Soft-Material-Based Smart Insoles for a Gait Monitoring System

被引:21
作者
Wang, Changwon [1 ]
Kim, Young [2 ]
Min, Se Dong [1 ]
机构
[1] Soonchunhyang Univ, Dept Med IT Engn, Asan 31538, South Korea
[2] Soonchunhyang Univ, Wellness Coaching Serv Res Ctr, Asan 31538, South Korea
基金
新加坡国家研究基金会;
关键词
conductive textile; capacitive pressure sensor; gait; monitoring; phase coordination index; BILATERAL COORDINATION; WALKING; SPEED;
D O I
10.3390/ma11122435
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Spatiotemporal analysis of gait pattern is meaningful in diagnosing and prognosing foot and lower extremity musculoskeletal pathologies. Wearable smart sensors enable continuous real-time monitoring of gait, during daily life, without visiting clinics and the use of costly equipment. The purpose of this study was to develop a light-weight, durable, wireless, soft-material-based smart insole (SMSI) and examine its range of feasibility for real-time gait pattern analysis. A total of fifteen healthy adults (male: 10, female: 5, age 25.1 +/- 2.64) were recruited for this study. Performance evaluation of the developed insole sensor was first executed by comparing the signal accuracy level between the SMSI and an F-scan. Gait data were simultaneously collected by two sensors for 3 min, on a treadmill, at a fixed speed. Each participant walked for four times, randomly, at the speed of 1.5 km/h (C1), 2.5 km/h (C2), 3.5 km/h (C3), and 4.5 km/h (C4). Step count from the two sensors resulted in 100% correlation in all four gait speed conditions (C1: 89 +/- 7.4, C2: 113 +/- 6.24, C3: 141 +/- 9.74, and C4: 163 +/- 7.38 steps). Stride-time was concurrently determined and R2 values showed a high correlation between the two sensors, in both feet (R-2 >= 0.90, p < 0.05). Bilateral gait coordination analysis using phase coordination index (PCI) was performed to test clinical feasibility. PCI values of the SMSI resulted in 1.75 +/- 0.80% (C1), 1.72 +/- 0.81% (C2), 1.72 +/- 0.79% (C3), and 1.73 +/- 0.80% (C4), and those of the F-scan resulted in 1.66 +/- 0.66%, 1.70 +/- 0.66%, 1.67 +/- 0.62%, and 1.70 +/- 0.62%, respectively, showing the presence of a high correlation (R-2 >= 0.94, p < 0.05). The insole developed in this study was found to have an equivalent performance to commercial sensors, and thus, can be used not only for future sensor-based monitoring device development studies but also in clinical setting for patient gait evaluations.
引用
收藏
页数:14
相关论文
共 28 条
[1]   Smart Shoe-Assisted Evaluation of Using a Single Trunk/Pocket-Worn Accelerometer to Detect Gait Phases [J].
Avvenuti, Marco ;
Carbonaro, Nicola ;
Cimino, Mario G. C. A. ;
Cola, Guglielmo ;
Tognetti, Alessandro ;
Vaglini, Gigliola .
SENSORS, 2018, 18 (11)
[2]   Gait Speed Is Not Associated with Vasogenic Shock or Cardiogenic Shock following Cardiac Surgery, but Is Associated with Increased Hospital Length of Stay [J].
Clark, Kimmie ;
Leathers, Taylor ;
Rotich, Duncan ;
He, Jianghua ;
Wirtz, Katy ;
Daon, Emmanuel ;
Flynn, Brigid C. .
CRITICAL CARE RESEARCH AND PRACTICE, 2018, 2018
[3]   The reproducibility of acquiring three dimensional gait and plantar pressure data using established protocols in participants with and without type 2 diabetes and foot ulcers [J].
Fernando, Malindu ;
Crowther, Robert G. ;
Cunningham, Margaret ;
Lazzarini, Peter A. ;
Sangla, Kunwarjit S. ;
Buttner, Petra ;
Golledge, Jonathan .
JOURNAL OF FOOT AND ANKLE RESEARCH, 2016, 9
[4]   Gait Coordination Deteriorates in Independent Old-Old Adults [J].
Gimmon, Yoav ;
Rashad, Hisham ;
Kurz, Ilan ;
Plotnik, Meir ;
Riemer, Raziel ;
Debi, Ronen ;
Shapiro, Amir ;
Melzer, Itshak .
JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2018, 26 (03) :382-389
[5]   IS WALKING A RANDOM-WALK - EVIDENCE FOR LONG-RANGE CORRELATIONS IN STRIDE INTERVAL OF HUMAN GAIT [J].
HAUSDORFF, JM ;
PENG, CK ;
LADIN, Z ;
WEI, JY ;
GOLDBERGER, AL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (01) :349-358
[6]   Assessing a novel way to measure step count while walking using a custom mobile phone application [J].
Hurt, Christopher P. ;
Lein, Donald H., Jr. ;
Smith, Christian R. ;
Curtis, Jeffrey R. ;
Westfall, Andrew O. ;
Cortis, Jonathan ;
Rice, Clayton ;
Willig, James H. .
PLOS ONE, 2018, 13 (11)
[7]  
Kibushi B., 2018, EXP BRAIN RES
[8]   Wearing the F-Scan mobile in-shoe pressure measurement system alters gait characteristics during running [J].
Kong, Pui W. ;
De Heer, Hendrik .
GAIT & POSTURE, 2009, 29 (01) :143-145
[9]  
Lemarie E.D., 2006, P 2006 INT C IEEE EN
[10]   Cognitive Involvement in Balance, Gait and Dual-Tasking in Aging: A Focused Review From a Neuroscience of Aging Perspective [J].
Li, Karen Z. H. ;
Bherer, Louis ;
Mirelman, Anat ;
Maidan, Inbal ;
Hausdorff, Jeffrey M. .
FRONTIERS IN NEUROLOGY, 2018, 9