Solid-phase extraction and simultaneous determination of trace amounts of sulphonated and azo sulphonated dyes using microemulsion-modified-zeolite and multivariate calibration

被引:63
|
作者
Al-Degs, Yahya S. [2 ]
El-Sheikh, Amjad H. [2 ]
Al-Ghouti, Mohammad A. [3 ]
Hemmateenejad, Bahram [4 ,5 ]
Walker, Gavin M. [1 ]
机构
[1] Queens Univ Belfast, Sch Chem & Chem Engn, Belfast BT9 5AG, Antrim, North Ireland
[2] Hashemite Univ, Dept Chem, Zarqa, Jordan
[3] Royal Sci Soc, Ind Chem Ctr, Amman, Jordan
[4] Shiraz Univ, Dept Chem, Shiraz, Iran
[5] Shiraz Univ Med Sci, Med & Nat Prod Chem Res Ctr, Shiraz 71345, Iran
关键词
microemulsions; solid-phase extraction; sulphonated and azo sulphonated dyes; preconcentration; natural zeolite; spectral overlap; multivariate calibration;
D O I
10.1016/j.talanta.2007.12.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid analytical method for the determination of trace levels of five sulphonated and azo sulphonated reactive dyes: Cibacron Reactive Blue 2 (C-Blue, trisulphonated dye), Cibacron Reactive Red 4 (C-Red, tetrasulphonated azo dye), Cibacron Reactive Yellow 2 (C-Yellow, trisulphonated azo dye), Levafix Brilliant Red E-4BA (L-Red, trisulphonated dye), and Levafix Brilliant Blue E-4BA (L-Blue, disulphonated dye) in water is presented. Initially, the dyes were preconcentrated from 250 ml of water samples with solid-phase extraction using natural zeolite sample previously modified with a a microemulsion. The modified zeolite exhibited an excellent extraction for the dyes from solution. The parameters that influence quantitative recovery of reactive dyes like amount of extractant, volume of dye solution, pH, ionic strength, and extraction-elution flow rate were varied and optimized. After elution of the adsorbed dyes, the concentration of dyes was determined spectrophotometrically with the aid of principle component regression (PCR) method without separation of dyes. The results obtained from PCR method were comparable to those obtained from HPLC method confirming the effectiveness of the proposed method. With the aid of SPE by M-zeolite, the concentration of dyes could be reproducibly detected over the range 25-200 ppb for C-Yellow and L-Blue and from 50 to 250 ppb for C-Blue, C-Red, and L-Red. The multivariate detection limits of dyes were found to be 15 ppb for C-Yellow and L-Blue and 25 ppb for C-Blue, C-Red, and L-Red dyes. The proposed chemometric method gave recoveries from 85.4 to 115.3% and R.S.D. from 1.0 to 14.5% for determination of the five dyes without any prior separation for solutes. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:904 / 915
页数:12
相关论文
共 50 条
  • [21] Determination of trace amounts of Se(IV) by hydride generation atomic fluorescence spectrometry after solid-phase extraction using magnetic multi-walled carbon nanotubes
    Wang, Yang
    Xie, Jing
    Wu, Yichun
    Hu, Xiaoya
    Yang, Chun
    Xu, Qin
    TALANTA, 2013, 112 : 123 - 128
  • [22] Determination of sulfonated azo dyes in groundwater and industrial effluents by automated solid-phase extraction followed by capillary electrophoresis mass spectrometry
    Riu, J
    Schönsee, I
    Barceló, D
    JOURNAL OF MASS SPECTROMETRY, 1998, 33 (07): : 653 - 663
  • [23] Determination of trace metals in drinking water using solid-phase extraction disks and X-ray fluorescence spectrometry
    Hou, XD
    Peters, HL
    Yang, Z
    Wagner, KA
    Batchelor, JD
    Daniel, MM
    Jones, BT
    APPLIED SPECTROSCOPY, 2003, 57 (03) : 338 - 342
  • [24] Selective solid-phase extraction of trace mercury(II) using a silica gel modified with diethylenetriamine and thiourea
    Yin Jiang
    Huatang Zhang
    Qun He
    Zheng Hu
    Xijun Chang
    Microchimica Acta, 2012, 178 : 421 - 428
  • [25] Solid-phase extraction using multiwalled carbon nanotubes and quinalizarin for preconcentration and determination of trace amounts of some heavy metals in food, water and environmental samples
    Gouda, Ayman A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (12) : 1210 - 1222
  • [26] Determination of trace level microcystins in water using solid-phase extraction and high performance liquid chromatography
    Zhang, WH
    Xu, XQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (05) : 522 - 525
  • [27] Determination of Trace Elements in High Purity Tungsten Using Solid-Phase Extraction/ICP-MS
    Hasegawa, Shin-ichi
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2009, 73 (01) : 15 - 18
  • [28] Solid phase extraction of trace amounts of Pb(II) in opium, heroin, lipstick, plants and water samples using modified magnetite nanoparticles prior to its atomic absorption determination
    Karimi, Mohammad Ali
    Hatefi-Mehrjardi, Abdolhamid
    Mohammadi, Sayed Zia
    Mohadesi, Alireza
    Mazloum-Ardakani, Mohammad
    Nezhad, Mohammad Reza Hormozi
    Kabir, Asghar Askarpour
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2012, 9 (02) : 171 - 180
  • [29] Graphene-based solid-phase extraction combined with flame atomic absorption spectrometry for a sensitive determination of trace amounts of lead in environmental water and vegetable samples
    Wang, Yukun
    Gao, Shutao
    Zang, Xiaohuan
    Li, Jingci
    Ma, Jingjun
    ANALYTICA CHIMICA ACTA, 2012, 716 : 112 - 118
  • [30] Determination of Copper in Water Samples after Solid-phase Extraction Using Dimethylglyoxime-modified Silica
    Anilan, Burcu
    Gedikbey, Tevfik
    Akar, Sibel Tunali
    CLEAN-SOIL AIR WATER, 2010, 38 (04) : 344 - 352