Scintillator selection for MR-compatible gamma detectors

被引:59
作者
Yamamoto, S [1 ]
Kuroda, K
Senda, M
机构
[1] Kobe City Coll Technol, Nishi Ku, Kobe, Hyogo 6512194, Japan
[2] Inst Biomed Res & Innovat, Chuo Ku, Kobe, Hyogo 6500047, Japan
关键词
artifacts; MRI; scintillators; susceptibility;
D O I
10.1109/TNS.2003.817375
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We investigated the magnetic susceptibility of several scintillators to select the best material for MR-compatible gamma detectors. NaI(Tl) in an At container, NaI(Tl) in a Cu container and CsI(Tl) are candidates for MR-compatible gamma probes, imaging probes or SPECT, while BGO, LSO, LGSO, and GSO are the candidates for MR-compatible PET. In addition, we investigated image artifacts and distortion by scanning these scintillators with an MR-scanner. Results show that the magnetic susceptibility of NaI(TI), CsI(TI), BGO, and LSO showed similarities to that of human tissue. Of these scintillators, NaI(TI) in a Cu container showed the closest to that of susceptibility to human tissue and fewest artifacts on the MRI image. It is a good material for an MR-compatible gamma probe or imaging probe as well as SPECT. For MR-compatible PET, BGO, and LSO showed similar susceptibility to that of human tissue and small artifacts on the MRI images. However, LGSO and GSO showed much greater susceptibility than human tissue, and produced significant artifacts and distortion in the MRI images due to the presence of gadolinium (Gd) in these scintillators.
引用
收藏
页码:1683 / 1685
页数:3
相关论文
共 7 条
[1]   A system to obtain radiotracer uptake data simultaneously with NMR spectra in a high field magnet [J].
Buchanan, M ;
Marsden, PK ;
Mielke, CH ;
Garlick, PB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :2044-2048
[2]  
Hoffmann-Richter U, 1999, PSYCHIAT PRAX, V26, P8
[3]  
JALESZ FA, 1992, INVEST RADIOL, V27, P326
[4]  
Schneck JF, 1996, MED PHYS, V23, P815
[5]   Development of a PET detector system compatible with MRI/NMR systems [J].
Shao, Y ;
Cherry, SR ;
Farahani, K ;
Slates, R ;
Silverman, RW ;
Meadors, K ;
Bowery, A ;
Siegel, S ;
Marsden, PK ;
Garlick, PB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1167-1171
[6]   Simultaneous PET and MR imaging [J].
Shao, YP ;
Cherry, SR ;
Farahani, K ;
Meadors, K ;
Siegel, S ;
Silverman, RW ;
Marsden, PK .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (10) :1965-1970
[7]   A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner [J].
Slates, RB ;
Farahani, K ;
Shao, YP ;
Marsden, PK ;
Taylor, J ;
Summers, PE ;
Williams, S ;
Beech, J ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08) :2015-2027