Identification and classification of components in flash pyrolysis oil and hydrodeoxygenated oils by two-dimensional gas chromatography and time-of-flight mass spectrometry

被引:95
作者
Marsman, J. H. [1 ]
Wildschut, J. [1 ]
Evers, P. [2 ]
de Koning, S. [3 ]
Heeres, H. J. [1 ]
机构
[1] Univ Groningen, Dept Chem Engn, NL-9747 AG Groningen, Netherlands
[2] CS Aspa, NL-9460 AB Gieten, Netherlands
[3] LECO Instruments, Dept Separat Sci, D-41199 Monchengladbach, Germany
关键词
comprehensive two-dimensional GC; time-of-flight TOF mass spectrometry; flash pyrolysis oil; hydrodeoxygenated HDO oil; fractionation; identification and classification of components; kinetic and catalyst study;
D O I
10.1016/j.chroma.2008.02.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrodeoxygenated pyrolysis oils (HDO) are considered promising renewable liquid energy carriers. To gain insights in the various reaction pathways taking place during the hydrodeoxygenation reaction of pyrolysis oil, two-dimensional gas chromatography with time-of-flight mass spectrometric analyses (2D-GC-TOF-MS) was applied on the feedstock and product oil. Chromatographic parameters like injection temperature and column choice of the D-1-D-2 ensemble are discussed. Fractionation of the oils by hexane extraction was applied to show the distribution of analytes over the phases. Some 1000 and 2000 components in the pyrolysis and HDO oil, respectively could be identified and classified. The TOF-MS detection considerably improved the understanding of the molecular distribution over the D-1-D-2 retention time fields in the contour plot, in order to classify the analytes in functional groups. By group-type classification of the main components (>0.3% relative area), it was possible to characterize the oils by 250 and 350 analytes, respectively pyrolysis oil and HDO oil, describing 75% of the chromatographable fraction. The 2D-GC-TOF-MS method showed to be a useful and fast technique to determine the composition of (upgraded) pyrolysis oil and is potentially a very useful tool for exploratory catalyst research and kinetic studies. The 2D-GC-TOF-MS technique is not only useful for the chemical study as such, but also provides the basic knowledge for method transfer to a 2D-GC-FID (flame ionization detector) application. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 19 条
[11]  
Polk M., 1980, Nucl. Chem. Waste Manag., V1, P111, DOI [10.1016/0191-815X(80)90005-4, DOI 10.1016/0191-815X(80)90005-4]
[12]   The conversion of chicken manure to bio-oil by fast pyrolysis. III. Analyses of chicken manure, bio-oils and char by Py-FIMS and Py-FDMS [J].
Schnitzer, Morris I. ;
Monreal, Carlos M. ;
Jandl, Gerald .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2008, 43 (01) :81-95
[13]   Characterization of biomass-based flash pyrolysis oils [J].
Sipila, K ;
Kuoppala, E ;
Fagernas, L ;
Oasmaa, A .
BIOMASS & BIOENERGY, 1998, 14 (02) :103-113
[14]   ESTIMATING PROBABILITIES OF CORRECT IDENTIFICATION FROM RESULTS OF MASS-SPECTRAL LIBRARY SEARCHES [J].
STEIN, SE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :316-323
[15]   Composition of products obtained via fast pyrolysis of olive-oil residue:: Effect of pyrolysis temperature [J].
Uzun, Basak Burcu ;
Putun, Ayse Eren ;
Putun, Ersan .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2007, 79 (1-2) :147-153
[16]   Group-type analysis of oxygenated compounds with a silica gel porous layer open tubular column and comprehensive two-dimensional supercritical fluid and gas chromatography [J].
Venter, A ;
Makgwane, PR ;
Rohwer, ER .
ANALYTICAL CHEMISTRY, 2006, 78 (06) :2051-2054
[17]  
Vreuls RJJ, 1999, J MICROCOLUMN SEP, V11, P663, DOI 10.1002/(SICI)1520-667X(199911)11:9<663::AID-MCS4>3.0.CO
[18]  
2-0
[19]   Study of hydrodeoxygenation of bio-oil from the fast pyrolysis of biomass [J].
Zhang, SP ;
Yan, YJ ;
Ren, JW ;
Li, TC .
ENERGY SOURCES, 2003, 25 (01) :57-65