Acute quadriceps tendon rupture repaired by suture anchors: Outcomes at 7 years' follow-up in 25 cases

被引:25
作者
Brossard, P. [1 ]
Le Roux, G. [1 ]
Vasse, B. [1 ]
机构
[1] Ctr Hosp La Rochell, Serv Orthopedie & Traumatol, F-17019 La Rochell, France
[2] 18 Rue Belliniere, F-49800 Trelaze, France
关键词
Quadriceps tendon; Rupture; Anchor; Outcomes; Radiographic evaluation; EXTENSOR MECHANISM; KNEE; APPARATUS; FIXATION;
D O I
10.1016/j.otsr.2017.02.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Acute quadriceps tendon rupture is rare. The gold-standard repair technique is transosseous patellar suture. Biomechanical studies have validated the use of anchors as an alternative. The present study sought to report long-term clinical and radiological results in a series of acute quadriceps tendon rupture repaired with anchors. The study hypothesis was that results are comparable to those of the gold-standard technique. Methods: A retrospective continuous study included 25 knees with acute quadriceps tendon rupture, operated on by a single surgeon between 2007 and 2013: 22 patients; 17 males, 5 females; mean age, 64 years (range: 52-87 years). Modified Bunnell suture was performed, using either 2 anchors (19 knees) or 3 anchors (6 knees). Anchors were positioned under 20 degrees flexion. The factors studied were: active range of motion, muscle strength, patient satisfaction, Lysholm score, return to work, and the radiological behavior of the anchors. Results: At a mean follow-up of 7 years (range: 3-9 years), all but 1 patient had 0 degrees active extension. Mean active flexion was 128 degrees (range: 110-150 degrees), and mean muscle strength was 4.9/5. Mean Lysholm score was 92. Subjective results proved satisfactory or very satisfactory in 23 cases. Working patients returned to work at a mean 4.2 months. There were no cases of anchor migration or of re-rupture. One poorly tolerated anchor was ablated at 2 years, without functional impact. Conclusion: Outcomes with anchors were comparable to those of the gold-standard technique. Anchors allow immediate rehabilitation, without risk of anchor migration. The technique provided satisfactory functional recovery. (C) 2017 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 38 条
[1]   Acute quadriceps tendon ruptures: A series of 50 knees with an average follow-up of more than 6 years [J].
Boudissa, M. ;
Roudet, A. ;
Rubens-Duval, B. ;
Chaussard, C. ;
Saragaglia, D. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (02) :213-216
[2]   The Use of Suture Anchors to Repair the Ruptured Quadriceps Tendon [J].
Bushnell, Brandon D. ;
Whitener, George B. ;
Rubright, James H. ;
Creighton, R. Alexander ;
Logel, Kevin J. ;
Wood, Mark L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (06) :407-413
[3]   Repair of patellar tendon rupture with suture anchors [J].
Capiola, David ;
Re, Louis .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (08) :906.e1-906.e4
[4]   Clinical outcomes after repair of quadriceps tendon rupture: A systematic review [J].
Ciriello, Vincenzo ;
Gudipati, Suribabu ;
Tosounidis, Theodoros ;
Soucacos, P. N. ;
Giannoudis, Peter V. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (11) :1931-1938
[5]   The epidemiology of musculoskeletal tendinous and ligamentous injuries [J].
Clayton, Robert A. E. ;
Court-Brown, Charles M. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (12) :1338-1344
[6]  
De Baere T, 2002, Acta Orthop Belg, V68, P146
[7]   Patellar Stress Fracture After Transosseous Extensor Mechanism Repair Report of 3 Cases [J].
Gregory, James M. ;
Sherman, Seth L. ;
Mather, Richard ;
Bach, Bernard R., Jr. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (07) :1668-1672
[8]   Suture Anchor Repair of Quadriceps Tendon Rupture [J].
Harris, Joshua D. ;
Abrams, Geoffrey D. ;
Yanke, Adam B. ;
Hellman, Michael D. ;
Erickson, Brandon J. ;
Bach, Bernard R., Jr. .
ORTHOPEDICS, 2014, 37 (03) :183-186
[9]   Quadriceps Tenon Rupture: A Biomechanical Comparison of Transosseous Equivalent Double-Row Suture Anchor Versus Transosseous Tunnel Repair [J].
Hart, Nathan D. ;
Wallace, Matthew K. ;
Scovell, J. Field ;
Krupp, Ryan J. ;
Cook, Chad ;
Wyland, Douglas J. .
JOURNAL OF KNEE SURGERY, 2012, 25 (04) :335-339
[10]  
Ilan Doron I, 2003, J Am Acad Orthop Surg, V11, P192