Solid-phase extraction and simultaneous determination of trace amounts of sulphonated and azo sulphonated dyes using microemulsion-modified-zeolite and multivariate calibration

被引:63
|
作者
Al-Degs, Yahya S. [2 ]
El-Sheikh, Amjad H. [2 ]
Al-Ghouti, Mohammad A. [3 ]
Hemmateenejad, Bahram [4 ,5 ]
Walker, Gavin M. [1 ]
机构
[1] Queens Univ Belfast, Sch Chem & Chem Engn, Belfast BT9 5AG, Antrim, North Ireland
[2] Hashemite Univ, Dept Chem, Zarqa, Jordan
[3] Royal Sci Soc, Ind Chem Ctr, Amman, Jordan
[4] Shiraz Univ, Dept Chem, Shiraz, Iran
[5] Shiraz Univ Med Sci, Med & Nat Prod Chem Res Ctr, Shiraz 71345, Iran
关键词
microemulsions; solid-phase extraction; sulphonated and azo sulphonated dyes; preconcentration; natural zeolite; spectral overlap; multivariate calibration;
D O I
10.1016/j.talanta.2007.12.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid analytical method for the determination of trace levels of five sulphonated and azo sulphonated reactive dyes: Cibacron Reactive Blue 2 (C-Blue, trisulphonated dye), Cibacron Reactive Red 4 (C-Red, tetrasulphonated azo dye), Cibacron Reactive Yellow 2 (C-Yellow, trisulphonated azo dye), Levafix Brilliant Red E-4BA (L-Red, trisulphonated dye), and Levafix Brilliant Blue E-4BA (L-Blue, disulphonated dye) in water is presented. Initially, the dyes were preconcentrated from 250 ml of water samples with solid-phase extraction using natural zeolite sample previously modified with a a microemulsion. The modified zeolite exhibited an excellent extraction for the dyes from solution. The parameters that influence quantitative recovery of reactive dyes like amount of extractant, volume of dye solution, pH, ionic strength, and extraction-elution flow rate were varied and optimized. After elution of the adsorbed dyes, the concentration of dyes was determined spectrophotometrically with the aid of principle component regression (PCR) method without separation of dyes. The results obtained from PCR method were comparable to those obtained from HPLC method confirming the effectiveness of the proposed method. With the aid of SPE by M-zeolite, the concentration of dyes could be reproducibly detected over the range 25-200 ppb for C-Yellow and L-Blue and from 50 to 250 ppb for C-Blue, C-Red, and L-Red. The multivariate detection limits of dyes were found to be 15 ppb for C-Yellow and L-Blue and 25 ppb for C-Blue, C-Red, and L-Red dyes. The proposed chemometric method gave recoveries from 85.4 to 115.3% and R.S.D. from 1.0 to 14.5% for determination of the five dyes without any prior separation for solutes. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:904 / 915
页数:12
相关论文
共 50 条
  • [11] A solid-phase extraction method using acid-modified Transcarpathian clinoptilolite for preconcentration of trace amounts of lead in water samples
    Volodymyr O. Vasylechko
    Galyna V. Gryshchouk
    Mariya I. Kaminska
    Bogdan M. Stel’makhovych
    Applied Nanoscience, 2019, 9 : 1057 - 1065
  • [12] Selective solid-phase extraction of trace mercury(II) using a silica gel modified with diethylenetriamine and thiourea
    Jiang, Yin
    Zhang, Huatang
    He, Qun
    Hu, Zheng
    Chang, Xijun
    MICROCHIMICA ACTA, 2012, 178 (3-4) : 421 - 428
  • [13] Agarose Based Magnetic Solid-Phase Extraction-Magnetic Field Agitation for Determination of Trace Amounts of Molybdenum in Beans
    Poursheikhi, Narges
    Hashemi, Payman
    Safdarian, Mehdi
    Serenjeh, Fariba Nazari
    Hesami, Faezeh
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (04) : 670 - 676
  • [14] Application of Deep Eutectic Solvent Modified Cotton as a Sorbent for Online Solid-Phase Extraction and Determination of Trace Amounts of Copper and Nickel in Water and Biological Samples
    Karimi, Mehdi
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2017, 176 (01) : 207 - 215
  • [15] Simultaneous spectrophotometric determination and column solid-phase extraction of two Lanaset textile dyes in environmental water samples
    Bisgin, Abdullah Taner
    Surme, Yavuz
    Ucan, Mustafa
    Narin, Ibrahim
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2016, 38 : 186 - 192
  • [16] Amberlite IR-120 Modified with 8-Hydroxyquinoline as Efficient Adsorbent for Solid-Phase Extraction and Flame Atomic Absorption Determination of Trace Amounts of Some Metal Ions
    Daneshfar, Ali
    Ghaedi, M.
    Vafafard, S.
    Shiri, L.
    Sahrai, R.
    Soylak, M.
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2012, 145 (02) : 240 - 247
  • [17] Amberlite IR-120 Modified with 8-Hydroxyquinoline as Efficient Adsorbent for Solid-Phase Extraction and Flame Atomic Absorption Determination of Trace Amounts of Some Metal Ions
    Ali Daneshfar
    M. Ghaedi
    S. Vafafard
    L. Shiri
    R. Sahrai
    M. Soylak
    Biological Trace Element Research, 2012, 145 : 240 - 247
  • [18] Magnetic solid-phase extraction to preconcentrate trace amounts of gold (III) using nickel ferrite magnetic nanoparticles
    Khoshhesab, Zahra Monsef
    Najafi, Narjes
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (13) : 1237 - 1252
  • [19] Determination of Trace Elements in Meat and Fish Samples by MIP OES Using Solid-Phase Extraction
    de Sa, Ivero Pita
    Higuera, Julymar Marcano
    Costa, Vinicius Camara
    Costa, Jose Arnaldo Santana
    da Silva, Caio Marcio Paranhos
    Nogueira, Ana Rita Araujo
    FOOD ANALYTICAL METHODS, 2020, 13 (01) : 238 - 248
  • [20] Mixed hemimicelle solid-phase extraction based on magnetic halloysite nanotubes and ionic liquids for the determination and extraction of azo dyes in environmental water samples
    Liu, Wei
    Fizir, Meriem
    Hu, Fan
    Li, Ang
    Hui, Xuanhong
    Zha, Jun
    He, Hua
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1551 : 10 - 20