Spine Stereotactic Body Radiotherapy Utilizing Cone-Beam CT Image-Guidance With a Robotic Couch: Intrafraction Motion Analysis Accounting for all Six Degrees of Freedom

被引:112
作者
Hyde, Derek [1 ,2 ]
Lochray, Fiona [1 ]
Korol, Renee [1 ]
Davidson, Melanie [1 ]
Wong, C. Shun [1 ]
Ma, Lijun [3 ]
Sahgal, Arjun [1 ,4 ]
机构
[1] Univ Toronto, Dept Radiat Oncol, Sunnybrook Hlth Sci Ctr, Toronto, ON M4M 3M5, Canada
[2] British Columbia Canc Agcy, Sindi Hawkins Canc Ctr So Interior, Kelowna, BC, Canada
[3] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[4] Univ Toronto, Princess Margaret Hosp, Dept Radiat Oncol, Toronto, ON M4M 3M5, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 82卷 / 03期
关键词
Stereotactic body radiotherapy; Cone-beam CT; Image-guided radiotherapy; Intrafraction motion; Spine radiosurgery; RADIOSURGERY; METASTASES; PRECISION; ACCURACY; ERRORS; TUMORS; IGRT;
D O I
10.1016/j.ijrobp.2011.06.1980
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the residual setup error and intrafraction motion following kilovoltage cone-beam CT (CBCT) image guidance, for immobilized spine stereotactic body radiotherapy (SBRT) patients, with positioning corrected for in all six degrees of freedom. Methods and Materials: Analysis is based on 42 consecutive patients (48 thoracic and/or lumbar metastases) treated with a total of 106 fractions and 307 image registrations. Following initial setup, a CBCT was acquired for patient alignment and a pretreatment CBCT taken to verify shifts and determine the residual setup error, followed by a midtreatment and posttreatment CBCT image. For 13 single-fraction SBRT patients, two midtreatment CBCT images were obtained. Initially, a 1.5-mm and 1 degrees tolerance was used to reposition the patient following couch shifts which was subsequently reduced to 1 mm and 1 degrees degree after the first 10 patients. Results: Small positioning errors after the initial CBCT setup were observed, with 90% occurring within 1 mm and 97% within 1 degrees. In analyzing the impact of the time interval for verification imaging (10 +/- 3 min) and subsequent image acquisitions (17 +/- 4 min), the residual setup error was not significantly different (p > 0.05). A significant difference (p = 0.04) in the average three-dimensional intrafraction positional deviations favoring a more strict tolerance in translation (1 mm vs. 1.5 mm) was observed. The absolute intrafraction motion averaged over all patients and all directions along x, y, and z axis (+/- SD) were 0.7 +/- 0.5 mm and 0.5 +/- 0.4 mm for the 1.5 mm and 1 mm tolerance, respectively. Based on a 1-mm and 1 degrees correction threshold, the target was localized to within 1.2 mm and 0.9 degrees with 95% confidence. Conclusion: Near-rigid body immobilization, intrafraction CBCT imaging approximately every 15-20 min, and strict repositioning thresholds in six degrees of freedom yields minimal intrafraction motion allowing for safe spine SBRT delivery. (C) 2012 Elsevier Inc.
引用
收藏
页码:E555 / E562
页数:8
相关论文
共 25 条
[1]   Image-guided radiosurgery for spinal tumors: methods, accuracy and patient intrafraction motion [J].
Agazaryan, Nzhde ;
Tenn, Steve E. ;
Desalles, Antonio A. F. ;
Selch, Michael T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06) :1715-1727
[2]   Evaluation of thoracic spinal cord motion using dynamic MRI [J].
Cai, Jing ;
Sheng, Ke ;
Sheehan, Jason P. ;
Benedict, Stanley H. ;
Larner, James M. ;
Read, Paul W. .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (03) :279-282
[3]   Phase I clinical evaluation of near-simultaneous computed tomographic image-guided stereotactic body radiotherapy for spinal metastases [J].
Chang, EL ;
Shiu, AS ;
Lii, MF ;
Rhines, LD ;
Mendel, E ;
Mahajan, A ;
Weinberg, JS ;
Mathews, LA ;
Brown, BW ;
Maor, MH ;
Cox, JD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05) :1288-1294
[4]   Phase I/II study of stereotactic body radiotherapy for spinal metastasis and its pattern of failure [J].
Chang, Eric L. ;
Shiu, Almon S. ;
Mendel, Ehud ;
Mathews, Leni A. ;
Mahajan, Anita ;
Allen, Pamela K. ;
Weinberg, Jeffrey S. ;
Brown, Barry W. ;
Wang, Xin Shelly ;
Woo, Shiao Y. ;
Cleeland, Charles ;
Maor, Moshe H. ;
Rhines, Laurence D. .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (02) :151-160
[5]   Effects of residual target motion for image-tracked spine radiosurgery [J].
Chuang, Cynthia ;
Sahgal, Arjun ;
Lee, Letitia ;
Larson, David ;
Huang, Kim ;
Petti, Paula ;
Verhey, Lynn ;
Ma, Lijun .
MEDICAL PHYSICS, 2007, 34 (11) :4484-4490
[6]   Technique for stereotactic body radiotherapy for spinal metastases [J].
Foote, Matthew ;
Letourneau, Daniel ;
Hyde, Derek ;
Massicotte, Eric ;
Rampersaud, Raja ;
Fehlings, Michael ;
Fisher, Charles ;
Lewis, Stephen ;
La Macchia, Nancy ;
Yu, Eugene ;
Laperriere, Normand J. ;
Sahgal, Arjun .
JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (02) :276-279
[7]   Setup accuracy of spine radiosurgery using cone beam computed tomography image guidance in patients with spinal implants Clinical article [J].
Gerszten, Peter C. ;
Monaco, Edward A., III ;
Quader, Mubina ;
Novotny, Josef, Jr. ;
Kim, Jong Oh ;
Flickinger, John C. ;
Huq, M. Saiful .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (04) :413-420
[8]   Magnitude and clinical relevance of translational and rotational patient setup errors: A cone-beam CT study [J].
Guckenberger, M ;
Meyer, J ;
Vordermark, D ;
Baier, K ;
Wilbert, J ;
Flentje, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03) :934-942
[9]   Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT) [J].
Guckenberger, Matthias ;
Meyer, Juergen ;
Wilbert, Juergen ;
Baier, Kurt ;
Bratengeier, Klaus ;
Vordermark, Dirk ;
Flentje, Michael .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (01) :56-63
[10]  
Guckenberger M, 2007, STRAHLENTHER ONKOL, V183, P307, DOI 10.1007/s00066-007-1695-0