6, 95% CI: 0.8-3.2, p = 0.16) nor severe PPM (OR = 1.67, 95% CI: 0.36-7.7, p = 0.51) had a significant impact on composite endpoint, or its elements, with the exception of transvalvular pressure gradient > 20 mm Hg. Conclusions: Severe PPM after TAVI is rare, can be predicted by larger BSA and does not seem to affect mid-term mortality or composite clinical outcome. Larger studies are needed to find different independent predictors of PPM and elucidate its impact in terms of device durability and long-term clinical efficacy.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 50 条
  • [41] Acute kidney injury following transcatheter aortic valve implantation: incidence, predictors and clinical outcome
    Saia, Francesco
    Ciuca, Cristina
    Taglieri, Nevio
    Marrozzini, Cinzia
    Savini, Carlo
    Bordoni, Barbara
    Dall'Ara, Gianni
    Moretti, Carolina
    Pilato, Emanuele
    Martin-Suarez, Sofia
    Petridis, Francesco Dimitri
    Di Bartolomeo, Roberto
    Branzi, Angelo
    Marzocchi, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1034 - 1040
  • [42] Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
    Astudillo, Luis M.
    Santana, Orlando
    Urbandt, Pablo A.
    Benjo, Alexandre M.
    Elkayam, Lior U.
    Nascimento, Francisco O.
    Lamas, Gervasio A.
    Lamelas, Joseph
    CLINICS, 2012, 67 (01) : 55 - 60
  • [43] Predictors and Clinical Implications of Atrial Fibrillation in Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
    Barbash, Israel M.
    Minha, Sa'ar
    Ben-Dor, Itsik
    Dvir, Danny
    Torguson, Rebecca
    Aly, Muhammad
    Bond, Elizabeth
    Satler, Lowell F.
    Pichard, Augusto D.
    Waksman, Ron
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (03) : 468 - 477
  • [44] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement in Asian Patients
    Chen, Ying-Hwa
    Chang, Hsiao-Huang
    Kuo, Chia-Cheng
    Leu, Hsin-Bang
    Lin, Su-Man
    ANNALS OF THORACIC SURGERY, 2022, 114 (05) : 1612 - 1619
  • [45] Incidence and impact of renal dysfunction on clinical outcomes after transcatheter aortic valve implantation
    Franzone, Anna
    Stortecky, Stefan
    Pilgrim, Thomas
    Asami, Masahiko
    Lanz, Jonas
    Heg, Dik
    Langhammer, Bettina
    Piccolo, Raffaele
    Lee, Joe K. T.
    Praz, Fabien
    Raeber, Lorenz
    Valgimigli, Marco
    Roost, Eva
    Windecker, Stephan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 250 : 73 - 79
  • [46] Incidence and Predictors of Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement
    Maan, Abhishek
    Refaat, Marwan M.
    Heist, Edwin Kevin
    Passeri, Jonathan
    Inglessis, Ignacio
    Ptaszek, Leon
    Vlahakes, Gus
    Ruskin, Jeremy N.
    Palacios, Igor
    Sundt, Thoralf
    Mansour, Moussa
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (07): : 878 - 886
  • [47] Incidence and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with a balloon-expandable biosprosthesis in patients with bicuspid aortic valves
    Suygun, Hakan
    Kasapkara, Haci Ahmet
    Guney, Murat Can
    Polat, Melike
    Bozkurt, Engin
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (03): : 311 - 318
  • [48] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation With the Medtronic CoreValve System in Patients With Aortic Stenosis
    Tzikas, Apostolos
    Piazza, Nicolo
    Geleijnse, Marcel L.
    Van Mieghem, Nicolas
    Nuis, Rutger-Jan
    Schultz, Carl
    van Geuns, Robert-Jan
    Galema, Tjebbe W.
    Kappetein, Arie-Pieter
    Serruys, Patrick W.
    de Jaegere, Peter P.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (02) : 255 - 260
  • [49] Atrial fibrillation in transcatheter aortic valve implantation patients: Incidence, outcome and predictors of new onset
    Zweiker, David
    Froeschl, Mario
    Tiede, Stephanie
    Weidinger, Paul
    Schmid, Johannes
    Manninger, Martin
    Brussee, Helmut
    Zweiker, Robert
    Binder, Josepha
    Maechler, Heinrich
    Marte, Wolfgang
    Maier, Robert
    Luha, Olev
    Schmidt, Albrecht
    Scherr, Daniel
    JOURNAL OF ELECTROCARDIOLOGY, 2017, 50 (04) : 402 - 409
  • [50] Impact of Patient-Prosthesis Mismatch in the Aortic Position: Twenty-Year Experience with Korean Patients
    Jeong, Dong Seop
    Chang, Hyoung Woo
    Kim, Kyung-Hwan
    Ahn, Hyuk
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (01) : 56 - 63