Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

被引:4
|
作者
Kim, Seok-Gyu [1 ]
Chung, Chae-Heon [2 ]
Son, Mee-Kyoung [2 ]
机构
[1] Sungkyunkwan Univ, Coll Med, Samsung Med Ctr, Dept Prosthodont, Seoul, South Korea
[2] Chosun Univ, Coll Dent, Dept Prosthodont, Gwangju 501825, South Korea
关键词
Implant-supported dental prosthesis; Torque; Dental cement; FINITE-ELEMENT-ANALYSIS; FIXED PARTIAL DENTURES; IN-VITRO; OSSEOINTEGRATED IMPLANTS; JOINT STABILITY; PASSIVE FIT; CROWNS; PROSTHODONTICS; TORQUE; RETRIEVABILITY;
D O I
10.4047/jap.2015.7.3.207
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and non-cemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 29 条
  • [1] Effect of various fixation parameters on strain development of screw- and cement-retained implant-supported restorations
    Schittenhelm, Birgit
    Karl, Matthias
    Graef, Friedrich
    Heckmann, Siegfried
    Taylor, Thomas
    QUINTESSENCE INTERNATIONAL, 2013, 44 (06): : 421 - 428
  • [2] Screw retained vs. cement retained implant-supported fixed dental prosthesis
    Wittneben, Julia-Gabriela
    Joda, Tim
    Weber, Hans-Peter
    Bragger, Urs
    PERIODONTOLOGY 2000, 2017, 73 (01) : 141 - 151
  • [3] A Systematic Review of Screw- versus Cement-Retained Implant-Supported Fixed Restorations
    Sherif, Sami
    Susarla, Harlyn K.
    Kapos, Theodoros
    Munoz, Deborah
    Chang, Brian M.
    Wright, Robert F.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (01): : 1 - 9
  • [4] Abutment Screw Loosening in Single Implant Restorations: Evaluation of Fracture Strength of Implant-Supported Cement- Retained Monolithic Zirconia Restorations Repaired with Porcelain and Composite Resin
    Asli, Hamid Neshandar
    Falahchai, Mehran
    Rahimabadi, Samiye
    Arbab, Hamidreza
    Mehr, Zoheir Mousavi
    DENTAL HYPOTHESES, 2021, 12 (03): : 128 - 131
  • [5] Retrospective analysis of loosening of cement-retained vs screw-retained fixed implant-supported reconstructions
    Korsch, Michael
    Walther, Winfried
    QUINTESSENCE INTERNATIONAL, 2015, 46 (07): : 583 - 589
  • [6] BIOMECHANICAL EVALUATION OF SCREW- AND CEMENT-RETAINED IMPLANT-SUPPORTED PROSTHESES: A NONLINEAR FINITE ELEMENT ANALYSIS
    Silva, Guilherme Carvalho
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Bueno, Audrey Cristina
    Moreira, Allyson Nogueira
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06) : 1479 - 1488
  • [7] Effectiveness of Sealing Gel on Vertical Misfit at the Implant-Abutment Interface and Preload Maintenance of Screw- Retained Implant-Supported Prostheses
    Seloto, Camila Berbel
    Strazzi-Sahyon, Henrico Badaoui
    dos Santos, Paulo Henrique
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (03) : 479 - 484
  • [8] Cement- and screw-retained implant-supported prostheses: Up to 10 years of follow-up of a new design
    Preiskel, HW
    Tsolka, P
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (01) : 87 - 91
  • [9] Effects of Screw- and Cement-Retained Implant-Supported Prostheses on Bone: A Nonlinear 3-D Finite Element Analysis
    Silva, Guilherme Carvalho
    de Andrade, Guilherme Martins
    Pinto Coelho, Rodrigo Carvalho
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Moreira, Allyson Nogueira
    IMPLANT DENTISTRY, 2015, 24 (04) : 464 - 471
  • [10] Dimensional accuracy and retentive strength of a retrievable cement-retained implant-supported prosthesis
    Randi, AP
    Hsu, AT
    Verga, A
    Kim, JJ
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2001, 16 (04) : 547 - 556