Live endothelial cells on plasma-nitrided and oxidized titanium: An approach for evaluating biocompatibility

被引:8
作者
Braz, Janine Karla F. S. [1 ,2 ]
Martins, Gabriel Moura [1 ]
Morales, Nicole [3 ]
Naulin, Pamela [3 ]
Fuentes, Christian [3 ]
Barrera, Nelson P. [3 ]
Vitoriano, Jussier O. [4 ]
Rocha, Hugo A. O. [5 ]
Oliveira, Moacir F. [1 ]
Alves Jr, Clodomiro [4 ]
Moura, Carlos Eduardo B. [1 ]
机构
[1] Univ Fed Rural Semi Arido, Dept Anim Sci, Mossoro, Brazil
[2] Univ Fed Rio Grande do Norte, Escola Multicampi Ciencias Med Rio Grande do Nort, Natal, RN, Brazil
[3] Pontificia Univ Catolica Chile, Fac Biol Sci, Dept Physiol, Santiago, Chile
[4] Univ Fed Rio Grande do Norte, Lab Plasma Aplicado Agr Saude & Meio Ambiente, Natal, RN, Brazil
[5] Univ Fed Rio Grande do Norte, Dept Biochem, Natal, RN, Brazil
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2020年 / 113卷
关键词
Implants; Nitriding; Oxidation; Biocompatibility; Viscoelastic properties; ATOMIC-FORCE MICROSCOPY; SURFACE-TREATMENT; GENE-EXPRESSION; IN-VITRO; MECHANOTRANSDUCTION; PROLIFERATION; STIFFNESS; BEHAVIOR; MUSCLE;
D O I
10.1016/j.msec.2020.111014
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
We evaluated the effects of titanium plasma nitriding and oxidation on live endothelial cell viscoelasticity. For this, mechanically polished titanium surfaces and two surfaces treated by planar cathode discharge in nitriding (36N(2) and 24H(2)) and oxidant (36O(2) and 24H(2)). Surfaces were characterized regarding wettability, roughness and chemical composition. Rabbit aortic endothelial cells (RAECs) were cultured on the titanium surfaces. Cell morphology, viability and viscoelasticity were evaluated by scanning electron microscopy (SEM), methyl thiazolyl tetrazolium (MTT) assay and atomic force microscopy (AFM), respectively. Grazing Incidence X-ray Diffraction confirmed the presence of TiN0,26 on the surface (grazing angle theta 1 degrees) of the nitrided samples, decreasing with depth. On the oxidized surface had the formation of TiO3 on the material surface (Theta 1 degrees) and in the deeper layers was noted, with a marked presence of Ti (Theta 3 degrees). Both plasma treatments increased surface roughness and they are hydrophilic (angle< 90 degrees). However, oxidation led to a more hydrophilic titanium surface (66.59 degrees +/- 3.65 vs. 76.88 degrees +/- 2.68; p = 0.001) due to titanium oxide films in their stoichiometric varieties (Ti3O, TiO2, Ti6O), especially Ti3O. Despite focal adhesion on the surfaces, viability was different after 24 h, as cell viability on the oxidized surface was higher than on the nitrided surface (9.1 x 10(3) vs. 4.5 x 10(3)cells; p < 0.05). This can be explained by analyzing the viscoelastic property of the cellular cytoskeleton (nuclear and peripheral) by AFM. Surface oxidation significantly increased RAECs viscoelasticity at cell periphery, in comparison to the nucleus (2.36 +/- 0.3 vs. 1.5 +/- 0.4; p < 0.05), and to the RAECs periphery in contact with nitrided surfaces (1.36 +/- 0.7; p < 0.05) and polished surfaces (1.55 +/- 0.6; p < 0.05). Taken together, our results have shown that titanium plasma treatment directly increased cell viscoelasticity via surface oxidation, and this mechanobiological property subsequently increased biocompatibility.
引用
收藏
页数:9
相关论文
共 53 条
[1]   The effect of plasma surface treatment on the bioactivity of titanium implant materials (in vitro) [J].
Abdelrahim, Ramy A. ;
Badr, Nadia A. ;
Baroudi, Kusai .
JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (01) :15-21
[2]  
Alves C., 2013, Encyclopedia of Tribology, P402, DOI [10.1007/978-0-387-92897-5_716, DOI 10.1007/978-0-387-92897-5_716]
[3]  
Alves C. Jr., 2006, Surface & Coatings Technology, V200, P3657, DOI 10.1016/j.surfcoat.2005.08.005
[4]   Proliferation, behavior, and cytokine gene expression of human umbilical vascular endothelial cells in response to different titanium surfaces [J].
An, Na ;
Schedle, Andreas ;
Wieland, Marco ;
Andrukhov, Oleh ;
Matejka, Michael ;
Rausch-Fan, Xiaohui .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 93A (01) :364-372
[5]  
Azeloglu EU, 2011, METHODS MOL BIOL, V736, P303, DOI 10.1007/978-1-61779-105-5_19
[6]   MC3T3-E1 Cells Behavior on Surfaces Bombarded by Argon Ions in Planar Cathode Discharge [J].
Bezerra Moura, Carlos Eduardo ;
Silva, Naisandra Bezerra ;
Sa, Juliana Carvalho ;
Cavalcanti Junior, Geraldo Barroso ;
Batistuzzo de Medeiros, Silvia Regina ;
Oliveira Rocha, Hugo Alexandre ;
Papa, Paula Carvalho ;
Alves, Clodomiro, Jr. .
ARTIFICIAL ORGANS, 2016, 40 (05) :497-504
[7]   Cardiovascular stents: overview, evolution, and next generation [J].
Borhani S. ;
Hassanajili S. ;
Ahmadi Tafti S.H. ;
Rabbani S. .
Progress in Biomaterials, 2018, 7 (3) :175-205
[8]  
Braz J, 2019, RESBCAL, V7, P56
[9]   Plasma nitriding under low temperature improves the endothelial cell biocompatibility of 316L stainless steel [J].
Braz, Janine K. F. S. ;
Martins, Gabriel M. ;
Sabino, Vladimir ;
Vitoriano, Jussier O. ;
Barboza, Carlos Augusto G. ;
Soares, Ana Katarina M. C. ;
Rocha, Hugo A. O. ;
Oliveira, Moacir. F. ;
Alves Junior, Clodomiro ;
Moura, Carlos Eduardo B. .
BIOTECHNOLOGY LETTERS, 2019, 41 (4-5) :503-510
[10]   Endothelial cell reaction on a biological material [J].
Breithaupt-Faloppa, AC ;
Kleinheinz, J ;
Crivello, O .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 76B (01) :49-55