Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

被引:4
|
作者
Kim, Seok-Gyu [1 ]
Chung, Chae-Heon [2 ]
Son, Mee-Kyoung [2 ]
机构
[1] Sungkyunkwan Univ, Coll Med, Samsung Med Ctr, Dept Prosthodont, Seoul, South Korea
[2] Chosun Univ, Coll Dent, Dept Prosthodont, Gwangju 501825, South Korea
关键词
Implant-supported dental prosthesis; Torque; Dental cement; FINITE-ELEMENT-ANALYSIS; FIXED PARTIAL DENTURES; IN-VITRO; OSSEOINTEGRATED IMPLANTS; JOINT STABILITY; PASSIVE FIT; CROWNS; PROSTHODONTICS; TORQUE; RETRIEVABILITY;
D O I
10.4047/jap.2015.7.3.207
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and non-cemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 29 条
  • [21] Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review
    Chaar, M. S.
    Att, W.
    Strub, J. R.
    JOURNAL OF ORAL REHABILITATION, 2011, 38 (09) : 697 - 711
  • [22] In Vitro Impact Testing to Simulate Implant-Supported Prosthesis Retrievability in Clinical Practice: Influence of Cement and Abutment Geometry
    Lugas, Andrea T.
    Terzini, Mara
    Zanetti, Elisabetta M.
    Schierano, Gianmario
    Manzella, Carlo
    Baldi, Domenico
    Bignardi, Cristina
    Audenino, Alberto L.
    MATERIALS, 2020, 13 (07)
  • [23] The effect of aging on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restorations
    Sahebi, Safoora
    Giti, Rashin
    Sherafati, Arian
    PLOS ONE, 2022, 17 (06):
  • [24] Comparing loosening between cement retained and screw retained implant supported crowns: a dynamic non-linear finite element analysis
    Pournasrollah, Alireza
    Negandari, Ramin
    Torab, Ali
    Faridi, Soma
    EURASIAN CHEMICAL COMMUNICATIONS, 2021, 3 (04): : 264 - 277
  • [25] Evaluation of cement-retained versus screw-retained implant-supported restorations for marginal bone loss: A systematic review and meta-analysis
    Araujo Lemos, Cleidiel Aparecido
    de Souza Batista, Victor Eduardo
    de Faria Almeida, Daniel Augusto
    Santiago Junior, Joel Ferreira
    Verri, Fellippo Ramos
    Pellizzer, Eduardo Piza
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (04) : 419 - 427
  • [26] RETENTIVE STRENGTH OF CEMENT-RETAINED IMPLANT-SUPPORTED FIXED DENTAL PROSTHESES ACCORDING TO DIFFERENT CEMENT TYPES AND CEMENTATION PROTOCOLS: AN IN VITRO ST
    Kim, Gi Youn
    Choi, Ha Eun
    Ka, You-Jung
    Moon, Hong Seok
    Oh, Kyung Chul
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (04)
  • [27] Clinical Performance of Screw-Versus Cement-Retained Fixed Implant-Supported Reconstructions-A Systematic Review
    Wittneben, Julia-Gabriela
    Millen, Christopher
    Braegger, Urs
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 84 - 98
  • [28] Effect of different implant angulations on the biomechanical performance of prosthetic screws in two implant-supported, screw-retained prostheses: A numerical and experimental study
    Chen, Jianyu
    Guo, Jiaer
    Yang, Lijia
    Wang, Lin
    Zhang, Xiao
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02) : 240.e1 - 240.e10
  • [29] Comparison of conventional and digital workflows for implant-supported screw-retained zirconia FPD bars: Fit and cement gap evaluation using SEM analysis
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Jacobs, Reinhilde
    Malinauskas, Mangirdas
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (02) : 199 - 210