EFFECT OF BREAST VOLUME ON TREATMENT REPRODUCIBILITY ON A TOMOTHERAPY UNIT IN THE TREATMENT OF BREAST CANCER

被引:15
作者
Offerman, Shannon [1 ]
Lamba, Michael [1 ]
Lavigne, Ruth [1 ]
机构
[1] Univ Cincinnati, Dept Radiat Oncol, Cincinnati, OH 45267 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2011年 / 80卷 / 02期
关键词
Breast cancer; Tomotherapy; Treatment reproducibility; Image guidance; Breast volume; HELICAL TOMOTHERAPY; CONFORMAL RADIOTHERAPY; LUNG-CANCER; IRRADIATION; GUIDANCE;
D O I
10.1016/j.ijrobp.2010.02.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine whether the volume of a patient's breast is correlated with reliable daily setup in treatment cif breast cancer with a helical tomotherapy treatment unit. Methods and Materials: Thirty-six consecutive patients with breast cancer were treated on a helical tomotherapy unit. During simulation, kilovoltage CT images were obtained for treatment planning. These were fused with daily megavoltage CT scans, and after setup based on skin marks and laser alignment the necessary shifts were carried out. The magnitude of daily shifts (in millimeters) was retrospectively obtained from the daily image fusions, and the breast volume was obtained from the treatment plan. A total of 873 fusion scans were reviewed. Random error for absolute and directional daily shifts was evaluated for correlation to volume. Variation over time was also evaluated. Results: Mean (SD) random shift for all patients in the lateral, longitudinal, and vertical directions was 2.7 (2.0), 3.1 (1.5), and 3.2 (2.6) mm, respectively. Mean (SD) absolute distance shifted was 6.0 (3.5) mm. There was no significant correlation between mean absolute or mean directional daily shift and breast volume (0.08, 0.08, 0.22, and 0.07, respectively). There was no correlation between setup variation and time. Conclusions: In this cohort, there was no correlation between breast volume and degree of daily shift. There was no correlation between time course and setup variation. Therefore, setup variation does not improve or degrade with repeated treatment setups. (C) 2011 Elsevier Inc.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 15 条
  • [1] MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER
    BIJHOLD, J
    LEBESQUE, JV
    HART, AAM
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) : 261 - 271
  • [2] Helical tomotherapy for locoregional irradiation including the internal mammary chain in left-sided breast cancer: Dosimetric evaluation
    Caudrelier, Jean-Michel
    Morgan, Scott C.
    Montgomery, Lynn
    Lacelle, Manon
    Nyiri, Balazs
    MacPherson, Miller
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 99 - 105
  • [3] Setup variations in radiotherapy of esophageal cancer: Evaluation by daily megavoltage computed tomographic localization
    Chen, Yi-Jen
    Han, Chunhui
    Liu, An
    Schultheiss, Timothy E.
    Kernstine, Kemp H.
    Shibata, Stephen
    Vora, Nayana L.
    Pezner, Richard D.
    Wong, Jeffrey Y. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (05): : 1537 - 1545
  • [4] de Koste JRV, 2003, INT J RADIAT ONCOL, V55, P804, DOI 10.1016/S0630-3016(02)04285-2
  • [5] Dosimetric consequences of uncorrected setup errors in helical Tomotherapy treatments of breast-cancer patients
    Goddu, S. Murty
    Yaddanapudi, Sridhar
    Pechenaya, Olga L.
    Chaudhari, Summer R.
    Klein, Eric E.
    Khullar, Divya
    El Naqa, Issam
    Mutic, Sasa
    Wahab, Sasha
    Santanam, Lakshmi
    Zoberi, Imran
    Low, Daniel A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 64 - 70
  • [6] HELICAL TOMOTHERAPY PLANNING FOR LEFT-SIDED BREAST CANCER PATIENTS WITH POSITIVE LYMPH NODES: COMPARISON TO CONVENTIONAL MULTIPORT BREAST TECHNIQUE
    Goddu, S. Murty
    Chaudhari, Summer
    Mamalui-Hunter, Maria
    Pechenaya, Olga L.
    Pratt, David
    Mutic, Sasa
    Zoberi, Imran
    Jeswani, Sam
    Powell, Simon N.
    Low, Daniel A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (04): : 1243 - 1251
  • [7] Initial experience with megavoltage (MV) CT guidance for daily prostate alignments
    Langen, KM
    Zhang, YS
    Andrews, RD
    Hurley, ME
    Meeks, SL
    Poole, DO
    Willoughby, TR
    Kupelian, PA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05): : 1517 - 1524
  • [8] Image guidance for precise conformal radiotherapy
    Mackie, TR
    Kapatoes, J
    Ruchala, K
    Lu, WG
    Wu, C
    Olivera, G
    Forrest, L
    Tome, W
    Welsh, J
    Jeraj, R
    Harari, P
    Reckwerdt, P
    Paliwal, B
    Ritter, M
    Keller, H
    Fowler, J
    Mehta, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 89 - 105
  • [9] TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY
    MACKIE, TR
    HOLMES, T
    SWERDLOFF, S
    RECKWERDT, P
    DEASY, JO
    YANG, J
    PALIWAL, B
    KINSELLA, T
    [J]. MEDICAL PHYSICS, 1993, 20 (06) : 1709 - 1719
  • [10] Early Experience of Tomotherapy-based Intensity-modulated Radiotherapy for Breast Cancer Treatment
    O'Donnell, H.
    Cooke, K.
    Walsh, N.
    Plowman, P. N.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (04) : 294 - 301