Effect of reference conditions on flow rate, modifier fraction and retention in supercritical fluid chromatography

被引:8
|
作者
De Pauw, Ruben [1 ]
Shoykhet , Konstantin [2 ]
Desmet, Gert [1 ]
Broeckhoven, Ken [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn CHIS IR, Pl Laan 2, B-1050 Brussels, Belgium
[2] Agilent Technol Europe, Hewlett Packard Str 8, D-76337 Waldbronn, Germany
关键词
Supercritical fluid chromatography; Volume; Mass; Flow rate; Retention; Reference conditions; GRADIENT ELUTION; DESIGNING OPERATIONS; ISOPYCNIC PLOTS; MOBILE-PHASE; LIQUID-CHROMATOGRAPHY; CONSTANT-PRESSURE; DEAD VOLUME; METHANOL; DENSITY; MASS;
D O I
10.1016/j.chroma.2016.06.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When using compressible mobile phases such as fluidic CO2, the density, the volumetric flow rates and volumetric fractions are pressure dependent. The pressure and temperature definition of these volumetric parameters (referred to as the reference conditions) may alter between systems, manufacturers and operating conditions. A supercritical fluid chromatography system was modified to operate in two modes with different definition of the eluent delivery parameters, referred to as fixed and variable mode. For the variable mode, the volumetric parameters are defined with reference to the pump operating pressure and actual pump head temperature. These conditions may vary when, e.g. changing the column length, permeability, flow rate, etc. and are thus variable reference conditions. For the fixed mode, the reference conditions were set at 150 bar and 30 degrees C, resulting in a mass flow rate and mass fraction of modifier definition which is independent of the operation conditions. For the variable mode, the mass flow rate of carbon dioxide increases with system pump operating pressure, decreasing the fraction of modifier. Comparing the void times and retention factor shows that the deviation between the two modes is almost independent of modifier percentage, but depends on the operating pressure. Recalculating the set volumetric fraction of modifier to the mass fraction results in the same retention behaviour for both modes. This shows that retention in SFC can be best modelled using the mass fraction of modifier. The fixed mode also simplifies method scaling as it only requires matching average column pressure. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [1] Unusual effect of flow rate on retention in analytical supercritical fluid chromatography exemplified by polyethylene glycol separation
    Kostenko, Mikhail O.
    Pokrovskiy, Oleg, I
    Zakhodyaeva, Yulia A.
    Voshkin, Andrey A.
    Lunin, Valery V.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1610
  • [2] Occurrence of turbulent flow conditions in supercritical fluid chromatography
    De Pauw, Ruben
    Choikhet, Konstantin
    Desmet, Gert
    Broeckhoven, Ken
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1361 : 277 - 285
  • [3] Modifier adsorption in supercritical fluid chromatography onto silica surface
    Vajda, Peter
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1305 : 293 - 299
  • [4] LOW-FLOW RATE MODIFIER ADDITION IN PACKED CAPILLARY COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY
    IBANEZ, E
    LI, WB
    MALIK, A
    LEE, ML
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (09): : 559 - 563
  • [5] Effect of density on kinetic performance in supercritical fluid chromatography with methanol modified carbon dioxide
    Berger, Terry A.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1564 : 188 - 198
  • [6] A review of fraction collection technology for supercritical fluid chromatography
    Kaplitz, Alexander S.
    Berger, Terry A.
    Berger, Blair K.
    Schug, Kevin A.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 151
  • [7] Determination of the average volumetric flow rate in supercritical fluid chromatography
    Vajda, Peter
    Stankovich, Joseph J.
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1339 : 168 - 173
  • [8] Effect of the thermal environment on the efficiency of packed columns in supercritical fluid chromatography
    Zauner, Jordan
    Lusk, Ryan
    Koski, Steven
    Poe, Donald P.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 : 149 - 157
  • [9] Effects of pressure drop, particle size and thermal conditions on retention and efficiency in supercritical fluid chromatography
    Poe, Donald P.
    Schroden, Jonathan J.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (45) : 7915 - 7926
  • [10] Evaluation of co-solvent fraction, pressure and temperature effects in analytical and preparative supercritical fluid chromatography
    Asberg, Dennis
    Enmark, Martin
    Samuelsson, Jorgen
    Fornstedt, Torgny
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1374 : 254 - 260