Exploration of different x-ray Talbot-Lau setups for dark-field lung imaging examined in a porcine lung

被引:16
作者
Ludwig, Veronika [1 ]
Seifert, Maria [1 ]
Hauke, Christian [1 ,3 ]
Hellbach, Katharina [2 ]
Horn, Florian [1 ]
Pelzer, Georg [1 ]
Radicke, Marcus [3 ]
Rieger, Jens [1 ]
Sutter, Sven-Martin [3 ]
Michel, Thilo [1 ]
Anton, Gisela [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Erlangen Ctr Astroparticle Phys, D-91058 Erlangen, Germany
[2] Ludwig Maximilians Univ Munchen, Dept Radiol, Univ Hosp, D-80336 Munich, Germany
[3] Siemens Healthcare GmbH, D-91301 Forchheim, Germany
关键词
x-ray dark-field imaging; correlation length; lung/pulmonary imaging; sensitivity and visibility; grating-based x-ray imaging; Talbot-Lau interferometer; NONDESTRUCTIVE CHARACTERIZATION; COMPUTED-TOMOGRAPHY; CONTRAST; DIAGNOSIS; RADIOGRAPHY; SENSITIVITY; SIMULATION; GENERATION; COHERENT; ORIGIN;
D O I
10.1088/1361-6560/ab051c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray dark-field imaging is a promising technique for lung diagnosis. Due to the alveolar structure of lung tissue, a higher contrast is obtained by the dark-field image compared to the attenuation image. Animal studies indicate an enhancement regarding the detection of lung diseases in early stages. In this publication, we focus on the influence of different Talbot-Lau interferometer specifications while maintaining the x-ray source, sample magnification and detector system. By imaging the same porcine lung with three different grating sets, we analyze the contrast-to-noise ratio of the obtained dark-field images with respect to visibility and correlation length. We demonstrate that relatively large grating periods of the phase and of the analyzer grating are sufficient for high quality lung imaging at reasonable dose levels.
引用
收藏
页数:13
相关论文
共 66 条
[1]  
Als-Nielsen J., 2011, Elements of Modern X-ray Physics, V2nd
[2]   BINARY PHASE GRATING FOR ARRAY GENERATION AT 1/6 OF TALBOT LENGTH [J].
ARRIZON, V ;
LOPEZOLAZAGASTI, E .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (04) :801-804
[3]   Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy [J].
Astolfo, Alberto ;
Endrizzi, Marco ;
Vittoria, Fabio A. ;
Diemoz, Paul C. ;
Price, Benjamin ;
Haig, Ian ;
Olivo, Alessandro .
SCIENTIFIC REPORTS, 2017, 7
[4]   Laboratory-based X-ray phase-imaging scanner using Talbot-Lau interferometer for non-destructive testing [J].
Bachche, Shivaji ;
Nonoguchi, Masahiro ;
Kato, Koichi ;
Kageyama, Masashi ;
Koike, Takafumi ;
Kuribayashi, Masaru ;
Momose, Atsushi .
SCIENTIFIC REPORTS, 2017, 7
[5]   In-vivo dark-field and phase-contrast x-ray imaging [J].
Bech, M. ;
Tapfer, A. ;
Velroyen, A. ;
Yaroshenko, A. ;
Pauwels, B. ;
Hostens, J. ;
Bruyndonckx, P. ;
Sasov, A. ;
Pfeiffer, F. .
SCIENTIFIC REPORTS, 2013, 3
[6]  
Biederer J, 2003, RADIOLOGY, V226
[7]   Experimental Realisation of High-sensitivity Laboratory X-ray Grating-based Phase-contrast Computed Tomography [J].
Birnbacher, Lorenz ;
Willner, Marian ;
Velroyen, Astrid ;
Marschner, Mathias ;
Hipp, Alexander ;
Meiser, Jan ;
Koch, Frieder ;
Schroeter, Tobias ;
Kunka, Danays ;
Mohr, Juergen ;
Pfeiffer, Franz ;
Herzen, Julia .
SCIENTIFIC REPORTS, 2016, 6
[8]   AN X-RAY INTERFEROMETER [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 6 (08) :155-&
[9]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[10]   Differential x-ray phase contrast imaging using a shearing interferometer [J].
David, C ;
Nöhammer, B ;
Solak, HH ;
Ziegler, E .
APPLIED PHYSICS LETTERS, 2002, 81 (17) :3287-3289