Detection of Coronary Artery Anomalies in Infants and Young Children with Congenital Heart Disease by Using MR Imaging

被引:69
作者
Tangcharoen, Tarinee [1 ]
Bell, Aaron [1 ]
Hegde, Sanjeet [1 ]
Hussain, Tarique [1 ]
Beerbaum, Philipp [1 ]
Schaeffter, Tobias [1 ]
Razavi, Reza [1 ]
Botnar, Rene M. [1 ]
Greil, Gerald F. [1 ]
机构
[1] Kings Coll London, Rayne Inst, Guys & St Thomas Hosp, Div Imaging Sci, London SE1 7EH, England
关键词
MAGNETIC-RESONANCE ANGIOGRAPHY; KAWASAKI-DISEASE; IDENTIFICATION; TETRALOGY; FALLOT; MORPHOLOGY; DIAGNOSIS; PATTERNS; ANATOMY;
D O I
10.1148/radiol.10100828
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility and accuracy of magnetic resonance (MR) coronary angiography for the detection of coronary artery anomalies in infants and children by using surgical findings as a reference. Materials and Methods: The data analysis was approved by the institutional review board. One hundred children with congenital heart disease underwent MR coronary angiography while under general anesthesia (mean age +/- standard deviation, 3.9 years +/- 3; age range, 0.2-11 years). A navigator-gated, T2-prepared, three-dimensional steady-state free precession whole-heart protocol (isotropic voxel size, 1.0-1.3 mm(3); mean imaging time, 4.6 minutes +/- 1.2; mean navigator efficiency, 70%; 3-mm gating window) was used after injection of gadopentetate dimeglumine. The cardiac rest period (end systole or middiastole) and acquisition window were prospectively assessed for each patient. Coronary artery image quality (score of 0 [nondiagnostic] to 4 [excellent]), vessel sharpness, and coronary artery anomalies were assessed by two observers. Surgery was performed in 58 patients, and those findings were used to define accuracy. Variables were assessed between age groups by using either analysis of variance or Kruskal-Wallis tests. Results: Diagnostic image quality (score, >= 1 for all coronary artery segments) was obtained in 46 of the 58 patients (79%) who underwent surgery. The origin and course of the coronary artery anatomy depicted with MR imaging was confirmed at surgery in all 46 patients-including the four (9%) with substantial coronary artery anomalies. Diagnostic-quality images were obtained in 84 of the 100 patients. The rate of success improved significantly when patients were older than 4 months (88% for patients > 4 months vs 17% for patients <= 4 months, P < .001). Conclusion: Improved whole-heart MR coronary angiography enables accurate detection of abnormal origin and course of the coronary artery system even in very young patients with congenital heart disease. (C) RSNA, 2011
引用
收藏
页码:240 / 247
页数:8
相关论文
共 35 条
[1]   Coronary Anomalies Assessed by Whole-Heart Isotropic 3D Magnetic Resonance Imaging for Cardiac Morphology in Congenital Heart Disease [J].
Beerbaum, Philipp ;
Sarikouch, Samir ;
Laser, Kai-Thorsten ;
Greil, Gerald ;
Burchert, Wolfgang ;
Koerperich, Hermann .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) :320-327
[2]  
Bergersen Lisa, 2008, Congenit Heart Dis, V3, P230, DOI 10.1111/j.1747-0803.2008.00196.x
[3]   Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent [J].
Bi, Xiaoming ;
Carr, James C. ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) :1-7
[4]  
CARVALHO JS, 1993, BRIT HEART J, V70, P75
[5]   ASSOCIATED CORONARY AND CARDIAC ANOMALIES IN THE TETRALOGY OF FALLOT - AN ANGIOGRAPHIC STUDY [J].
DABIZZI, RP ;
TEODORI, G ;
BARLETTA, GA ;
CAPRIOLI, G ;
BALDRIGHI, G ;
BALDRIGHI, V .
EUROPEAN HEART JOURNAL, 1990, 11 (08) :692-704
[6]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[7]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[8]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[9]  
2-9
[10]  
Geva TKJ., 2001, Cardiology, P7