Plastic scintillation dosimetry: optimization of light collection efficiency

被引:51
作者
Beddar, AS [1 ]
Law, S
Suchowerska, N
Mackie, R
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX USA
[2] Univ Sydney, Australian Photon CRC, Opt Fibre Technol Ctr, Sydney, NSW, Australia
[3] Royal Prince Alfred Hosp, Dept Radiat Oncol, Sydney, NSW, Australia
[4] Univ Sydney, Sydney, NSW 2006, Australia
[5] Univ Wisconsin, Sch Med, Dept Phys Med, Madison, WI USA
关键词
D O I
10.1088/0031-9155/48/9/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Practical contemporary radiotherapy dosimetry systems used for dose measurement and verification are ionization chambers (which typically have at least a 0.1 cm(3) air cavity volume), thermoluminescent dosimeters (TLDs) and silicon diodes. However, during the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, due to their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The objectives of this study are to identify the factors preventing this new technology from realizing its full potential in commercial applications. A definition of signal to noise ratio (S/N) will be proposed for this category of detectors. In doing so the S/N ratio for an early prototype design has been calculated and/or measured. Criteria to optimize the response and sensitivity of this category of detectors are presented.
引用
收藏
页码:1141 / 1152
页数:12
相关论文
共 22 条
[1]   Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry [J].
Arnfield, MR ;
Gaballa, HE ;
Zwicker, RD ;
Islam, Q ;
SchmidtUllrich, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :2077-2084
[2]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[3]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[4]   A NEW SCINTILLATOR DETECTOR SYSTEM FOR THE QUALITY ASSURANCE OF CO-60 AND HIGH-ENERGY THERAPY MACHINES [J].
BEDDAR, AS .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :253-263
[5]   A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery [J].
Beddar, AS ;
Kinsella, TJ ;
Ikhlef, A ;
Sibata, CH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :924-928
[6]   CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[7]  
BEDDAR AS, 1988, P SOC PHOTO-OPT INS, V992, P170
[8]  
BEDDAR AS, 1995, RADIOTHER ONCOL S1, V37, P44
[9]  
BEDDAR AS, 1992, MED PHYS, V19, P790
[10]  
BEDDAR AS, 1988, ESI PUBLICATIONS, P146