Computer-based collection of mammographic exposure data for quality assurance and dosimetry

被引:9
|
作者
Rosenberg, RD
Kelsey, CA
Williamson, MR
Houston, JD
Hunt, WC
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Radiol, Albuquerque, NM 87131 USA
[2] Univ New Mexico, Hlth Sci Ctr, New Mexico Tumor Registry, Albuquerque, NM 87131 USA
关键词
mammography; dosimetry; quality assurance;
D O I
10.1118/1.1386425
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: There is potentially more. to quality assurance in mammography than the MQSA mandated tests. In this paper we describe a method of capturing individual mammogram technical parameters and the creation of new measures. These include the numbers of images required for each screening examination by technologist, median compression by technologist, and the radiation dose of the examination to the general population of patients. METHOD/MATERIALS: With this method we describe a semiautomated method of the collection of technical data from mammography exposures. The data that are automatically created by the mammography unit are saved on a computer for later analysis. The method was used on 2738 consecutive screening mammography examinations and 13621 exposures from one machine. Data were obtained from November 1998 through December 1999. RESULTS: Using standard methods, the mean glandular dose (MGD) per exposure was 2.62 mGy (SD 1.2). The mean dose per bilateral screening examination was 6.53 mGy (SD 3.07), the median dose was 6.11 mGy, and the dose range was 1.13-34.23 mGy. Rhodium filtration was used for 18% of the exposures. The average and median breast thickness was 4.9 cm. The ACR phantom MGD for this machine was 2.44 mGy at 25 kVp, and 1.97 mGy at 26 kVp. The mean number of exposures for a bilateral mammogram was 4.9, and varied by a technologist from 4.7 to 5.2. The mean compression pressure varied by technologist from 13 to 30 lbs (58-134 N). CONCLUSIONS: The mean dose per mammogram is slightly greater than the ACR phantom dose at 25 kVp. Almost five exposures were necessary for a standard bilateral examination, and this varied by technologist. The compression used also varied by technologist. The semiautomated collection of technical data can aid in maintaining an effective mammography QA program. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1546 / 1551
页数:6
相关论文
共 50 条
  • [1] Computer based collection of mammographic exposure data for quality assurance
    Rosenberg, RD
    Kelsey, CA
    Williamson, MR
    Houston, JD
    RADIOLOGY, 2000, 217 : 347 - 347
  • [2] QUALITY ASSURANCE AND COMPUTER-BASED PATIENT RECORDS
    BARNETT, GO
    WINICKOFF, RN
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (05) : 527 - 528
  • [3] Development and quality assurance of computer-based assessment batteries
    Schlegel, Robert E.
    Gilliland, Kirby
    ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2007, 22 (01) : S49 - S61
  • [4] THE USE OF A COMPUTER-BASED DATA SYSTEM FOR PERINATAL DATA-COLLECTION
    MOLLER, U
    MICHELS, W
    SEEWALD, HJ
    GROSS, W
    ZENTRALBLATT FUR GYNAKOLOGIE, 1988, 110 (08): : 509 - 515
  • [5] Subjective and computer-based characterisation of mammographic patterns
    Marias, K
    Petroudi, S
    English, R
    Adams, R
    Brady, M
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 552 - 556
  • [6] Computer-based detection and prompting of mammographic abnormalities
    Astley, SM
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 : S194 - S200
  • [7] A COMPUTER-BASED AVAILABILITY ASSURANCE PROGRAM
    GAINEN, L
    MEYER, K
    PROCEEDINGS ANNUAL RELIABILITY AND MAINTAINABILITY SYMPOSIUM, 1984, (NSYM): : 334 - 339
  • [8] IMPLEMENTATION OF A COMPUTER-BASED DATA-COLLECTION AND ANALYSIS SYSTEM
    WHITE, MJ
    RADIO AND ELECTRONIC ENGINEER, 1984, 54 (06): : 263 - 266
  • [9] COMPUTER-BASED VIDEOTAPE ANALYSIS OF TRAUMA RESUSCITATIONS FOR QUALITY ASSURANCE AND CLINICAL RESEARCH
    MANN, FA
    WALKUP, RK
    BERRYMAN, CR
    BESSEY, PQ
    WILSON, AJ
    VANNIER, MW
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 36 (02): : 226 - 230
  • [10] PERSONAL COMPUTER-BASED EXPERT-SYSTEM FOR QUALITY ASSURANCE OF ANTIMICROBIAL THERAPY
    MORRELL, R
    WASILAUSKAS, B
    WINSLOW, R
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (10): : 2067 - 2073