Development and investigation of a loop heat pipe at a high concentration of heat load

被引:16
作者
Chernysheva, M. A. [1 ]
Vershinin, S. V. [1 ]
Maydanik, Y. F. [1 ]
机构
[1] Inst Thermal Phys, Ural Branch Russian Acad Sci, Ekaterinburg, Russia
关键词
Loop heat pipe; Evaporator; Cooling of microelectronic components; High heat flux; THERMAL MANAGEMENT; FLAT EVAPORATOR;
D O I
10.1016/j.ijheatmasstransfer.2022.123316
中图分类号
O414.1 [热力学];
学科分类号
摘要
The problem of cooling small objects with extremely high heat fluxes, such as components of modern electronics and computer equipment, is solved. A copper-water loop heat pipe (LHP) is considered as an effective device for removing the heat they produce to a remote heat sink. The LHP with an effective heat transfer length of 360 mm was equipped with a flat-oval evaporator measuring 7 mm x 42 mm x 80 mm with an active zone of 32 mm x 40 mm. Experimental studies were conducted with three different -sized heat sources. Their thermal contact surface areas were 0.25 cm(2), 0.9 cm(2), and 9.0 cm(2), respectively. In experiments, the highest value of the heat flux related to the area of 0.25 cm(2) was 960 W/cm(2). To intensify heat exchange processes in the evaporator, copper heat spreaders with a thermal contact surface of 30 mm x 30 mm and various thicknesses of 1, 2 and 3 mm were used. It has been demonstrated that heat spreaders can reduce the temperature of a heat source. The greatest decrease in temperature was observed at a heat source with a heating surface of 0.25 cm(2). Numerical simulation of the temperature field of the evaporator with spreaders of different thicknesses was performed, which showed that the temperature decrease is achieved by a more efficient distribution of heat flows in the active zone of the evaporator. (C) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 29 条
[1]  
Anderson D., 1990, COMPUTATIONAL FLUID, V2
[2]   Effect of liquid filtration in a wick on thermal processes in a flat disk-shaped evaporator of a loop heat pipe [J].
Chernysheva, M. A. ;
Maydanik, Yu. F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 106 :222-231
[3]   Copper-water loop heat pipes for energy-efficient cooling systems of supercomputers [J].
Chernysheva, M. A. ;
Yushakova, S. I. ;
Maydanik, Yu. F. .
ENERGY, 2014, 69 :534-542
[4]   Simulation of thermal processes in a flat evaporator of a copper-water loop heat pipe under uniform and concentrated heating [J].
Chernysheva, Mariya A. ;
Maydanik, Yury F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) :7385-7397
[5]   Analysis of non-uniform heat loads on evaporators with loop heat pipes [J].
Fang, Tao ;
Ming, Tingzhen ;
Tso, C. P. ;
Huang, Xiaoming ;
Liu, Wei .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 75 :313-326
[6]   New evaporator structure for micro loop heat pipes [J].
Fukushima, Kazuki ;
Nagano, Hosei .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 106 :1327-1334
[7]   Study of heat dissipation characteristics of loop heat pipe with heat sink of composite material [J].
Han, Chaoling ;
He, Lidan ;
Tian, Zhizheng ;
Xu, Bo ;
Chen, Zhenqian .
APPLIED THERMAL ENGINEERING, 2022, 200
[8]   A Review on efficient thermal management of air- and liquid-cooled data centers: From chip to the cooling system [J].
Khalaj, Ali Habibi ;
Halgamuge, Saman K. .
APPLIED ENERGY, 2017, 205 :1165-1188
[9]   Cooling of server electronics: A design review of existing technology [J].
Kheirabadi, Ali C. ;
Groulx, Dominic .
APPLIED THERMAL ENGINEERING, 2016, 105 :622-638
[10]  
Ku J., 1999, SAE Trans., P503, DOI [10.4271/1999-01-2007, DOI 10.4271/1999-01-2007]