Enhanced light collection in fluorescence microscopy using self-assembled micro-reflectors

被引:13
作者
Goeroecs, Zoltan [1 ]
McLeod, Euan [1 ]
Ozcan, Aydogan [1 ,2 ,3 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Calif NanoSyst Inst CNSI, Los Angeles, CA 90095 USA
来源
SCIENTIFIC REPORTS | 2015年 / 5卷
基金
美国国家科学基金会;
关键词
SURFACE-ROUGHNESS; QUANTUM DOTS; EMISSION;
D O I
10.1038/srep10999
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In fluorescence microscopy, the signal-to-noise ratio (SNR) of the optical system is directly linked to the numerical aperture (NA) of the microscope objective, which creates detection challenges for low-NA, wide-field and high-throughput imaging systems. Here we demonstrate a method to increase the light collection efficiency from micron-scale fluorescent objects using self-assembled vapor-condensed polyethylene glycol droplets, which act as micro-reflectors for fluorescent light. Around each fluorescent particle, a liquid meniscus is formed that increases the excitation efficiency and redirects part of the laterally-emitted fluorescent light towards the detector due to internal reflections at the liquid-air interface of the meniscus. The three-dimensional shape of this microreflector can be tuned as a function of time, vapor temperature, and substrate contact angle, providing us optimized SNR performance for fluorescent detection. Based on these self-assembled micro-reflectors, we experimentally demonstrate similar to 2.5-3 fold enhancement of the fluorescent signal from 2-10 mu m sized particles. A theoretical explanation of the formation rate and shapes of these micro-reflectors is presented, along with a ray tracing model of their optical performance. This method can be used as a sample preparation technique for consumer electronics-based microscopy and sensing tools, thus increasing the sensitivity of low-NA systems that image fluorescent microobjects.
引用
收藏
页数:10
相关论文
共 39 条
[1]   Fluorescence Enhancement at Docking Sites of DNA-Directed Self-Assembled Nanoantennas [J].
Acuna, G. P. ;
Moeller, F. M. ;
Holzmeister, P. ;
Beater, S. ;
Lalkens, B. ;
Tinnefeld, P. .
SCIENCE, 2012, 338 (6106) :506-510
[2]  
[Anonymous], 2004, ENG DAT BOOK FPS VER
[3]   Imaging intracellular fluorescent proteins at nanometer resolution [J].
Betzig, Eric ;
Patterson, George H. ;
Sougrat, Rachid ;
Lindwasser, O. Wolf ;
Olenych, Scott ;
Bonifacino, Juan S. ;
Davidson, Michael W. ;
Lippincott-Schwartz, Jennifer ;
Hess, Harald F. .
SCIENCE, 2006, 313 (5793) :1642-1645
[4]   Direct measurement of retarded van der Waals attraction [J].
Bevan, MA ;
Prieve, DC .
LANGMUIR, 1999, 15 (23) :7925-7936
[5]   Mobile Phone Based Clinical Microscopy for Global Health Applications [J].
Breslauer, David N. ;
Maamari, Robi N. ;
Switz, Neil A. ;
Lam, Wilbur A. ;
Fletcher, Daniel A. .
PLOS ONE, 2009, 4 (07)
[6]   A self-assembled microlensing rotational probe [J].
Brody, JP ;
Quake, SR .
APPLIED PHYSICS LETTERS, 1999, 74 (01) :144-146
[7]  
CASPERSSON T, 1970, CHROMOSOMA, V30, P215
[8]   Nanostructured Surfaces and Detection Instrumentation for Photonic Crystal Enhanced Fluorescence [J].
Chaudhery, Vikram ;
George, Sherine ;
Lu, Meng ;
Pokhriyal, Anusha ;
Cunningham, Brian T. .
SENSORS, 2013, 13 (05) :5561-5584
[9]   THE ROLE OF SURFACE-ROUGHNESS AND CONTACT DEFORMATION ON THE HYDRODYNAMIC DETACHMENT OF PARTICLES FROM SURFACES [J].
DAS, SK ;
SCHECHTER, RS ;
SHARMA, MM .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1994, 164 (01) :63-77
[10]  
de Gennes P.-G., 2013, Capillarity and Wetting Phenomena: Drops, Bubbles, Pearls, Waves, DOI DOI 10.1007/978-0-387-21656-0